14 research outputs found

    A modified Park's stitch to correct aortic insufficiency for bioprosthetic valve at time of left ventricular assist device implant: a case report

    Get PDF
    Background: Aortic valve insufficiency (AI) at the time of left ventricular assist device (LVAD) insertion needs to be corrected, however there is little known about how to manage bioprosthetic valvular AI. Case presentation: A 55-year-old female with dilated cardiomyopathy who previously had a bioprosthetic aortic valve replacement needed a LVAD as a bridge to transplant. Her left ventricular ejection fraction was 10% and had mild to moderate transvalvular AI. She underwent a HeartWare HVAD insertion along with aortic valvular coaptation stitch repair (Park's stitch) to the bioprosthetic valve. Conclusion: Her AI improved to trivial with minimal ejection through the bioprosthetic valve. She was transplanted 6 months following the surgery. A Park's stitch to the bioprosthetic aortic valve with more than mild AI might be a good option for bridge to transplant patient.This item from the UA Faculty Publications collection is made available by the University of Arizona with support from the University of Arizona Libraries. If you have questions, please contact us at [email protected]

    Right ventricular functional analysis utilizing first pass radionuclide angiography for pre-operative ventricular assist device planning: a multi-modality comparison

    No full text
    Abstract Background Advanced heart failure treated with a left ventricular assist device is associated with a higher risk of right heart failure. Many advanced heart failures patients are treated with an ICD, a relative contraindication to MRI, prior to assist device placement. Given this limitation, left and right ventricular function for patients with an ICD is calculated using radionuclide angiography utilizing planar multigated acquisition (MUGA) and first pass radionuclide angiography (FPRNA), respectively. Given the availability of MRI protocols that can accommodate patients with ICDs, we have correlated the findings of ventricular functional analysis using radionuclide angiography to cardiac MRI, the reference standard for ventricle function calculation, to directly correlate calculated ejection fractions between these modalities, and to also assess agreement between available echocardiographic and hemodynamic parameters of right ventricular function. Methods A retrospective review from January 2012 through May 2014 was performed to identify advanced heart failure patients who underwent both cardiac MRI and radionuclide angiography for ventricular functional analysis. Nine heart failure patients (8 men, 1 woman; mean age of 57.0 years) were identified. The average time between the cardiac MRI and radionuclide angiography exams was 38.9 days (range: 1 - 119 days). All patients undergoing cardiac MRI were scanned using an institutionally approved protocol for ICD with no device-related complications identified. A retrospective chart review of each patient for cardiomyopathy diagnosis, clinical follow-up, and echocardiogram and right heart catheterization performed during evaluation was also performed. Results The 9 patients demonstrated a mean left ventricular ejection fraction (LVEF) using cardiac MRI of 20.7% (12 – 40%). Mean LVEF using MUGA was 22.6% (12 – 49%). The mean right ventricular ejection fraction (RVEF) utilizing cardiac MRI was 28.3% (16 – 43%), and the mean RVEF calculated by FPRNA was 32.6% (9 – 56%). The mean discrepancy for LVEF between cardiac MRI and MUGA was 4.1% (0 – 9%), and correlation of calculated LVEF using cardiac MRI and MUGA demonstrated an R of 0.9. The mean discrepancy for RVEF between cardiac MRI and FPRNA was 12.0% (range: 2 – 24%) with a moderate correlation (R = 0.5). The increased discrepancies for RV analysis were statistically significant using an unpaired t-test (t = 3.19, p = 0.0061). Echocardiogram parameters of RV function, including TAPSE and FAC, were for available for all 9 patients and agreement with cardiac MRI demonstrated a kappa statistic for TAPSE of 0.39 (95% CI of 0.06 – 0.72) and for FAC of 0.64 (95% of 0.21 – 1.00). Conclusion Heart failure patients are increasingly requiring left ventricular assist device placement; however, definitive evaluation of biventricular function is required due to the increased mortality rate associated with right heart failure after assist device placement. Our results suggest that FPRNA only has a moderate correlation with reference standard RVEFs calculated using cardiac MRI, which was similar to calculated agreements between cardiac MRI and echocardiographic parameters of right ventricular function. Given the need for identification of patients at risk for right heart failure, further studies are warranted to determine a more accurate estimate of RVEF for heart failure patients during pre-operative ventricular assist device planning

    Suspected Heparin-Induced Thrombocytopenia in Patients Receiving Extracorporeal Membrane Oxygenation

    No full text
    Heparin-induced thrombocytopenia (HIT) is an immune reaction usually secondary to unfractionated heparin. Anticoagulation management is critical in patients while on extracorporeal membrane oxygenation (ECMO) to prevent thromboembolism and for the optimal functioning of the circuit. We identified five patients with respiratory failure at our hospital managed with ECMO in the last 2 years that were treated for HIT. A brief clinical course and their management are discussed. We also briefly review the literature for best evidence for management of such patients

    Predictors of Oxygenator Exchange in Patients Receiving Extracorporeal Membrane Oxygenation

    No full text
    Thrombosis within the membrane oxygenator (MO) during extracorporeal membrane oxygenation (ECMO) can lead to sudden oxygenator dysfunction with deleterious effects to the patient. The purpose of this study was to identify predictors of circuit exchange during ECMO. This is a single-center, retrospective study of all patients who received ECMO at our institution from January 2010 to December 2015. Changes in potential markers were compared on Day 3 vs. Day 0 before MO exchange. Of the 150 patients who received ECMO, there were 58 MO exchanges in 35 patients. Mean ECMO duration was 21.1 (±12.7) days. D-dimer (DD) (μg/mL) (mean difference −2.6; 95% confidence interval [CI]: −4.2 to −1.1; p = .001) increased significantly in the 3 days leading up to MO exchange, whereas fibrinogen (mg/dL) (mean difference 90.7; 95% CI: 41.8–139.6; p = .001), platelet (PLT) count (1,000/μL) (mean difference 23.3; 95% CI: 10.2–36.4; p = .001), and heparin dose (units/h) (mean difference 261.7; 95% CI: 46.3–477.1; p = .02) decreased. Increasing DD or decreasing fibrinogen, PLT count, or heparin dose may indicate an impending need for MO exchange in patients receiving ECMO. Early identification of these changes may help prevent sudden MO dysfunction

    A Case Report of Severe Factor XI Deficiency during Cardiac Surgery: Less Can Be More

    No full text
    Severe congenital Factor XI (FXI) deficiency (<20% normal activity) can be associated with significant bleeding disorders, and there has been great concern for severe bleeding following cardiac surgery requiring cardiopulmonary bypass (CPB) in this patient population. Over the past four decades remarkably different approaches to this problem have been taken, including the administration of blood volumes of fresh frozen plasma, administration of activated recombinant Factor VII, and diminutive administration of heparin. We describe a case wherein the patient was assessed in the perioperative period with a point-of-care, viscoelastic hemostasis device (ROTEM), with changes in the intrinsic/Factor XII-dependent coagulation pathway determined before, during, and after CPB. Fresh frozen plasma was administered in small amounts (5–7.5 mL/kg) just before surgery began and just before cessation of CPB. Administering fresh frozen plasma to the patient to nearly normalize in vitro ROTEM hemostasis values at times when hemostasis was needed resulted in no important bleeding occurring or need of further transfusion of other blood products. In conclusion, by using small amounts of fresh frozen plasma guided by ROTEM, an evidenced-based, precision medicine approach resulted in optimized patient care and outcome

    A dual therapy of off-pump temporary left ventricular extracorporeal device and amniotic stem cell for cardiogenic shock

    No full text
    Background: Temporary mechanical circulatory support device without sternotomy has been highly advocated for severe cardiogenic shock patient but little is known when coupled with amniotic stem cell therapy. Case presentation: This case reports the first dual therapy of temporary left ventricular extracorporeal device CentriMag with distal banding technique and human amniotic stem cell injection for treating a severe refractory cardiogenic shock of an 68-year-old female patient. A minimally-invasive off-pump LVAD was established by draining from the left ventricle and returning to the right axillary artery with distal arterial banding to prevent right upper extremity hyperperfusion. Amniotic stem cells were injected intramyocardially at the left ventricular apex, lateral wall, inferior wall, and right subclavian vein. Conclusion: The concomitant use of the temporary minimally-invasive off-pump CentriMag placement and stem cell therapy not only provided an alternative to cardiopulmonary bypass and full-median sternotomy procedures but may have also synergistically enhanced myocardial reperfusion and regeneration.This item from the UA Faculty Publications collection is made available by the University of Arizona with support from the University of Arizona Libraries. If you have questions, please contact us at [email protected]

    Minimally invasive approach for percutaneous CentriMag right ventricular assist device support using a single PROTEKDuo Cannula

    No full text
    Background: Right ventricular failure is a serious complication after left ventricular assist device placement. Case Presentation: A 70-year-old male in decompensated heart failure with right ventricular failure after the placement of a left ventricular assist device. A single dual-lumen PROTEKDuo cannula was inserted percutaneously via the internal jugular vein to draw blood from the right atrium and return into the pulmonary artery using the CentriMag system, by passing the failing ventricle. The patient was successfully weaned from right ventricular assist device. Conclusions: In comparison to two-cannula conventional procedures, this right ventrivular assist device system improves patient rehabilitation and minimizes blood loss and risk of infection, while shortening procedure time and improving clinical outcomes in right ventricular failure.This item from the UA Faculty Publications collection is made available by the University of Arizona with support from the University of Arizona Libraries. If you have questions, please contact us at [email protected]