52 research outputs found

    Safety of hyperbaric oxygen therapy in mechanically ventilated patients

    Get PDF
    Background: To evaluate the epidemiology of patients who require mechanical ventilation during hyperbaric oxygen therapy. Materials and methods: One-hundred-fifty patients who required mechanical ventilation during hyperbaric oxygen therapy were prospectively studied during a 6-year period in a French university hyperbaric centre. We analysed the indication of hyperbaric oxygen therapy, agent used for sedation, presence of a chest tube, need for vasopressor agents and tolerance and appearance of side effects. Finally, we compared the outcomes of patients according to the presence or absence of acute respiratory distress syndrome (ARDS). Results: Eleven children and 139 adult patients were included (n = 150) in the study. In both populations, carbon monoxide poisoning (51%) and iatrogenic gas embolism (33%) were the two main causes of intubation and mechanical ventilation. The combination of midazolam and sufentanil was used in 85 (67%) patients. All of the patients were given a bolus of a neuromuscular blocker during the hyperbaric session, despite the presence of ARDS in 35 patients. Patient-ventilator asynchrony was the most frequent side effect in 6 (5%) patients and was often the consequence of suboptimal sedation. Mortality was higher in the group with ARDS (23%). Conclusions: Carbon monoxide poisoning and iatrogenic gas embolism are the two main diseases of the patients who required mechanical ventilation during hyperbaric oxygen therapy in this study. Mechanical ventilation is a safe method for patients during hyperbaric oxygen therapy. Sedation needs to be perfected to avoid patient-ventilator asynchrony.

    Effects of lithium on electrical activity and potassium ion distribution in the vertebrate central nervous system

    Get PDF
    Three different regions of the vertebrate central nervous system maintained in vitro (frog spinal cord, guinea pig olfactory cortex and hippocampus) have been used to investigate how Li+ influences membrane potential, membrane resistance, action potentials, synaptic potentials and the transmembrane K+-distribution of neurons and glial cells. In view of the therapeutic action of Li+ in manicdepressive disease, a special effort was made to determine the threshold concentration for the actions of Li+ on the parameters described above. It was observed that Li+ induced a membrane depolarization of both neurons and glial cells, a decrease of action potential amplitudes, a facilitation of monosynaptic excitatory postsynaptic potentials and a depression of polysynaptic reflexes. The membrane resistance of neurons was not altered. Li+ also induced an elevation of the free extracellular potassium concentration and a decrease of the free intracellular potassium concentration. Furthermore, in the presence of Li+ a slowing of the recovery of the membrane potential of neurons and glial cells, and of the extracellular potassium concentration after repetitive synaptic stimulation was observed. The threshold concentrations for the effects of Li+ were below 5 mmol/l in the frog spinal cord and below 2 mmol/l in the guinea pig olfactory cortex and hippocampus. The basic mechanism underlying the action of Li+ may be an interaction with the transport-function of the Na+/K+ pump

    Omecamtiv mecarbil in chronic heart failure with reduced ejection fraction, GALACTIC‐HF: baseline characteristics and comparison with contemporary clinical trials

    Get PDF
    Aims: The safety and efficacy of the novel selective cardiac myosin activator, omecamtiv mecarbil, in patients with heart failure with reduced ejection fraction (HFrEF) is tested in the Global Approach to Lowering Adverse Cardiac outcomes Through Improving Contractility in Heart Failure (GALACTIC‐HF) trial. Here we describe the baseline characteristics of participants in GALACTIC‐HF and how these compare with other contemporary trials. Methods and Results: Adults with established HFrEF, New York Heart Association functional class (NYHA) ≄ II, EF ≀35%, elevated natriuretic peptides and either current hospitalization for HF or history of hospitalization/ emergency department visit for HF within a year were randomized to either placebo or omecamtiv mecarbil (pharmacokinetic‐guided dosing: 25, 37.5 or 50 mg bid). 8256 patients [male (79%), non‐white (22%), mean age 65 years] were enrolled with a mean EF 27%, ischemic etiology in 54%, NYHA II 53% and III/IV 47%, and median NT‐proBNP 1971 pg/mL. HF therapies at baseline were among the most effectively employed in contemporary HF trials. GALACTIC‐HF randomized patients representative of recent HF registries and trials with substantial numbers of patients also having characteristics understudied in previous trials including more from North America (n = 1386), enrolled as inpatients (n = 2084), systolic blood pressure < 100 mmHg (n = 1127), estimated glomerular filtration rate < 30 mL/min/1.73 m2 (n = 528), and treated with sacubitril‐valsartan at baseline (n = 1594). Conclusions: GALACTIC‐HF enrolled a well‐treated, high‐risk population from both inpatient and outpatient settings, which will provide a definitive evaluation of the efficacy and safety of this novel therapy, as well as informing its potential future implementation

    Correlation between clinical severity and different non-invasive measurements of carbon monoxide concentration: A population study

    Full text link
    <div><p>Objectives</p><p>Carbon monoxide (CO) poisoning is a major concern in industrialized countries. Each year, thousands of victims, resulting in approximately 100 fatalities, are encountered in France. The diagnosis of CO poisoning is challenging; while carboxyhemoglobin (COHb) may be useful, it is a weak indicator of the severity of CO poisoning. This weak indicator may be a result of the delay between poisoning occurrence and the blood assay. Two apparatuses, CO oximeters and exhaled CO analyzers, now permit COHb to be determined outside hospitals. Our hypothesis is that these instruments allow the early measurement of COHb concentrations, which are more correlated with the severity of poisoning, expressed using the poisoning severity score (PSS).</p><p>Design</p><p>In an observational and retrospective cohort study, the distribution of COHb measurements obtained by CO oximetry or by exhaled CO analyzers was compared between groups of severity expressed using the PSS.</p><p>Setting</p><p>Data were collected in the Paris area from January 2006 to December 2010 by the French Surveillance System of CO poisoning.</p><p>Participants</p><p>All patients with CO poisoning reported to the French Surveillance System of CO poisoning.</p><p>Results</p><p>There was a significant difference in the COHb values obtained by CO oximetry between groups stratified according to PSS (p<0.0001). A significant difference in the values of exhaled CO was also observed between PSS groups (p = 0.006), although the relationship was not linear.</p><p>Conclusions</p><p>The COHb concentrations measured using CO oximetry, but not those measured using exhaled CO analyzers, were well correlated with the severity of CO poisoning.</p></div
    • 

    corecore