5,667 research outputs found
Novel Technique for Ultra-sensitive Determination of Trace Elements in Organic Scintillators
A technique based on neutron activation has been developed for an extremely
high sensitivity analysis of trace elements in organic materials. Organic
materials are sealed in plastic or high purity quartz and irradiated at the
HFIR and MITR. The most volatile materials such as liquid scintillator (LS) are
first preconcentrated by clean vacuum evaporation. Activities of interest are
separated from side activities by acid digestion and ion exchange. The
technique has been applied to study the liquid scintillator used in the KamLAND
neutrino experiment. Detection limits of <2.4X10**-15 g 40K/g LS, <5.5X10**-15
g Th/g LS, and <8X10**-15 g U/g LS have been achieved.Comment: 16 pages, 3 figures, accepted for publication in Nuclear Instruments
and Methods
First Measurement of the Neutron -Asymmetry with Ultracold Neutrons
We report the first measurement of angular correlation parameters in neutron
-decay using polarized ultracold neutrons (UCN). We utilize UCN with
energies below about 200 neV, which we guide and store for s in a Cu
decay volume. The potential of a static 7 T field
external to the decay volume provides a 420 neV potential energy barrier to the
spin state parallel to the field, polarizing the UCN before they pass through
an adiabatic fast passage (AFP) spin-flipper and enter a decay volume, situated
within a 1 T, superconducting solenoidal spectrometer. We
determine a value for the -asymmetry parameter , proportional to
the angular correlation between the neutron polarization and the electron
momentum, of .Comment: 4 pages, 2 figures, 1 table, submitted to Phys. Rev. Let
Parity-violating Electron Deuteron Scattering and the Proton's Neutral Weak Axial Vector Form Factor
We report on a new measurement of the parity-violating asymmetry in
quasielastic electron scattering from the deuteron at backward angles at Q2=
0.038 (GeV/c)2. This quantity provides a determination of the neutral weak
axial vector form factor of the nucleon, which can potentially receive large
electroweak corrections. The measured asymmetry A=-3.51 +/- 0.57(stat) +/-
0.58(sys)ppm is consistent with theoretical predictions. We also report on
updated results of the previous experiment at Q2=0.091 (GeV/c)2, which are also
consistent with theoretical predictions.Comment: 4 pages, 2 figures, submitted to Phys. Rev. Let
Dietary Supplements and Sports Performance: Amino Acids
This is the third in a series of six articles to discuss the major classes of dietary supplements (vitamins; minerals; amino acids; herbs or botanicals; metabolites, constituents/extracts, or combinations). The major focus is on efficacy of such dietary supplements to enhance exercise or sport performance
Parity-violating Electron Deuteron Scattering and the Proton's Neutral Weak Axial Vector Form Factor
We report on a new measurement of the parity-violating asymmetry in
quasielastic electron scattering from the deuteron at backward angles at Q2=
0.038 (GeV/c)2. This quantity provides a determination of the neutral weak
axial vector form factor of the nucleon, which can potentially receive large
electroweak corrections. The measured asymmetry A=-3.51 +/- 0.57(stat) +/-
0.58(sys)ppm is consistent with theoretical predictions. We also report on
updated results of the previous experiment at Q2=0.091 (GeV/c)2, which are also
consistent with theoretical predictions.Comment: 4 pages, 2 figures, submitted to Phys. Rev. Let
Final results for the neutron β-asymmetry parameter A₀ from the UCNA experiment
The UCNA experiment was designed to measure the neutron β-asymmetry parameter A0 using polarized ultracold neutrons (UCN). UCN produced via downscattering in solid deuterium were polarized via transport through a 7 T magnetic field, and then directed to a 1 T solenoidal electron spectrometer, where the decay electrons were detected in electron detector packages located on the two ends of the spectrometer. A value for A0 was then extracted from the asymmetry in the numbers of counts in the two detector packages. We summarize all of the results from the UCNA experiment, obtained during run periods in 2007, 2008–2009, 2010, and 2011–2013, which ultimately culminated in a 0.67% precision result for A₀
- …