31 research outputs found

    Precision planar drift chambers and cradle for the TWIST muon decay spectrometer

    Full text link
    To measure the muon decay parameters with high accuracy, we require an array of precision drift detector layers whose relative position is known with very high accuracy. This article describes the design, construction and performance of these detectors in the TWIST (TRIUMF Weak Interaction Symmetry Test) spectrometer.Comment: 44 pages, 16 Postscript figures, LaTeX2e, uses Elsevier class elsart.cls, package graphicx, submitted to Nuclear Instruments & Methods in Physics Researc

    Measurement of the Muon Decay Parameter delta

    Full text link
    The muon decay parameter delta has been measured by the TWIST collaboration. We find delta = 0.74964 +- 0.00066(stat.) +- 0.00112(syst.), consistent with the Standard Model value of 3/4. This result implies that the product Pmuxi of the muon polarization in pion decay, Pmu, and the muon decay parameter xi falls within the 90% confidence interval 0.9960 < Pmuxi < xi < 1.0040. It also has implications for left-right-symmetric and other extensions of the Standard Model.Comment: Extended to 5 pages. Referee's comments answere

    Measurement of P_{mu}xi in Polarized Muon Decay

    Full text link
    The quantity P_{mu}^{pi}xi, where xi is one of the muon decay parameters and PμπP_{\mu}^{\pi} is the degree of muon polarization in pion decay, has been measured. The value P_{mu}^{pi}xi = 1.0003 +- 0.0006 stat. +- 0.0038 syst. was obtained. This result agrees with previous measurements but is over a factor of two more precise. It also agrees with the Standard Model prediction for P_{mu}^{pi}xi and thus leads to restrictions on left-right symmetric models.Comment: 11 pages, 7 figures, Phys. Rev. D 74, 072007 (2006) Final versio

    Measurement of the Michel Parameter ρ\rho in Muon Decay

    Full text link
    The TWIST Collaboration has measured the Michel parameter ρ\rho in normal muon decay, μ+e+νeνˉμ\mu^+ \to e^+ \nu_e \bar{\nu}_{\mu}. In the Standard Model, ρ\rho = 3/4. Deviations from this value require mixing of left- and right-handed muon and electron couplings in the muon-decay Lagrangian. We find ρ\rho = 0.75080 ±\pm 0.00044(stat.) ±\pm 0.00093(syst.) ±\pm 0.00023, where the last uncertainty represents the dependence of ρ\rho on the Michel parameter η\eta. This result sets new limits on the WLWRW_L-W_R mixing angle in left-right symmetric models.Comment: 4 pages, 3 figures, submitted to PR
    corecore