18 research outputs found

    Proteomic mapping of atrial and ventricular heart tissue in patients with aortic valve stenosis

    Get PDF
    Aortic valve stenosis (AVS) is one of the most common valve diseases in the world. However, detailed biological understanding of the myocardial changes in AVS hearts on the proteome level is still lacking. Proteomic studies using high-resolution mass spectrometry of formalin-fixed and paraffin-embedded (FFPE) human myocardial tissue of AVS-patients are very rare due to methodical issues. To overcome these issues this study used high resolution mass spectrometry in combination with a stem cell- derived cardiac specific protein quantification-standard to profile the proteomes of 17 atrial and 29 left ventricular myocardial FFPE human myocardial tissue samples from AVS-patients. In our proteomic analysis we quantified a median of 1980 (range 1495–2281) proteins in every single sample and identified significant upregulation of 239 proteins in atrial and 54 proteins in ventricular myocardium. We compared the proteins with published data. Well studied proteins reflect disease-related changes in AVS, such as cardiac hypertrophy, development of fibrosis, impairment of mitochondria and downregulated blood supply. In summary, we provide both a workflow for quantitative proteomics of human FFPE heart tissue and a comprehensive proteomic resource for AVS induced changes in the human myocardium

    COVID-19 infection in patients with history of pediatric heart transplant in Germany, Austria, and Switzerland.

    Get PDF
    COVID-19 is a heterogenous infection-asymptomatic to fatal. While the course of pediatric COVID-19 infections is usually mild or even asymptomatic, individuals after adult heart transplantation are at high risk of a severe infection. We conducted a retrospective, multicenter survey of 16 pediatric heart transplant centers in Germany, Austria and Switzerland to evaluate the risk of a severe COVID-19 infection after pediatric heart transplantation between 02/2020 and 06/2021. Twenty-six subjects (11 male) with a median age of 9.77 years at time of transplantation and a median of 4.65 years after transplantation suffered from COVID-19 infection. The median age at time of COVID-10 infection was 17.20 years. Fourteen subjects had an asymptomatic COVID-19 infection. The most frequent symptoms were myalgia/fatigue (n = 6), cough (n = 5), rhinitis (n = 5), and loss of taste (n = 5). Only one subject showed dyspnea. Eleven individuals needed therapy in an outpatient setting, four subjects were hospitalized. One person needed oxygen supply, none of the subjects needed non-invasive or invasive mechanical ventilation. No specific signs for graft dysfunction were found by non-invasive testing. In pediatric heart transplant subjects, COVID-19 infection was mostly asymptomatic or mild. There were no SARS-CoV-2 associated myocardial dysfunction in heart transplant individuals

    Early results of coronary artery bypass grafting with coronary endarterectomy for severe coronary artery disease

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Despite the existence of controversial debates on the efficiency of coronary endarterectomy (CE), it is still used as an adjunct to coronary artery bypass grafting (CABG). This is particularly true in patients with endstage coronary artery disease. Given the improvements in cardiac surgery and postoperative care, as well as the rising number of elderly patient with numerous co-morbidities, re-evaluating the pros and cons of this technique is needed.</p> <p>Methods</p> <p>Patient demographic information, operative details and outcome data of 104 patients with diffuse calcified coronary artery disease were retrospectively analyzed with respect to functional capacity (NYHA), angina pectoris (CCS) and mortality. Actuarial survival was reported using a Kaplan-Meyer analysis.</p> <p>Results</p> <p>Between August 2001 and March 2005, 104 patients underwent coronary artery bypass grafting (CABG) with adjunctive coronary endarterectomy (CE) in the Department of Thoracic-, Cardiac- and Vascular Surgery, University of Goettingen. Four patients were lost during follow-up. Data were gained from 88 male and 12 female patients; mean age was 65.5 ± 9 years. A total of 396 vessels were bypassed (4 ± 0.9 vessels per patient). In 98% left internal thoracic artery (LITA) was used as arterial bypass graft and a total of 114 vessels were endarterectomized. CE was performed on right coronary artery (RCA) (n = 55), on left anterior descending artery (LAD) (n = 52) and circumflex artery (RCX) (n = 7). Ninety-five patients suffered from 3-vessel-disease, 3 from 2-vessel- and 2 from 1-vessel-disease. Closed technique was used in 18%, open technique in 79% and in 3% a combination of both. The most frequent endarterectomized localization was right coronary artery (RCA = 55%). Despite the severity of endstage atherosclerosis, hospital mortality was only 5% (n = 5). During follow-up (24.5 ± 13.4 months), which is 96% complete (4 patients were lost caused by unknown address) 8 patients died (cardiac failure: 3; stroke: 1; cancer: 1; unknown reasons: 3). NYHA-classification significantly improved after CABG with CE from 2.2 ± 0.9 preoperative to 1.7 ± 0.9 postoperative. CCS also changed from 2.4 ± 1.0 to 1.5 ± 0.8</p> <p>Conclusion</p> <p>Early results of coronary endarterectomy are acceptable with respect to mortality, NYHA & CCS. This technique offers a valuable surgical option for patients with endstage coronary artery disease in whom complete revascularization otherwise can not be obtained. Careful patient selection will be necessary to assure the long-term benefit of this procedure.</p

    Region-Specific Microstructure in the Neonatal Ventricles of a Porcine Model

    Get PDF
    © 2018, Biomedical Engineering Society. The neonate transitions from placenta-derived oxygen, to supply from the pulmonary system, moments after birth. This requires a series of structural developments to divert more blood through the right heart and onto the lungs, with the tissue quickly remodelling to the changing ventricular workload. In some cases, however, the heart structure does not fully develop causing poor circulation and inefficient oxygenation, which is associated with an increase in mortality and morbidity. This study focuses on developing an enhanced knowledge of the 1-day old heart, quantifying the region-specific microstructural parameters of the tissue. This will enable more accurate mathematical and computational simulations of the young heart. Hearts were dissected from 12, 1-day-old deceased Yorkshire piglets (mass: 2.1–2.4kg, length: 0.38–0.51m), acquired from a breeding farm. Evans blue dye was used to label the heart equator and to demarcate the left and right ventricle free walls. Two hearts were used for three-dimensional diffusion-tensor magnetic resonance imaging, to quantify the fractional anisotropy (FA). The remaining hearts were used for two-photon excited fluorescence and second-harmonic generation microscopy, to quantify the cardiomyocyte and collagen fibril structures within the anterior and posterior aspects of the right and left ventricles. FA varied significantly across both ventricles, with the greatest in the equatorial region, followed by the base and apex. The FA in each right ventricular region was statistically greater than that in the left. Cardiomyocyte and collagen fibre rotation was greatest in the anterior wall of both ventricles, with less dispersion when compared to the posterior walls. In defining these key parameters, this study provides a valuable insight into the 1-day-old heart that will provide a valuable platform for further investigation the normal and abnormal heart using mathematical and computational models

    Modifications of Surgical Suction Tip Geometry for Flow Optimisation: Influence on Suction-Induced Noise Pollution

    No full text
    Introduction. Suction devices for clearing the surgical field are among the most commonly used tools of every surgeon because a better view of the surgical field is essential. Forced suction may produce disturbingly loud noise, which acts as a nonnegligible stressor. Especially, in emergency situations with heavy bleeding, this loud noise has been described as an impeding factor in the medical decision-making process. In addition, there are reports of inner ear damage in patients due to suction noises during operations in the head area. These problems have not been solved yet. The purpose of this study was to analyse flow-dependent suction noise effects of different surgical suction tips. Furthermore, we developed design improvements to these devices. Methods. We compared five different geometries of suction tips using an in vitro standardised setup. Two commercially available standard suction tips were compared to three adapted new devices regarding their flow-dependent (10–2000 mL/min) noise emission (dB, weighting filter (A), distance 10 cm) and acoustic quality of resulting noises (Hamilton fast Fourier analysis) during active suction at the liquid-air boundary. Noise maps at different flow rates were created for all five suction devices, and the proportion of extracted air was measured. The geometries of the three custom-made suction tips (new models 1, 2, and 3) were designed considering the insights after determining the key characteristics of the two standard suction models. Results. The geometry of a suction device tip has significant impact on its noise emission. For the standard models, the frequency spectrum at higher flow rates significantly changes to high-frequency noise patterns (>3 kHz). A number of small side holes designed to prevent tissue adhesion lead to increased levels of high-frequency noise. Due to modifications of the tip geometry in our new models, we are able to achieve a highly significant reduction of noise level at low flow rates (new model 2 vs. standard models p<0.001) and also the acoustic quality improved. Additionally, we attain a highly significant reduction of secondary air intake (new model 2 vs. the other models p<0.001). Conclusion. Improving flow-relevant features of the geometry of suction heads is a suitable way to reduce noise emissions. Optimized suction tips are significantly quieter. This may help us to reduce noise-induced hearing damage in patients as well as stress of medical staff during surgery and should lead to quieter operation theatres overall. Furthermore, the turbulence reduction and reduced secondary air intake during the suction process are expected to result in protective effects on the collected blood and thus could improve the quality of autologous blood retransfusions. We are on the way to evaluate potential benefits

    Hemodynamic Changes in a Model of Chronic Heart Failure Induced by Multiple Sequential Coronary Microembolization in Sheep

    No full text
    Although a large variety of animal models for acute ischemia and acute heart failure exist, valuable models for studies on the effect of ventricular assist devices in chronic heart failure are scarce. We established a stable and reproducible animal model of chronic heart failure in sheep and aimed to investigate the hemodynamic changes of this animal model of chronic heart failure in sheep. In five sheep (n = 5, 77 +/- 2 kg), chronic heart failure was induced under flouroscopic guidance by multiple sequential microembolization through bolus injection of polysterol microspheres (90 mu m, n = 25.000) into the left main coronary artery. Coronary microembolization (CME) was repeated up to three times in 2 to 3-week intervals until animals started to develop stable signs of heart failure. During each operation, hemodynamic monitoring was performed through implantation of central venous catheter (central venous pressure [CVP]), arterial pressure line (mean arterial pressure [MAP]), implantation of a right heart catheter {Swan-Ganz catheter (mean pulmonary arterial pressure [PAPmean])}, pulmonary capillary wedge pressure (PCWP), and cardiac output [CO]) as well as pre- and postoperative clinical investigations. All animals were followed for 3 months after first microembolization and then sacrificed for histological examination. All animals developed clinical signs of heart failure as indicated by increased heart rate (HR) at rest (68 +/- 4 bpm [base] to 93 +/- 5 bpm [3 mo] [P < 0.05]), increased respiratory rate (RR) at rest (28 +/- 5 [base] to 38 +/- 7 [3 mo] [P < 0.05]), and increased body weight 77 +/- 2 kg to 81 +/- 2 kg (P < 0.05) due to pleural effusion, peripheral edema, and ascites. Hemodynamic signs of heart failure were revealed as indicated by increase of HR, RR, CVP, PAP, and PCWP as well as a decrease of CO, stroke volume, and MAP 3 months after the first CME. Multiple sequential intracoronary microembolization can effectively induce myocardial dysfunction with clinical and hemodynamic signs of chronic ischemic cardiomyopathy. The present model may be suitable in experimental work on heart failure and left ventricular assist devices, for example, for studying the impact of mechanical unloading, mechanisms of recovery, and reverse remodeling
    corecore