159 research outputs found

    Enantioselective Tail-to-Head Terpene Cyclizations by Optically Active Hexameric Resorcin[4]arene Capsule Derivatives

    Get PDF
    Molecular capsules enable the conversion of substrates inside a closed cavity, mimicking to some extent enzymatic catalysis. Chirality transfer from the molecular capsule onto the encapsulated substrate has been only studied in a few cases. Here we demonstrate that chirality transfer is possible inside a rather large molecular container of approximately 1400 Å3. Specifically, we present 1) the first examples of optically active hexameric resorcin[4]arene capsules, 2) their ability to enantioselectively catalyze tail-to-head terpene cyclizations, and 3) the surprisingly high sensitivity of enantioselectivity on the structural modifications

    Overriding Intrinsic Reactivity in Aliphatic C−H Oxidation: Preferential C3/C4 Oxidation of Aliphatic Ammonium Substrates

    Get PDF
    The site-selective C−H oxidation of unactivated positions in aliphatic ammonium chains poses a tremendous synthetic challenge, for which a solution has not yet been found. Here, we report the preferential oxidation of the strongly deactivated C3/C4 positions of aliphatic ammonium substrates by employing a novel supramolecular catalyst. This chimeric catalyst was synthesized by linking the well-explored catalytic moiety Fe(pdp) to an alkyl ammonium binding molecular tweezer. The results highlight the vast potential of overriding the intrinsic reactivity in chemical reactions by guiding catalysis using supramolecular host structures that enable a precise orientation of the substrates

    Elucidating the Importance of Hydrochloric Acid as a Cocatalyst for Resorcinarene-Capsule-Catalyzed reactions

    Get PDF
    This survey of resorcinarene‐capsule‐catalyzed reactions demonstrates that HCl functions as a crucial cocatalyst by increasing the capsule's inherent Brønsted acidity to enable or accelerate cationic reactions. The presence of HCl appears to be without consequences for other reactions

    Discovering Monoterpene Catalysis Inside Nanocapsules with Multiscale Modeling and Experiments

    Get PDF
    Large-scale production of natural products, such as terpenes, presents a significant scientific and technological challenge. One promising approach to tackle this problem is chemical synthesis inside nanocapsules, although enzyme-like control of such chemistry has not yet been achieved. In order to better understand the complex chemistry inside nanocapsules, we design a multiscale nanoreactor simulation approach. The nanoreactor simulation protocol consists of hybrid quantum mechanics-molecular mechanics-based high temperature Langevin molecular dynamics simulations. Using this approach we model the tail-to-head formation of monoterpenes inside a resorcin[4]arene-based capsule (capsule I ). We provide a rationale for the experimentally observed kinetics of monoterpene product formation and product distribution using capsule I , and we explain why additional stable monoterpenes, like camphene, are not observed. On the basis of the in-capsule I simulations, and mechanistic insights, we propose that feeding the capsule with pinene can yield camphene, and this proposal is verified experimentally. This suggests that the capsule may direct the dynamic reaction cascades by virtue of π-cation interactions

    High-fidelity transmission of entanglement over a high-loss freespace channel

    Full text link
    Quantum entanglement enables tasks not possible in classical physics. Many quantum communication protocols require the distribution of entangled states between distant parties. Here we experimentally demonstrate the successful transmission of an entangled photon pair over a 144 km free-space link. The received entangled states have excellent, noise-limited fidelity, even though they are exposed to extreme attenuation dominated by turbulent atmospheric effects. The total channel loss of 64 dB corresponds to the estimated attenuation regime for a two-photon satellite quantum communication scenario. We confirm that the received two-photon states are still highly entangled by violating the CHSH inequality by more than 5 standard deviations. From a fundamental point of view, our results show that the photons are virtually not subject to decoherence during their 0.5 ms long flight through air, which is encouraging for future world-wide quantum communication scenarios.Comment: 5 pages, 3 figures, replaced paper with published version, added journal referenc

    Correlated Strength in Nuclear Spectral Function

    Full text link
    We have carried out an (e,e'p) experiment at high momentum transfer and in parallel kinematics to measure the strength of the nuclear spectral function S(k,E) at high nucleon momenta k and large removal energies E. This strength is related to the presence of short-range and tensor correlations, and was known hitherto only indirectly and with considerable uncertainty from the lack of strength in the independent-particle region. This experiment confirms by direct measurement the correlated strength predicted by theory.Comment: 4 pages, 2 figures, accepted by Phys. Rev. Let

    Transcatheter Implantation of the MONARC Coronary Sinus Device for Mitral Regurgitation 1-Year Results From the EVOLUTION Phase I Study (Clinical Evaluation of the Edwards Lifesciences Percutaneous Mitral Annuloplasty System for The Treatment of Mitral Regurgitation)

    Get PDF
    ObjectivesThis study sought to assess the safety and efficacy of transcatheter valve annuloplasty in patients with mitral regurgitation (MR).BackgroundMitral regurgitation is associated with a worsened prognosis in patients with dilated cardiomyopathy. Surgical mitral annuloplasty reduces the septal-lateral dimension of the mitral annulus resulting in improved leaflet coaptation with a reduction in regurgitation. Percutaneous annuloplasty with the MONARC device (Edwards Lifesciences, Irvine, California) implanted within the coronary sinus is designed to reduce mitral regurgitation through a similar mechanism.MethodsA total of 72 patients with MR grade ≥2 were enrolled at 8 participating centers in 4 countries. Clinical evaluation and transthoracic echocardiography were performed at baseline and at 3, 6, and 12 months. Multislice cardiac computed tomography and coronary angiography were performed at baseline and 3 months.ResultsThe MONARC device was implanted in 59 of 72 patients (82%). The primary safety end point (freedom from death, tamponade, or myocardial infarction at 30 days) was met in 91% of patients at 30 days and in 82% at 1 year. Computed tomography imaging documented passage of the great cardiac vein over an obtuse marginal artery in 55% of patients and was associated with angiographic coronary artery compression in 15 patients and myocardial infarction in 2 patients (3.4%). At 12 months, a reduction in MR by ≥1 grade was observed in 50.0% of 22 implanted patients with matched echocardiograms and in 85.7% of 7 patients with baseline MR grade ≥3.ConclusionsImplantation of the MONARC device in the coronary sinus is feasible and may reduce MR. However, coronary artery compression may occur in patients in whom the great cardiac vein passes over a coronary artery, necessitating strategies in future studies to avoid this occurrence

    Functional intercomparison of intraoperative radiotherapy equipment – Photon Radiosurgery System

    Get PDF
    BACKGROUND: Intraoperative Radiotherapy (IORT) is a method by which a critical radiation dose is delivered to the tumour bed immediately after surgical excision. It is being investigated whether a single high dose of radiation will impart the same clinical benefit as a standard course of external beam therapy. Our centre has four Photon Radiosurgery Systems (PRS) currently used to irradiate breast and neurological sites. MATERIALS AND METHODS: The PRS comprises an x-ray generator, control console, quality assurance tools and a mobile gantry. We investigated the dosimetric characteristics of each source and its performance stability over a period of time. We investigated half value layer, output diminution factor, internal radiation monitor (IRM) reproducibility and depth-doses in water. The half value layer was determined in air by the broad beam method, using high purity aluminium attenuators. To quantify beam hardening at clinical depths, solid water attenuators of 5 and 10 mm were placed between the x-ray probe and attenuators. The ion chamber current was monitored over 30 minutes to deduce an output diminution factor. IRM reproducibility was investigated under various exposures. Depth-dose curves in water were obtained at distances up to 35 mm from the probe. RESULTS: The mean energies for the beam attenuated by 5 and 10 mm of solid water were derived from ICRU Report 17 and found to be 18 and 24 keV. The average output level over a period of 30 minutes was found to be 99.12%. The average difference between the preset IRM limit and the total IRM count was less than 0.5%. For three x-ray sources, the average difference between the calculated and actual treatment times was found to be 0.62% (n = 30). The beam attenuation in water varied by approximately 1/r(3). CONCLUSION: The x-ray sources are stable over time. Most measurements were found to lie within the manufacturer's tolerances and an intercomparison of these checks suggests that the four x-ray sources have similar performance characteristics

    Cometary dust analogues for physics experiments

    Get PDF
    The CoPhyLab (Cometary Physics Laboratory) project is designed to study the physics of comets through a series of earth-based experiments. For these experiments, a dust analogue was created with physical properties comparable to those of the non-volatile dust found on comets. This "CoPhyLab dust" is planned to be mixed with water and CO2_2 ice and placed under cometary conditions in vacuum chambers to study the physical processes taking place on the nuclei of comets. In order to develop this dust analogue, we mixed two components representative for the non-volatile materials present in cometary nuclei. We chose silica dust as representative for the mineral phase and charcoal for the organic phase, which also acts as a darkening agent. In this paper, we provide an overview of known cometary analogues before presenting measurements of eight physical properties of different mixtures of the two materials and a comparison of these measurements with known cometary values. The physical properties of interest are: particle size, density, gas permeability, spectrophotometry, mechanical, thermal and electrical properties. We found that the analogue dust that matches the highest number of physical properties of cometary materials consists of a mixture of either 60\%/40\% or 70\%/30\% of silica dust/charcoal by mass. These best-fit dust analogue will be used in future CoPhyLab experiments
    corecore