81 research outputs found

    Recent trends in publication of basic science and clinical research by United States investigators in anesthesia journals

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>United States anesthesia research production declined sharply from 1980-2005. Whether this trend has continued despite recent calls to improve output is unknown. We conducted an observational internet analysis to quantify American basic science and clinical anesthesia research output in 14 anesthesia journals with impact factors greater than one at three-year intervals during the past decade.</p> <p>Results</p> <p>American investigators published 1,486 (21.7%) of the total of 6,845 research articles identified in anesthesia journals in 2001, 2004, 2007, and 2010. Approximately two-thirds of all US articles were published in <it>Anesthesiology </it>and <it>Anesthesia and Analgesia</it>. There was a significant correlation (r<sup>2 </sup>= 0.316; P = 0.036) between the number of articles published by American authors in each anesthesia journal and the corresponding journal's impact factor in 2010. Significantly (P < 0.05; Pearson's Chi-square) fewer basic science articles were published in 2007 and 2010 compared with 2001. US clinical research output also declined in 2007 (201; 15.7%) compared with 2001 (266; 19.1%) and 2004, but an increase occurred in 2010 (279; 21.8%, P < 0.05 versus 2007).</p> <p>Conclusions</p> <p>The results indicate that US anesthesia research output continued to decrease from 2001 to 2007. An increase in clinical but not basic science research was observed in 2010 compared with 2007, suggesting that a modest recovery in clinical research production may have begun.</p

    Assessment of a continuous blood gas monitoring system in animals during circulatory stress

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The study was aimed to determine the measurement accuracy of The CDI™ blood parameter monitoring system 500 (Terumo Cardiovascular Systems Corporation, Ann Arbor MI) in the real-time continuous measurement of arterial blood gases under different cardiocirculatory stress conditions</p> <p>Methods</p> <p>Inotropic stimulation (Dobutamine 2.5 and 5 μg/kg/min), vasoconstriction (Arginine-vasopressin 4, 8 and 16 IU/h), hemorrhage (-10%, -20%, -35%, and -50% of the theoretical volemia), and volume resuscitation were induced in ten swine (57.4 ± 10.7 Kg).Intermittent blood gas assessments were carried out using a routine gas analyzer at any experimental phase and compared with values obtained at the same time settings during continuous monitoring with CDI™ 500 system. The Bland-Altman analysis was employed.</p> <p>Results</p> <p>Bias and precision for pO<sub>2 </sub>were - 0.06 kPa and 0.22 kPa, respectively (r<sup>2 </sup>= 0.96); pCO<sub>2 </sub>- 0.02 kPa and 0.15 kPa, respectively; pH -0.001 and 0.01 units, respectively ( r<sup>2 </sup>= 0.96). The analysis showed very good agreement for SO<sub>2 </sub>(bias 0.04,precision 0.33, r<sup>2 </sup>= 0.95), Base excess (bias 0.04,precision 0.28, r<sup>2 </sup>= 0.98), HCO<sub>3 </sub>(bias 0.05,precision 0.62, r<sup>2 </sup>= 0.92),hemoglobin (bias 0.02,precision 0.23, r<sup>2 </sup>= 0.96) and K<sup>+ </sup>(bias 0.02, precision 0.27, r<sup>2 </sup>= 0.93). The sensor was reliable throughout the experiment during hemodynamic variations.</p> <p>Conclusions</p> <p>Continuous blood gas analysis with the CDI™ 500 system was reliable and it might represent a new useful tool to accurately and timely monitor gas exchange in critically ill patients. Nonetheless, our findings need to be confirmed by larger studies to prove its reliability in the clinical setting.</p

    Transcutaneous Oxygen Monitoring

    No full text

    Reply

    No full text
    • …
    corecore