671 research outputs found

    Experimental Spinal Fusion With Recombinant Human Bone Morphogenetic Protein-2 Without Decortication of Osseous Elements

    Get PDF
    Study Design. L4-L5 intertransverse process fusions were produced with 58 μg, 230 μg, or 920 μg of recombinant human bone morphogenetic protein-2 in 20 dogs. Eleven had traditional decortication of posterior elements before insertion of the implant. Nine were left undecorticated. All animals were evaluated 3 months after surgery. Objectives. To determine whether decortication is a prerequisite for successful fusion in the presence of osteoinductive proteins such as bone morphogenetic protein-2. Summary of Background Data. Recombinant osteoinductive proteins can induce de novo bone in ectopic soft-tissue sites in the absence of bone marrow elements. Traditional methods for achieving spinal fusion rely on exposure of bone marrow through decortication to facilitate osteogenesis. It is hypothesized that the presence of an implanted osteoinductive protein obviates the need for exposure and release of host inductive factors. Methods. Recombinant human bone morphogenetic protein-2-induced intertransverse process fusions were performed with and without decortication. Fusion sites were evaluated by computed tomography imaging, high-resolution radiography, manual testing, mechanical testing, and histologic analysis. Results. One hundred percent of decorticated spines and 89% of undecorticated spines were clinically fused by 3 months. Ninety-one percent of decorticated spines and 78% of undecorticated specimens exhibited bilateral transverse process osseous bridging. The only spines that failed to achieve solid bilateral arthrodesis were in the lowest dose group. With the higher two doses, there was histologic evidence of osseous continuity between the fusion mass and undecorticated transverse processes. Conclusions. There were no statistical differences in clinical and radiographic fusion rates between decorticated and undecorticated sites. With higher doses of recombinant human bone morphogenetic protein-2, there was little histologic distinction between fusions in decorticated versus undecorticated spines

    Histologic Evaluation of the Efficacy of rhBMP-2 Compared With Autograft Bone in Sheep Spinal Anterior Interbody Fusion

    Get PDF
    Study Design. The sheep anterior lumbar spinal fusion model was used to study the efficacy of recombinant human bone morphogenetic protein-2 (rhBMP-2)–collagen composite in comparison with autograft to enhance spinal interbody fusion. Comparisons were drawn from temporal radiographic and end-point biomechanical and histologic data. Objective. To analyze histologically the ability of rhBMP-2 to achieve complete arthrodesis between vertebral bodies. Summary of Background Data. Studies using rhBMP for enhancement of anterior interbody fusion have used numerous endpoints. However, systematic histologic evaluation of the fusion has not been conducted. Methods. Twelve sheep underwent single-level anterior lumbar interbody fusion performed with a cylindrical fenestrated titanium interbody fusion device (INTER FIX, Medtronic Sofamor Danek, Inc., Memphis, TN). The device was filled either with rhBMP-2–collagen (n = 6) or autogenous iliac crest bone graft (n = 6). Radiologic evaluation was carried out at 2-month intervals, and all sheep were killed 6 months after surgery. Nondestructive biomechanical testing for stiffness to flexion, extension, and lateral bending moments, un-decalcified histology, and qualitative and quantitative histologic evaluation were performed. Results. Radiographs revealed a bony bridge anterior to the cage in five of six rhBMP-2-treated animals, whereas it was present only in one of five in the autogenous bone graft group. Segments treated with rhBMP-2 were 20% stiffer in flexion than autograft-treated segments at 6 months. Six of six in the rhBMP-2 group and two of six in the autograft group showed complete fusion. There was a significantly higher rate of bony continuity observed at the fenestrations of the rhBMP-2 group. Three times more number of cage fenestrations in the rhBMP-2 group demonstrated “all-bone” when compared with the autograft group (P \u3c 0.001). Further, the scar tissue in and around the autograft-treated cages was 16-fold more (P \u3c 0.01) than that seen for rhBMP-2-treated cages. Conclusions. The study demonstrates that rhBMP-2 can lead to earlier radiologic fusion and a more consistent increased stiffness of the segments when compared with autograft in sheep anterior lumbar interbody fusion. Furthermore, a three times higher histologic fusion rate is attainable with significantly reduced fibrous tissue around the implant when rhBMP-2 is used

    Effective Doses of Recombinant Human Bone Morphogenetic Protein-2 in Experimental Spinal Fusion

    Get PDF
    Study Design Nineteen dogs underwent L4-L5 intertransverse process fusions with either 58 μg, 115 μg, 230 μg, 460 μg, or 920 μg of recombinant human bone morphogenetic protein-2 carried by a polylactic acid polymer. A previous study (12 dogs) compared 2300 μg of recombinant human bone morphogenetic protein-2, autogenous iliac bone, and carrier alone in this model. All fusions subsequently were compared. Objectives To characterize the dose-response relationship of recombinant human bone morphogenetic protein-2 in a spinal fusion model. Summary of Background Data Recombinant osteoinductive morphogens, such as recombinant human bone morphogenetic protein-2, are effective in vertebrate diaphyseal defect and spinal fusion models. It is hypothesized that the quality of spinal fusion produced with recombinant human bone morphogenetic protein-2, above a threshold dose, does not change with increasing amounts of inductive protein. Methods After decortication of the posterior elements, the designated implants were placed along the intertransverse process space bilaterally. The fusion sites were evaluated after 3 months by computed tomography imaging, high-resolution radiography, manual testing, mechanical testing, and histologic analysis. Results As in the study using 2300 μg of recombinant human bone morphogenetic protein-2, implantation of 58–920 μg of recombinant human bone morphogenetic protein-2 successfully resulted in intertransverse process fusion in the dog by 3 months. This had not occurred in animals containing autograft or carrier alone. The cross-sectional area of the fusion mass and mechanical stiffness of the L4-L5 intersegment were not dose-dependent. Histologic findings varied but were not related to rhBMP-2 dose. Inflammatory reaction to the composite implant was proportional inversely to the volume of the fusion mass. Conclusions No mechanical, radiographic, or histologic differences in the quality of intertransverse process fusion resulted from a 40-fold variation in dose of recombinant human bone morphogenetic protein-2

    Dark Patterns and the Legal Requirements of Consent Banners: An Interaction Criticism Perspective

    Get PDF
    User engagement with data privacy and security through consent banners has become a ubiquitous part of interacting with internet services. While previous work has addressed consent banners from either interaction design, legal, and ethics-focused perspectives, little research addresses the connections among multiple disciplinary approaches, including tensions and opportunities that transcend disciplinary boundaries. In this paper, we draw together perspectives and commentary from HCI, design, privacy and data protection, and legal research communities, using the language and strategies of "dark patterns" to perform an interaction criticism reading of three different types of consent banners. Our analysis builds upon designer, interface, user, and social context lenses to raise tensions and synergies that arise together in complex, contingent, and conflicting ways in the act of designing consent banners. We conclude with opportunities for transdisciplinary dialogue across legal, ethical, computer science, and interactive systems scholarship to translate matters of ethical concern into public policy.Comment: 18 page

    MAGNETIC FLUX CONSERVATION IN THE HELIOSHEATH INCLUDING SOLAR CYCLE VARIATIONS OF MAGNETIC FIELD INTENSITY

    Get PDF
    In the heliosheath (HS), Voyager 2 has observed a flow with constant radial velocity and magnetic flux conservation. Voyager 1, however, has observed a decrease in the flow's radial velocity and an order of magnitude decrease in magnetic flux. We investigate the role of the 11 yr solar cycle variation of the magnetic field strength on the magnetic flux within the HS using a global 3D magnetohydrodynamic model of the heliosphere. We use time and latitude-dependent solar wind velocity and density inferred from Solar and Heliospheric Observatory/SWAN and interplanetary scintillations data and implemented solar cycle variations of the magnetic field derived from 27 day averages of the field magnitude average of the magnetic field at 1 AU from the OMNI database. With the inclusion of the solar cycle time-dependent magnetic field intensity, the model matches the observed intensity of the magnetic field in the HS along both Voyager 1 and 2. This is a significant improvement from the same model without magnetic field solar cycle variations, which was over a factor of two larger. The model accurately predicts the radial velocity observed by Voyager 2; however, the model predicts a flow speed ~100 km s[superscript −1] larger than that derived from LECP measurements at Voyager 1. In the model, magnetic flux is conserved along both Voyager trajectories, contrary to observations. This implies that the solar cycle variations in solar wind magnetic field observed at 1 AU does not cause the order of magnitude decrease in magnetic flux observed in the Voyager 1 data.United States. National Aeronautics and Space Administration (Earth and Space Science Fellowship Program Grant NNX14AO14H

    Active immunisation of mice with GnRH lipopeptide vaccine candidates: importance of T helper or multi-dimer GnRH epitope

    Get PDF
    Active immunisation against gonadotropin releasing hormone (GnRH) is a potential alternative to surgical castration. This study focused on the development of a GnRH subunit lipopeptide vaccine. A library of vaccine candidates that contained one or more (up to eight) copies of monomeric or dimeric GnRH peptide antigen, an adjuvanting lipidic moiety based on lipoamino acids, and an additional T helper epitope, was synthesised by solid phase peptide synthesis. The candidates were evaluated in vivo in order to determine the minimal components of this vaccine necessary to induce a systemic immune response. BALB/c mice were immunised with GnRH lipopeptide conjugates, co-administered with or without Complete Freund's Adjuvant, followed by two additional immunisations. Significant GnRH-specific IgG titres were detected in sera obtained from mice immunised with four of the seven lipopeptides tested, with an increase in titres observed after successive immunisations. This study highlights the importance of for epitope optimisation and delivery system design when producing anti-hapten antibodies in vivo. The results of this study also contribute to the development of future clinical and veterinary immunocontraceptives

    Multiantigenic peptide-polymer conjugates as therapeutic vaccines against cervical cancer

    Get PDF
    Immunotherapy is one of the most promising strategies for the treatment of cancer. Human papillomavirus (HPV) is responsible for virtually all cases of cervical cancer. The main purpose of a therapeutic HPV vaccine is to stimulate CD8(+) cytotoxic T lymphocytes (CTLs) that can eradicate HPV infected cells. HPV oncoproteins E6 and E7 are continuously expressed and are essential for maintaining the growth of HPV-associated tumor cells. We designed polymer-based multi-antigenic formulations/constructs that were comprised of the E6 and E7 peptide epitopes. We developed an N-terminus-based epitope conjugation to conjugate two unprotected peptides to poly tert-butyl acrylate. This method allowed for the incorporation of the two antigens into a polymeric dendrimer in a strictly equimolar ratio. The most effective formulations eliminated tumors in up to 50% of treated mice. Tumor recurrence was not observed up to 3 months post initial challenge. (C) 2016 Elsevier Ltd. All rights reserved

    Lipid core peptide/poly(lactic-co-glycolic acid) as a highly potent intranasal vaccine delivery system against Group A streptococcus

    Get PDF
    Rheumatic heart disease represents a leading cause of mortality caused by Group A Streptococcus (GAS) infections transmitted through the respiratory route. Although GAS infections can be treated with antibiotics these are often inadequate. An efficacious GAS vaccine holds more promise, with intranasal vaccination especially attractive, as it mimics the natural route of infections and should be able to induce mucosal IgA and systemic IgG immunity. Nanoparticles were prepared by either encapsulating or coating lipopeptide-based vaccine candidate (LCP-1) on the surface of poly(lactic-co-glycolic acid) (PLGA). In vitro study showed that encapsulation of LCP-1 vaccine into nanoparticles improved uptake and maturations of antigen-presenting cells. The immunogenicity of lipopeptide incorporated PLGA-based nanoparticles was compared with peptides co-administered with mucosal adjuvant cholera toxin B in mice upon intranasal administration. Higher levels of J14-specific salivary mucosal IgA and systemic antibody IgG titres were observed for groups immunized with encapsulated LCP-1 compared to LCP-1 coated nanoparticles or free LCP-1. Systemic antibodies obtained from LCP-1 encapsulated PLGA NPs inhibited the growth of bacteria in six different GAS strains. Our results show that PLGA-based lipopeptide delivery is a promising approach for rational design of a simple, effective and patient friendly intranasal GAS vaccine resulting in mucosal IgA response
    corecore