259 research outputs found
Maximum Induced Subgraph of an Augmented Cube
Let maxζG(m) denote the maximum number of edges in a subgraph of graph G induced by m nodes. The n-dimensional augmented cube, denoted as AQn, a variation of the hypercube, possesses some properties superior to those of the hypercube. We study the cases when G is the augmented cube AQn
Maximum Induced Subgraph of an Augmented Cube
Let maxζG(m) denote the maximum number of edges in a subgraph of graph G induced by m nodes. The n-dimensional augmented cube, denoted as AQn, a variation of the hypercube, possesses some properties superior to those of the hypercube. We study the cases when G is the augmented cube AQn
A Microcantilever-based Gas Flow Sensor for Flow Rate and Direction Detection
The purpose of this paper is to apply characteristics of residual stress that
causes cantilever beams to bend for manufacturing a micro-structured gas flow
sensor. This study uses a silicon wafer deposited silicon nitride layers,
reassembled the gas flow sensor with four cantilever beams that perpendicular
to each other and manufactured piezoresistive structure on each
micro-cantilever by MEMS technologies, respectively. When the cantilever beams
are formed after etching the silicon wafer, it bends up a little due to the
released residual stress induced in the previous fabrication process. As air
flows through the sensor upstream and downstream beam deformation was made,
thus the airflow direction can be determined through comparing the resistance
variation between different cantilever beams. The flow rate can also be
measured by calculating the total resistance variations on the four
cantilevers.Comment: Submitted on behalf of EDA Publishing Association
(http://irevues.inist.fr/handle/2042/16838
Design and Analysis of Impedance Pumps Utilizing Electromagnetic Actuation
This study designs and analyzes an impedance pump utilizing an electromagnetic actuator. The pump is designed to have three major components, namely a lower glass substrate patterned with a copper micro-coil, a microchannel, and an upper glass cover plate attached a magnetic PDMS diaphragm. When a current is passed through the micro-coil, an electromagnetic force is established between the coil and the magnetic diaphragm. The resulting deflection of the PDMS diaphragm creates an acoustic impedance mismatch within the microchannel, which results in a net flow. In performing the analysis, simulated models of the magnetic field, the diaphragm displacement and the flow rate are developed using Ansoft/Maxwell3D, ANSYS FEA and FLUENT 6.3 CFD software, respectively. Overall, the simulated results reveal that a net flow rate of 52.8 μL/min can be obtained using a diaphragm displacement of 31.5 μm induced by a micro-coil input current of 0.5 A. The impedance pump proposed in this study provides a valuable contribution to the ongoing development of Lab-on-Chips (LoCs) systems
Fever Screening at Airports and Imported Dengue
Airport fever screening in Taiwan, July 2003–June 2004, identified 40 confirmed dengue cases. Results obtained by capture immunoglobulin (Ig) M and IgG enzyme-linked immunoassay, real time 1-step polymerase chain reaction, and virus isolation showed that 33 (82.5%) of 40 patients were viremic. Airport fever screening can thus quickly identify imported dengue cases
Perforated Sigmoid Colon Cancer within an Irreducible Inguinal Hernia: a Case Report
A perforated sigmoid colon cancer within an inguinal hernia is extremely rare. This unexpected finding is usually discovered during surgery and causes an unavoidable septic evolution. Here, we describe the case of an 84-year-old man who presented with fever, abdominal distension, and a painful, enlarged, left scrotum. A CT showed a left, incarcerated, inguinal hernia containing a perforated sigmoid adenocarcinoma (which was confirmed by histopathology). The possibility of an irreducible inguinal hernia in association with perforated sigmoid colon cancer should be considered in the array of diagnoses. A pre-operative CT scan would be helpful in facilitating an accurate diagnosis
A novel randomly textured phosphor structure for highly efficient white light-emitting diodes
We have successfully demonstrated the enhanced luminous flux and lumen efficiency in white light-emitting diodes by the randomly textured phosphor structure. The textured phosphor structure was fabricated by a simple imprinting technique, which does not need an expensive dry-etching machine or a complex patterned definition. The textured phosphor structure increases luminous flux by 5.4% and 2.5% at a driving current of 120 mA, compared with the flat phosphor and half-spherical lens structures, respectively. The increment was due to the scattering of textured surface and also the phosphor particles, leading to the enhancement of utilization efficiency of blue light. Furthermore, the textured phosphor structure has a larger view angle at the full width at half maximum (87°) than the reference LEDs
- …