2,994 research outputs found
Direct Determination of the Kinetics of Oxygen Diffusion to the Photocytes of a Bioluminescent Elaterid Larva, Measurement of Gas- and Aqueous-Phase Diffusional Barriers and Modelling of Oxygen Supply
We describe the development and use of a direct kinetic technique to determine the time taken for oxygen to diffuse from the external environment into the light-producing cells (photocytes) in the prothorax of bioluminescent larvae of Pyrearinus termitilluminans. This was achieved by measuring the time course of the pseudoflash induced through sequential anoxia followed by normoxia. We have also determined the separate times taken for this oxygen diffusion in gaseous and tissue (predominantly aqueous) phases by using helium and nitrogen as the carrier gas. Of the total time taken for diffusion, that in the gas phase required 613+/-136 ms (mean +/- s.e. m., N=5) whilst that in the aqueous phase required 1313+/-187 ms. These values imply pathlengths of diffusion in the gaseous and aqueous phases of 4.80x10(-)(3)+/-0.53x10(-)(3) and 8. 89x10(-)(5)+/-0.61x10(-)(5 )m, respectively. In addition, the pathlength of gas-phase diffusion was used to derive a parameter relating to the tortuosity of the tracheal system. These values, together with those obtained upon bioluminescent oxygen consumption, have been used to model oxygen supply to the photocyte. From these studies, it would also appear that the modulation of tracheolar fluid levels might be a significant mechanism of control of tissue oxygen levels in at least some insects
Strangeness production in jets from p+p \sqrt{s} = 200 GeV collisions
Measurements of strangeness production in jets help illuminate the QCD
mechanisms in fragmentation. Furthermore, they provide a crucial baseline for
heavy-ion studies where modifications in jet chemistry have recently been
predicted. We present new results on strange particle production in jets from
p+p \sqrt{s} = 200 GeV collisions measured by the STAR experiment. The momentum
distributions of the \Lambda, \bar{\Lambda} and K0Short particles are obtained
using various jet finding algorithms, and then compared to various models.
Strange particle ratios in jets are obtained and compared to values obtained
from the inclusive spectra. Finally, we show jets tagged with leading strange
baryons and mesons, in order to investigate whether gluon or quark jets can be
isolated in this way.Comment: 5 pages, 4 figures, Winter Workshop on Nuclear Dynamics 2010, Jamaic
Firefly Flashing is Controlled by Gating Oxygen to Light-Emitting Cells
Although many aspects of firefly bioluminescence are understood, the mechanism by which adult fireflies produce light as discrete rapid flashes is not. Here we examine the most postulated theory, that flashing is controlled by gating oxygen access to the light-emitting cells (photocytes). According to this theory, the dark state represents repression of bioluminescence by limiting oxygen, which is required for bioluminescence; relief from this repression by transiently allowing oxygen access to the photocytes allows the flash. We show that normobaric hyperoxia releases the repression of light emission in the dark state of both spontaneously flashing and non-flashing fireflies, causing continual glowing, and we measure the kinetics of this process. Secondly, we determine the length of the barriers to oxygen diffusion to the photocytes in the aqueous and gas phases. Thirdly, we provide constraints upon the distance between any gas-phase gating structure(s) and the photocytes. We conclude from these data that the flash of the adult firefly is controlled by gating of oxygen to the photocytes, and demonstrate that this control mechanism is likely to act by modulating the levels of fluid in the tracheoles supplying photocytes, providing a variable barrier to oxygen diffusion
Measurement of Oxygen Partial Pressure, its Control During Hypoxia and Hyperoxia, and its Effect upon Light Emission in a Bioluminescent Elaterid Larva
This study investigates the respiratory physiology of bioluminescent larvae of Pyrearinus termitilluminans in relation to their tolerance to hypoxia and hyperoxia and to the supply of oxygen for bioluminescence. The partial pressure of oxygen (P(O2)) was measured within the bioluminescent prothorax by in vivo electron paramagnetic resonance (EPR) oximetry following acclimation of larvae to hypoxic, normoxic and hyperoxic (normobaric) atmospheres and during periods of bioluminescence (during normoxia). The P(O2) in the prothorax during exposure to an external P(O2) of 15.2, 160 and 760 mmHg was 10.3+/-2.6, 134+/-0.9 and 725+/-73 mmHg respectively (mean +/- s.d., N=5; 1 mmHg=0.1333 kPa). Oxygen supply to the larvae via gas exchange through the spiracles, measured by determining the rate of water loss, was also studied in the above atmospheres and was found not to be dependent upon P(O2). The data indicated that there is little to no active control of extracellular tissue P(O2) within the prothorax of these larvae. The reduction in prothorax P(O2) observed during either attack-response-provoked bioluminescence or sustained feeding-related bioluminescence in a normoxic atmosphere was variable, but fell within the range 10-25 mmHg. The effect of hypoxic atmospheres on bioluminescence was measured to estimate the intracellular P(O2) within the photocytes of the prothorax. Above a threshold value of 50-80 mmHg, bioluminescence was unaffected by P(O2). Below this threshold, an approximately linear relationship between P(O2) and bioluminescence was observed. Taken together with the extracellular P(O2) measurements, this suggests that control of P(O2) within the photocyte may occur. This work establishes that EPR oximetry is a valuable technique for long-term measurement of tissue P(O2) in insects and can provide valuable insights into their respiratory physiology. It also raises questions regarding the hypothesis that bioluminescence can have a significant antioxidative effect by reduction of prothorax P(O2 )through oxygen consumption
Fluctuation and flow probes of early-time correlations in relativistic heavy ion collisions
Fluctuation and correlation observables are often measured using
multi-particle correlation methods and therefore mutually probe the origins of
genuine correlations present in multi-particle distribution functions. We
investigate the common influence of correlations arising from the spatially
inhomogeneous initial state on multiplicity and momentum fluctuations as well
as flow fluctuations. Although these observables reflect different aspects of
the initial state, taken together, they can constrain a correlation scale set
at the earliest moments of the collision. We calculate both the correlation
scale in an initial stage Glasma flux tube picture and the modification to
these correlations from later stage hydrodynamic flow and find quantitative
agreement with experimental measurements over a range of collision systems and
energies.Comment: Proceedings of the 28th Winter Workshop on Nuclear Dynamics, Dorado
del Mar, Puerto Rico, April 7-14, 201
The Zel'dovich effect and evolution of atomic Rydberg spectra along the Periodic Table
In 1959 Ya. B. Zel'dovich predicted that the bound-state spectrum of the
non-relativistic Coulomb problem distorted at small distances by a short-range
potential undergoes a peculiar reconstruction whenever this potential alone
supports a low-energy scattering resonance. However documented experimental
evidence of this effect has been lacking. Previous theoretical studies of this
phenomenon were confined to the regime where the range of the short-ranged
potential is much smaller than Bohr's radius of the Coulomb field. We go beyond
this limitation by restricting ourselves to highly-excited s states. This
allows us to demonstrate that along the Periodic Table of elements the
Zel'dovich effect manifests itself as systematic periodic variation of the
Rydberg spectra with a period proportional to the cubic root of the atomic
number. This dependence, which is supported by analysis of experimental and
numerical data, has its origin in the binding properties of the ionic core of
the atom.Comment: 17 pages, 12 figure
Hamstring muscle-tendon geometric adaptations to resistance training using the hip extension and Nordic hamstring exercises
Targeted resistance training stimulates hamstring muscle hypertrophy, but its effect on tendon-aponeurosis geometry is unknown. This study examined changes in hamstring muscle, free tendon, and aponeurosis geometry following a 10?week Nordic or hip extension exercise intervention. Thirty recreationally active males were randomly allocated (n?=?10 per group) to a Nordic, hip extension, or control group. Magnetic resonance imaging of both thighs was acquired pre- and post-intervention. Changes in free tendon and aponeurosis volume for each hamstring muscle, biceps femoris long head (BFlh) aponeurosis interface area and muscle volume-to-interface area ratio were compared between groups. Regional changes in muscle CSA were examined via statistical parametric mapping. The change in semimembranosus free tendon volume was greater for the Nordic than control group (mean difference?=?0.06?cm3, 95% CI?=?0.02?0.11?cm3). No significant between-group differences existed for other hamstring free tendons or aponeuroses. There were no between-group differences in change in BFlh interface area. Change in BFlh muscle volume-to-interface area ratio was greater in the hip extension than Nordic (mean difference?=?0.10, 95% CI?=?0.007?0.19, p?=?0.03) and control (mean difference?=?0.12, 95% CI?=?0.03?0.22, p?=?0.009) groups. Change in muscle CSA following training was greatest in the mid-portion of semitendinosus for both intervention groups, and the mid-portion of BFlh for the hip extension group. There was limited evidence for tendon-aponeurosis hypertrophy after 10?weeks of training with the Nordic or hip extension exercises. For the BFlh, neither intervention altered the interface area although hip extension training stimulated an increase in the muscle volume-to-interface area ratio, which may have implications for localized tissue strains. Alternative muscle-tendon loading strategies appear necessary to stimulate hamstring tendon adaptations
VHMPID: a new detector for the ALICE experiment at LHC
This article presents the basic idea of VHMPID, an upgrade detector for the
ALICE experiment at LHC, CERN. The main goal of this detector is to extend the
particle identification capabilities of ALICE to give more insight into the
evolution of the hot and dense matter created in Pb-Pb collisions. Starting
from the physics motivations and working principles the challenges and current
status of development is detailed.Comment: 4 pages, 6 figures. To be published in EPJ Web of Conference
A wider Europe? The view from Russia, Belarus and Ukraine
On the evidence of national surveys conducted between 2000 and 2006, there is a declining sense of European self-identity in the three Slavic post-Soviet republics of Russia, Belarus and Ukraine. Attitudes towards the European Union and the possibility of membership are broadly supportive, but with a substantial proportion who find it difficult to express a view, and substantial proportions are poorly informed in comparison with the general public in EU member or prospective member countries. Those who are better informed are more likely to favour EU membership and vice versa. Generally, socioeconomic characteristics (except for age and region) are relatively poor predictors of support for EU membership as compared with attitudinal variables. But ‘Europeanness’ should not be seen as a given, and much will depend on whether EU member countries emphasize what is common to east and west or establish ‘new dividing lines’ in place of those of the cold war
Recommended from our members
Liquid membrane system for the removal and concentration of transuranic elements
The goal of this program is to develop an efficient, reliable, and radiation-resistant modified liquid membrane system (MLMS) for the selective removal and concentration of transuranic elements (TRUs) and strontium-90 from dissolved Hanford sludge wastes. The efforts are divided into three categories: (1) demonstration and optimization of the MLMS for the TRUEX and SREX processes using simulant waste solution; (2) development of a radiation-resistant microporous divider and membrane module for testing with actual waste solutions; and (3) demonstration of the MLMS for the TRUEX and SREX processes using actual Hanford waste. Successful completion of these development efforts will yield a compact, versatile, and reliable MLMS for implementation with the TRUEX and SREX processes. The MLMS is simple, stable, more efficient, and easier to control and operate than conventional solvent-extraction processes, such as those employing centrifugal contactors. In addition, the MLMS process offers operational cost savings over the conventional technology, by exhibiting at least a 10% reduction in the consumption of extractant chemicals
- …