26 research outputs found
Fracture precursor phenomena in marble specimens under uniaxial compression by means of Acoustic Emission data
Marble specimens are subjected to a specially designed stepwise loading protocol, in an attempt to detect fracture precursor phenomena taking advantage of Acoustic Emission (AE) data. The analysis is carried out in terms of the number of acoustic hits recorded and the time evolution of the improved b-value (Ib-value), the cumulative energy of the acoustic signals and the F-function. During the stage of increasing load, intense acoustic activity is detected as the corresponding stress reaches the transitional phase from the linear to the nonlinear mechanical response of the material. When the stress is stabilized at levels exceeding 95% of the material’s compressive strength, the acoustic activity is drastically reduced. During the first seconds of the stress stabilization stage the reduction follows an exponential law. Special attention is paid to the phases, where the occurrence of AE hits shows a strong increase. During these phases acoustic signals of low frequency and high RA are recorded, indicating that the micro-cracking process is of shear rather than of opening mode
Correlation between the electric and acoustic signals emitted during compression of brittle materials
An experimental protocol is described including a series of uniaxial compression tests of three brittle materials (marble, mortar and glass). The Acoustic Emission (AE) technique and the Pressure Stimulated Currents (PSC) one are used since the recordings of both techniques are strongly related to the formation of cracking in brittle materials. In the present paper, the correlation of these techniques is investigated, which is finally proven to be very satisfactory
The critical influence of some “tiny” geometrical details on the stress field in a Brazilian Disc with a central notch of finite width and length
The role of some geometrical characteristics of the notches machined in circular discs, in order to determine the mode-I fracture toughness of brittle materials, is discussed. The study is implemented both analytically and numerically. For the analytic study advantage is taken of a recently introduced solution for the stress- and displacement-fields developed in a finite disc with a central notch of finite width and length and rounded corners. The variation of the stresses along strategic loci and the deformation of the perimeter of the notch obtained analytically are used for the calibration/validation of a flexible numerical model, which is then used for a parametric investigation of the role of geometrical features of the notched disc (thickness of the disc, length and width of the notch, radius of the rounded corners of the notch). It is concluded that the role of the width of the notch is of critical importance. Both the analytic and the numerical studies indicate definitely that ignoring the accurate geometric shape of the notch leads to erroneous results concerning the actual stress field around the crown of the notch. Therefore, it is possible that misleading values of the fracture toughness of the material of the disc may be obtained
Damage evolution in marble under uniaxial compression monitored by Pressure Stimulated Currents and Acoustic Emissions
The spatiotemporal evolution of damage in marble specimens under uniaxial compression is monitored using Pressure Stimulated Currents (PSCs) and Acoustic Emissions (AEs). The novelty of the study is the use of an integrated grid of sensors (instead of a single pair of electrodes) to detect the weak electrical signals, emitted during loading. The use of such a grid of sensors does indeed enhance the capabilities of the PSC technique providing valuable information about the initiation and propagation of micro-fracturing at the interior of the specimens. The experimental results indicate that both the improved b-value of the AE hits and the energy of the PSCs offer information about the proximity of the applied stress to that causing fracture. It is thus concluded that both quantities could be considered as pre-failure indicators
Assessing structural integrity of non-homogeneous systems by means of Acoustic Emissions and Non-Extensive Statistical Mechanics
Taking advantage of the interevent time intervals, namely the time intervals between two successive acoustic events recorded during mechanical loading of structural elements, it is attempted to detect indices warning about upcoming failure. The innovative aspect of the study is that the analysis is implemented in the frame of Non-Extensive Statistical Mechanics, a discipline founded on a class of entropies violating the additivity principle, which is the cornerstone of the Boltzmann-Gibbs Statistical Mechanics. The specimens used for the experiments were marble blocks simulating either fragmented and restored epistyles or mutually interconnected intact epistyles of the Parthenon Temple on the Acropolis of Athens. The specimens consisted of three mate�rials (marble, metallic connectors and cementitious pastes) exhibiting, thus, a strongly non-homogeneous nature. The entropic index, i.e., the parameter quantifying the degree of non-additivity, was used for the analysis of the ex�pe�rimental data. The results were considered in juxtaposition to the re�spective ones from experimental protocols with specimens of macroscopically homo�geneous nature. It was concluded that the temporal evolution of the entropic index provides very good insight into the level of damage ac�cumu�lated in the loaded structure, independently of whether the structure is homogeneous or not, providing an interesting pre-failure indicato
Acoustic Emissions versus Pressure Stimulated Currents during bending of restored marble epistyles: Preliminary results
The efficiency of two modern sensing techniques, namely the “Acoustic Emissions” and the “Pressure Stimulated Currents” ones, when they are used as Continuous Structural Health Monitoring tools, is assessed experimentally. The protocol includes multi-point bending of an accurate copy of a fractured marble epistyle of the Parthenon’s Temple on the Acropolis of Athens, under a scale of 1:3. The integrity of the epistyle is restored with three pairs of bolted titanium bars, according to the pioneering technique developed by the scientists of the “Committee for the Conservation of the Acropolis Monuments”. The data provided by the above techniques are considered in juxtaposition to each other and also in comparison to data provided by the “Digital Image Correlation” technique. It is concluded that, at least from a qualitative point of view, the data of all three techniques are in good mutual agreement. Combined exploitation of the various sets of experimental data enlightens interesting aspects concerning the succession of failure mechanisms activated during the loading procedure, revealing the critical role of the internal interfaces characterizing the restored epistyle. Moreover it is definitely indicated that both the “Acoustic Emissions” and the “Pressure Stimulated Currents” techniques provide clear signs of upcoming failure well before macroscopically visible damages are detected at the external surface of the specimen
A Multi-Element Detector System for Intelligent Imaging: I-ImaS
I-ImaS is a European project aiming to produce new, intelligent x-ray imaging systems using novel APS sensors to create optimal diagnostic images. Initial systems concentrate on mammography and encephalography. Later development will yield systems for other types of radiography such as industrial QA and homeland security.
The I-ImaS system intelligence, due to APS technology and FPGAs, allows real-time analysis of data during image acquisition, giving the capability to build a truly adaptive imaging system with the potential to create images with maximum diagnostic information within given dose constraints.
A companion paper deals with the DAQ system and preliminary characterization. This paper considers the laboratory x-ray characterization of the detector elements of the I-ImaS system. The characterization of the sensors when tiled to form a strip detector will be discussed, along with the appropriate correction techniques formulated to take into account the misalignments between individual sensors within the array.
Preliminary results show that the detectors have sufficient performance to be used successfully in the initial mammographic and encephalographic I-ImaS systems under construction and this paper will further discuss the testing of these systems and the iterative processes used for intelligence upgrade in order to obtain the optimal algorithms and setting
A non-extensive view of the Pressure Stimulated Current relaxation during repeated abrupt uniaxial load-unload in rock samples
Laboratory experiments have confirmed that the application of uniaxial stress on rock samples is accompanied by the production of weak electric currents, named Pressure Stimulated Currents (PSCs). In the present work the PSC emissions in marble and amphibolite (from the German Continental Deep drilling) samples are studied in the frame of non-extensive statistical mechanics, after having applied sequential loading-unloading cycles. It was ascertained that by increasing the sequential order of the loading-unloading cycle, the emitted PSC exhibits q-exponential behavior with a non-additive entropy parameter q which decreased in each applied uniaxial load-unload cycle. The behavior of the Tsallis q-parameter leads to the conclusion that fracturing is a subadditive process with hierarchically constrained dynamics. Furthermore, assuming an assembly of relaxed subdomains created due to microfracture, a non-extensive behavior of the observed macroscopically PSC relaxation is discussed in the frame of a superstatistical approach
Is pressure stimulated current relaxation in amphibolite a case of non-extensivity?
The application of uniaxial stress on rocks is accompanied by the production of an electric signal which is described by the term pressure stimulated current (PSC). In this work the high rate step stress (HRSS) technique is applied, and the PSC relaxation in amphibolite samples from KTB drilling, is studied in the frame of non-extensive statistical mechanics. After the application of an abrupt stress step, a PSC spike is recorded up to its maximum value PSCmax, decreasing gradually, right after the stress stabilization in a value σH. In the present work we study PSCs relaxation in uniaxial compressed rocks using a generalized exponential function called
q-exponential, which explicitly introduces hierarchically constrained dynamics and interactions. The interactions are associated with the non-extensive entropy parameter q which exhibits a behavior indicating a dependence with the applied uniaxial stress as we approach fracture. The stress-dependent q-estimation leads to the conclusion that fracturing is a subextensive process with hierarchically constrained dynamics. Furthermore, assuming an assembly of relaxed subdomains created due to microfracture, a non-extensive behavior of the observed macroscopically PSC relaxation is discussed in the frame of a superstatistical approach
Correlation between the electric and acoustic signals emitted during compression of brittle materials
An experimental protocol is described including a series of uni¬axial compression tests of three brittle materials (marble, mortar and glass). The Acoustic Emission (AE) technique and the Pressure Stimulated Currents (PSC) one are used since the recordings of both techniques are strongly related to the formation of cracking in brittle materials. In the present paper, the correlation of these techniques is investigated, which is finally proven to be very satisfactory