8 research outputs found

    Integrated motor drives: state of the art and future trends

    Get PDF
    With increased need for high power density, high efficiency and high temperature capabilities in Aerospace and Automotive applications, Integrated Motor Drives (IMD) offers a potential solution. However, close physical integration of the converter and the machine may also lead to an increase in components temperature. This requires careful mechanical, structural and thermal analysis; and design of the IMD system. This paper reviews existing IMD technologies and their thermal effects on the IMD system. The effects of the power electronics (PE) position on the IMD system and its respective thermal management concepts are also investigated. The challenges faced in designing and manufacturing of an IMD along with the mechanical and structural impacts of close physical integration is also discussed and potential solutions are provided. Potential converter topologies for an IMD like the Matrix converter, 2-level Bridge, 3-level NPC and Multiphase full bridge converters are also reviewed. Wide band gap devices like SiC and GaN and their packaging in power modules for IMDs are also discussed. Power modules components and packaging technologies are also presented

    Use of a novel electronic maternal surveillance system to generate automated alerts on the labor and delivery unit

    No full text
    Abstract Background Maternal early warning systems reduce maternal morbidity. We developed an electronic maternal surveillance system capable of visually summarizing the labor and delivery census and identifying changes in clinical status. Automatic page alerts to clinical providers, using an algorithm developed at our institution, were incorporated in an effort to improve early detection of maternal morbidity. We report the frequency of pages generated by the system. To our knowledge, this is the first time such a system has been used in peripartum care. Methods Alert criteria were developed after review of maternal early warning systems, including the Maternal Early Warning Criteria (MEWC). Careful consideration was given to the frequency of pages generated by the surveillance system. MEWC notification criteria were liberalized and a paging algorithm was created that triggered paging alerts to first responders (nurses) and then managing services due to the assumption that paging all clinicians for each vital sign triggering MEWC would generate an inordinate number of pages. For preliminary analysis, to determine the effect of our automated paging algorithm on alerting frequency, the paging frequency of this system was compared to the frequency of vital signs meeting the Maternal Early Warning Criteria (MEWC). This retrospective analysis was limited to a sample of 34 patient rooms uniquely capable of storing every vital sign reported by the bedside monitor. Results Over a 91-day period, from April 1 to July 1, 2017, surveillance was conducted from 64 monitored beds, and the obstetrics service received one automated page every 2.3 h. The most common triggers for alerts were for hypertension and tachycardia. For the subset of 34 patient rooms uniquely capable of real-time recording, one vital sign met the MEWC every 9.6 to 10.3 min. Anecdotally, the system was well-received. Conclusions This novel electronic maternal surveillance system is designed to reduce cognitive bias and improve timely clinical recognition of maternal deterioration. The automated paging algorithm developed for this software dramatically reduces paging frequency compared to paging for isolated vital sign abnormalities alone. Long-term, prospective studies will be required to determine its impact on patient outcomes

    Risk of Epidural Hematoma after Neuraxial Techniques in Thrombocytopenic Parturients A Report from the Multicenter Perioperative Outcomes Group

    No full text
    Background: Thrombocytopenia has been considered a relative or even absolute contraindication to neuraxial techniques due to the risk of epidural hematoma. There is limited literature to estimate the risk of epidural hematoma in thrombocytopenic parturients. The authors reviewed a large perioperative database and performed a systematic review to further define the risk of epidural hematoma requiring surgical decompression in this population. Methods: The authors performed a retrospective cohort study using the Multicenter Perioperative Outcomes Group database to identify thrombocytopenic parturients who received a neuraxial technique and to estimate the risk of epidural hematoma. Patients were stratified by platelet count, and those requiring surgical decompression were identified. A systematic review was performed, and risk estimates were combined with those from the existing literature. Results: A total of 573 parturients with a platelet count less than 100,000 mm(-3) who received a neuraxial technique across 14 institutions were identified in the Multicenter Perioperative Outcomes Group database, and a total of 1,524 parturients were identified after combining the data from the systematic review. No cases of epidural hematoma requiring surgical decompression were observed. The upper bound of the 95% CI for the risk of epidural hematoma for a platelet count of 0 to 49,000 mm(-3) is 11%, for 50,000 to 69,000 mm(-3) is 3%, and for 70,000 to 100,000 mm(-3) is 0.2%. Conclusions: The number of thrombocytopenic parturients in the literature who received neuraxial techniques without complication has been significantly increased. The risk of epidural hematoma associated with neuraxial techniques in parturients at a platelet count less than 70,000 mm(-3) remains poorly defined due to limited observation

    Exploring various polygenic risk scores for skin cancer in the phenomes of the Michigan genomics initiative and the UK Biobank with a visual catalog: PRSWeb.

    No full text
    Polygenic risk scores (PRS) are designed to serve as single summary measures that are easy to construct, condensing information from a large number of genetic variants associated with a disease. They have been used for stratification and prediction of disease risk. The primary focus of this paper is to demonstrate how we can combine PRS and electronic health records data to better understand the shared and unique genetic architecture and etiology of disease subtypes that may be both related and heterogeneous. PRS construction strategies often depend on the purpose of the study, the available data/summary estimates, and the underlying genetic architecture of a disease. We consider several choices for constructing a PRS using data obtained from various publicly-available sources including the UK Biobank and evaluate their abilities to predict not just the primary phenotype but also secondary phenotypes derived from electronic health records (EHR). This study was conducted using data from 30,702 unrelated, genotyped patients of recent European descent from the Michigan Genomics Initiative (MGI), a longitudinal biorepository effort within Michigan Medicine. We examine the three most common skin cancer subtypes in the USA: basal cell carcinoma, cutaneous squamous cell carcinoma, and melanoma. Using these PRS for various skin cancer subtypes, we conduct a phenome-wide association study (PheWAS) within the MGI data to evaluate PRS associations with secondary traits. PheWAS results are then replicated using population-based UK Biobank data and compared across various PRS construction methods. We develop an accompanying visual catalog called PRSweb that provides detailed PheWAS results and allows users to directly compare different PRS construction methods

    Succinylcholine use and dantrolene availability for malignant hyperthermia treatment: Database analyses and systematic review

    No full text
    Editor\u27s Perspective What We Already Know about This Topic Dantrolene effectively treats malignant hyperthermia, but there are discrepant recommendations for dantrolene availability in facilities that stock succinylcholine for airway rescue but do not use volatile anesthetics. What This Article Tells Us That Is New The authors performed an analysis of data from three databases and a systematic literature review. Providers frequently use succinylcholine, including during difficult mask ventilation. Succinylcholine given without volatile anesthetics triggered 24 malignant hyperthermia events, 13 of which were treated with dantrolene. Fourteen patients experienced substantial complications, and one died. Delayed dantrolene treatment worsened patient outcomes. Background: Although dantrolene effectively treats malignant hyperthermia (MH), discrepant recommendations exist concerning dantrolene availability. Whereas Malignant Hyperthermia Association of the United States guidelines state dantrolene must be available within 10 min of the decision to treat MH wherever volatile anesthetics or succinylcholine are administered, a Society for Ambulatory Anesthesia protocol permits Class B ambulatory facilities to stock succinylcholine for airway rescue without dantrolene. The authors investigated (1) succinylcholine use rates, including for airway rescue, in anesthetizing/sedating locations; (2) whether succinylcholine without volatile anesthetics triggers MH warranting dantrolene; and (3) the relationship between dantrolene administration and MH morbidity/mortality. Methods: The authors performed focused analyses of the Multicenter Perioperative Outcomes Group (2005 through 2016), North American MH Registry (2013 through 2016), and Anesthesia Closed Claims Project (1970 through 2014) databases, as well as a systematic literature review (1987 through 2017). The authors used difficult mask ventilation (grades III and IV) as a surrogate for airway rescue. MH experts judged dantrolene treatment. For MH morbidity/mortality analyses, the authors included U.S. and Canadian cases that were fulminant or scored 20 or higher on the clinical grading scale and in which volatile anesthetics or succinylcholine were given. Results: Among 6,368,356 queried outcomes cases, 246,904 (3.9%) received succinylcholine without volatile agents. Succinylcholine was used in 46% (n = 710) of grade IV mask ventilation cases (median dose, 100 mg, 1.2 mg/kg). Succinylcholine without volatile anesthetics triggered 24 MH cases, 13 requiring dantrolene. Among 310 anesthetic-triggered MH cases, morbidity was 20 to 37%. Treatment delay increased complications every 10 min, reaching 100% with a 50-min delay. Overall mortality was 1 to 10%; 15 U.S. patients died, including 4 after anesthetics in freestanding facilities. Conclusions: Providers use succinylcholine commonly, including during difficult mask ventilation. Succinylcholine administered without volatile anesthetics may trigger MH events requiring dantrolene. Delayed dantrolene treatment increases the likelihood of MH complications. The data reported herein support stocking dantrolene wherever succinylcholine or volatile anesthetics may be used

    Risk of Epidural Hematoma after Neuraxial Techniques in Thrombocytopenic Parturients : A Report from the Multicenter Perioperative Outcomes Group

    No full text
    BACKGROUND:: Thrombocytopenia has been considered a relative or even absolute contraindication to neuraxial techniques due to the risk of epidural hematoma. There is limited literature to estimate the risk of epidural hematoma in thrombocytopenic parturients. The authors reviewed a large perioperative database and performed a systematic review to further define the risk of epidural hematoma requiring surgical decompression in this population. METHODS:: The authors performed a retrospective cohort study using the Multicenter Perioperative Outcomes Group database to identify thrombocytopenic parturients who received a neuraxial technique and to estimate the risk of epidural hematoma. Patients were stratified by platelet count, and those requiring surgical decompression were identified. A systematic review was performed, and risk estimates were combined with those from the existing literature. RESULTS:: A total of 573 parturients with a platelet count less than 100,000 mm who received a neuraxial technique across 14 institutions were identified in the Multicenter Perioperative Outcomes Group database, and a total of 1,524 parturients were identified after combining the data from the systematic review. No cases of epidural hematoma requiring surgical decompression were observed. The upper bound of the 95% CI for the risk of epidural hematoma for a platelet count of 0 to 49,000 mm is 11%, for 50,000 to 69,000 mm is 3%, and for 70,000 to 100,000 mm is 0.2%. CONCLUSIONS:: The number of thrombocytopenic parturients in the literature who received neuraxial techniques without complication has been significantly increased. The risk of epidural hematoma associated with neuraxial techniques in parturients at a platelet count less than 70,000 mm remains poorly defined due to limited observations

    Risk of Epidural Hematoma after Neuraxial Techniques in Thrombocytopenic Parturients : A Report from the Multicenter Perioperative Outcomes Group

    No full text
    BACKGROUND:: Thrombocytopenia has been considered a relative or even absolute contraindication to neuraxial techniques due to the risk of epidural hematoma. There is limited literature to estimate the risk of epidural hematoma in thrombocytopenic parturients. The authors reviewed a large perioperative database and performed a systematic review to further define the risk of epidural hematoma requiring surgical decompression in this population. METHODS:: The authors performed a retrospective cohort study using the Multicenter Perioperative Outcomes Group database to identify thrombocytopenic parturients who received a neuraxial technique and to estimate the risk of epidural hematoma. Patients were stratified by platelet count, and those requiring surgical decompression were identified. A systematic review was performed, and risk estimates were combined with those from the existing literature. RESULTS:: A total of 573 parturients with a platelet count less than 100,000 mm who received a neuraxial technique across 14 institutions were identified in the Multicenter Perioperative Outcomes Group database, and a total of 1,524 parturients were identified after combining the data from the systematic review. No cases of epidural hematoma requiring surgical decompression were observed. The upper bound of the 95% CI for the risk of epidural hematoma for a platelet count of 0 to 49,000 mm is 11%, for 50,000 to 69,000 mm is 3%, and for 70,000 to 100,000 mm is 0.2%. CONCLUSIONS:: The number of thrombocytopenic parturients in the literature who received neuraxial techniques without complication has been significantly increased. The risk of epidural hematoma associated with neuraxial techniques in parturients at a platelet count less than 70,000 mm remains poorly defined due to limited observations
    corecore