68 research outputs found
Absorption characteristics of compounds with different molecular weights after application to the unilateral kidney surface in rats
The aim of the present study is to clarify the absorption mechanism of a drug from the kidney surface membrane in rats. We studied the absorption characteristics of phenolsulfonphthalein (PSP) and other compounds with different molecular weights after their application to the rat kidney surface in vivo, employing a cylindrical diffusion cell (i.d. 6 mm, area 0.28 cm2). The time course of free PSP amounts remaining in the diffusion cell obeyed first-order kinetics at a dose of 1 mg, and its rate constant ka was calculated to be 0.0137 min?1. Absorption ratios of PSP in 4 h were calculated (from the amount recovered from the diffusion cell) to be 91.4, 96.4 and 97.7% at doses of 0.5, 1 and 1.5 mg, respectively. The area under the curve for the plasma concentration profile of free PSP was proportional to the application dose. It is thus suggested that the absorption process of PSP from the rat kidney surface does not approach saturation at a dose of 1.5 mg. Also, no significant difference was seen in the ka values within the dose range of 0.5?1.5 mg, which were estimated by curve-fitting the plasma concentration profiles of free PSP in a two-compartment model with first-order absorption. Furthermore, we examined the importance of molecular weight on the absorption from the kidney surface using fluorescein isothiocyanate-dextrans (FDs) with molecular weights of 4400 (FD-4), 11,000 (FD-10), 40,500 (FD-40) or 69,000 (FD-70), including the organic anions bromphenol blue and bromosulfonphthalein. The absorption ratios of FDs from the rat kidney surface in 6 h decreased with an increase in the molecular weight (76.1% for FD-4, 54.4% for FD-10, 11.5% for FD-40 and 3.9% for FD-70). A linear relationship was observed between ka and the reciprocal value of z the square root of the molecular weight of these compounds. The limit of absorption from the rat kidney surface was extrapolated to be at a molecular weight of approximately 130,000
Prediction of acid mine drainage formation and zinc migration in the tailings dam of a closed mine, and possible countermeasures
Acid mine drainage (AMD), the very acidic and highly contaminated leachate generated in closed/abandoned mines, is commonly managed by neutralization to raise the pH and precipitate most of the heavy metals. Although effective, this approach does not generate any product of economic value, so it is very costly and unsustainable in the long-term. Unfortunately, there are currently no effective alternatives to neutralization, and one way to improve the sustainability of this process is to reduce the volume of AMD generated and/or the concentration of heavy metals. The tailings dam investigated in this study is located in northern Hokkaido, Japan. Detailed characterization of borehole core samples showed that even after almost 40 years of exposure to the environment, the tailings still contain pyrite (FeS2) and substantial amounts of copper (Cu) and zinc (Zn). Reactive-transport modeling using Visual MODFLOW predicted that AMD quality would likely continue to deteriorate with time and that treatment should be continued for at least 1,000 years. The model also predicted that a barrier with low permeability installed downstream of the tailings dam or ground sealing techniques for recharge reduction could lower the volume of AMD and concentration of Zn from the site
Preclinical Evaluation of Biodistribution and Toxicity of [211At]PSMA-5 in Mice and Primates for the Targeted Alpha Therapy against Prostate Cancer
Watabe T., Kaneda-Nakashima K., Kadonaga Y., et al. Preclinical Evaluation of Biodistribution and Toxicity of [211At]PSMA-5 in Mice and Primates for the Targeted Alpha Therapy against Prostate Cancer. International Journal of Molecular Sciences 25, 5667 (2024); https://doi.org/10.3390/ijms25115667.Astatine (211At) is a cyclotron-produced alpha emitter with a physical half-life of 7.2 h. In our previous study, the 211At-labeled prostate-specific membrane antigen (PSMA) compound ([211At]PSMA-5) exhibited excellent tumor growth suppression in a xenograft model. We conducted preclinical biodistribution and toxicity studies for the first-in-human clinical trial. [211At]PSMA-5 was administered to both normal male ICR mice (n = 85) and cynomolgus monkeys (n = 2). The mice were divided into four groups for the toxicity study: 5 MBq/kg, 12 MBq/kg, 35 MBq/kg, and vehicle control, with follow-ups at 1 day (n = 10 per group) and 14 days (n = 5 per group). Monkeys were observed 24 h post-administration of [211At]PSMA-5 (9 MBq/kg). Blood tests and histopathological examinations were performed at the end of the observation period. Blood tests in mice indicated no significant myelosuppression or renal dysfunction. However, the monkeys displayed mild leukopenia 24 h post-administration. Despite the high accumulation in the kidneys and thyroid, histological analysis revealed no abnormalities. On day 1, dose-dependent single-cell necrosis/apoptosis was observed in the salivary glands of mice and intestinal tracts of both mice and monkeys. Additionally, tingible body macrophages in the spleen and lymph nodes indicated phagocytosis of apoptotic B lymphocytes. Cortical lymphopenia (2/10) in the thymus and a decrease in the bone marrow cells (9/10) were observed in the 35 MBq/kg group in mice. These changes were transient, with no irreversible toxicity observed in mice 14 days post-administration. This study identified no severe toxicities associated with [211At]PSMA-5, highlighting its potential as a next-generation targeted alpha therapy for prostate cancer. The sustainable production of 211At using a cyclotron supports its applicability for clinical use
Sitagliptin and Carotid Atherosclerosis in Type 2 Diabetes
Background
Experimental studies have suggested that dipeptidyl peptidase-4 (DPP-4) inhibitors provide cardiovascular protective effects. We performed a randomized study to evaluate the effects of sitagliptin added on to the conventional therapy compared with conventional therapy alone (diet, exercise, and/or drugs, except for incretin-related agents) on the intima-media thickness (IMT) of the carotid artery, a surrogate marker for the evaluation of atherosclerotic cardiovascular disease, in people with type 2 diabetes mellitus (T2DM).
Methods and Findings
We used a multicenter PROBE (prospective, randomized, open label, blinded endpoint) design. Individuals aged ≥30 y with T2DM (6.2% ≤ HbA1c < 9.4%) were randomly allocated to receive either sitagliptin (25 to 100 mg/d) or conventional therapy. Carotid ultrasound was performed at participating medical centers, and all parameters were measured in a core laboratory. Of the 463 enrolled participants with T2DM, 442 were included in the primary analysis (sitagliptin group, 222; conventional therapy group, 220). Estimated mean (± standard error) common carotid artery IMT at 24 mo of follow-up in the sitagliptin and conventional therapy groups was 0.827 ± 0.007 mm and 0.837 ± 0.007 mm, respectively, with a mean difference of −0.009 mm (97.2% CI −0.028 to 0.011, p = 0.309). HbA1c level at 24 mo was significantly lower with sitagliptin than with conventional therapy (6.56% ± 0.05% versus 6.72%± 0.05%, p = 0.008; group mean difference −0.159, 95% CI −0.278 to −0.041). Episodes of serious hypoglycemia were recorded only in the conventional therapy group, and the rate of other adverse events was not different between the two groups. As it was not a placebo-controlled trial and carotid IMT was measured as a surrogate marker of atherosclerosis, there were some limitations of interpretation.
Conclusions
In the PROLOGUE study, there was no evidence that treatment with sitagliptin had an additional effect on the progression of carotid IMT in participants with T2DM beyond that
achieved with conventional treatment
Ultra-High-Resolution Computed Tomography of the Lung: Image Quality of a Prototype Scanner
Purpose: The image noise and image quality of a prototype ultra-high-resolution computed tomography (U-HRCT) scanner was evaluated and compared with those of conventional high-resolution CT (C-HRCT) scanners. Materials and Methods: This study was approved by the institutional review board. A U-HRCT scanner prototype with 0.25 mm × 4 rows and operating at 120 mAs was used. The C-HRCT images were obtained using a 0.5 mm × 16 or 0.5 mm × 64 detector-row CT scanner operating at 150 mAs. Images from both scanners were reconstructed at 0.1-mm intervals; the slice thickness was 0.25 mm for the U-HRCT scanner and 0.5 mm for the C-HRCT scanners. For both scanners, the display field of view was 80 mm. The image noise of each scanner was evaluated using a phantom. U-HRCT and C-HRCT images of 53 images selected from 37 lung nodules were then observed and graded using a 5-point score by 10 board-certified thoracic radiologists. The images were presented to the observers randomly and in a blinded manner. Results: The image noise for U-HRCT (100.87 ± 0.51 Hounsfield units [HU]) was greater than that for C-HRCT (40.41 ± 0.52 HU; P <.0001). The image quality of U-HRCT was graded as superior to that of C-HRCT (P <.0001) for all of the following parameters that were examined: margins of subsolid and solid nodules, edges of solid components and pulmonary ves sels in subsolid nodules, air bronchograms, pleural indentations, margins of pulmonary vessels, edges of bronchi, and interlobar fissures. Conclusion: Despite a larger image noise, the prototype U-HRCT scanner had a significantly better image quality than the C-HRCT scanners
- …