8 research outputs found

    Validation of the oxygen desaturation index in the diagnostic workup of obstructive sleep apnea

    Get PDF
    Introduction: Obstructive sleep apnea (OSA) is common, and diagnosis requires expensive and laborious testing to assess the apnea hypopnea index (AHI). We performed an analysis to explore the relationship between the oxygen desaturation index (ODI) as measured with pulse oximetry and the AHI in our large portable monitoring (PM) database to find an optimal cutoff value for the ODI in order to be able to exclude AHI ≥ 5 on PM. Methods: Three thousand four hundred thirteen PM recordings were randomly divided into a training set (N = 2281) and a test set (N = 1132). The optimal cutoff for the ODI to exclude an AHI ≥ 5 on PM was determined in the training set and subsequently validated in the test set. Results: Area under the curve of the ODI to exclude an AHI ≥ 5 on PM was 0.997 in the training set and 0.996 in the test set. In the training set, the optimal cutoff to predict an AHI < 5 was an ODI < 5. Using this cutoff in the test set provided a sensitivity of 97.7%, a specificity of 97.0%, a positive predictive value of 99.2%, and a negative predictive value of 91.4%. Conclusion: An ODI < 5 predicts an AHI < 5 with high sensitivity and specificity when measured simultaneously using the same oximeter during PM recording

    Reproducibility of hypercapnic ventilatory response measurements with steady-state and rebreathing methods

    No full text
    In this study, the hypercapnic ventilatory response (HCVR) was measured, defined as the ventilation response to carbon dioxide tension (PCO2). We investigated which method, rebreathing or steady-state, is most suitable for measurement of the HCVR in healthy subjects, primarily based on reproducibility. Secondary outcome parameters were subject experience and duration. 20 healthy adults performed a rebreathing and steady-state HCVR measurement on two separate days. Subject experience was assessed using numeric rating scales (NRS). The intraclass correlation coefficient (ICCs) of the sensitivity to carbon dioxide above the ventilatory recruitment threshold and the projected apnoea threshold were calculated to determine the reproducibility of both methods. The ICCs of sensitivity were 0.89 (rebreathing) and 0.56 (steady-state). The ICCs of the projected apnoea threshold were 0.84 (rebreathing) and 0.25 (steady-state). The steady-state measurement was preferred by 16 out of 20 subjects; the differences in NRS scores were small. The hypercapnic ventilatory response measured using the rebreathing setup provided reproducible results, while the steady-state method did not. This may be explained by high variability in end-tidal PCO2. Differences in subject experience between the methods are small

    Reproducibility of hypercapnic ventilatory response measurements with steady-state and rebreathing methods

    Get PDF
    In this study, the hypercapnic ventilatory response (HCVR) was measured, defined as the ventilation response to carbon dioxide tension (PCO2). We investigated which method, rebreathing or steady-state, is most suitable for measurement of the HCVR in healthy subjects, primarily based on reproducibility. Secondary outcome parameters were subject experience and duration. 20 healthy adults performed a rebreathing and steady-state HCVR measurement on two separate days. Subject experience was assessed using numeric rating scales (NRS). The intraclass correlation coefficient (ICCs) of the sensitivity to carbon dioxide above the ventilatory recruitment threshold and the projected apnoea threshold were calculated to determine the reproducibility of both methods. The ICCs of sensitivity were 0.89 (rebreathing) and 0.56 (steady-state). The ICCs of the projected apnoea threshold were 0.84 (rebreathing) and 0.25 (steady-state). The steady-state measurement was preferred by 16 out of 20 subjects; the differences in NRS scores were small. The hypercapnic ventilatory response measured using the rebreathing setup provided reproducible results, while the steady-state method did not. This may be explained by high variability in end-tidal PCO2. Differences in subject experience between the methods are small

    Retrospective validation of a new volumetric capnography parameter for the exclusion of pulmonary embolism at the emergency department

    Get PDF
    Volumetric capnography might be used to exclude pulmonary embolism (PE) without the need for computed tomography pulmonary angiography. In a pilot study, a new parameter (CapNoPE) combining the amount of carbon dioxide exhaled per breath (carbon dioxide production (VCO2)), the slope of phase 3 of the volumetric capnogram (slope 3) and respiratory rate (RR) showed promising diagnostic accuracy (where CapNoPE=(VCO2×slope 3)/RR). To retrospectively validate CapNoPE for the exclusion of PE, the volumetric capnograms of 205 subjects (68 with PE) were analysed, based on a large multicentre dataset of volumetric capnograms from subjects with suspected PE at the emergency department. The area under the curve (AUC) of the receiver operating characteristic (ROC) curve and diagnostic accuracy of the in-pilot established threshold (1.90 Pa·min) were calculated. CapNoPE was 1.56±0.97 Pa·min in subjects with PE versus 2.51±1.67 Pa·min in those without PE (p<0.001). The AUC of the ROC curve was 0.714 (95% CI 0.64–0.79). For the cut-off of ≥1.90 Pa·min, sensitivity was 64.7%, specificity was 59.9%, the negative predictive value was 77.4% and the positive predictive value was 44.4%. The CapNoPE parameter is decreased in patients with PE but its diagnostic accuracy seems too low to use in clinical practice