172 research outputs found

    Respiratory support by neurally adjusted ventilatory assist (NAVA) in severe RSV-related bronchiolitis: a case series report

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Neurally adjusted ventilatory assist (NAVA) is a new mode of mechanical ventilation controlled by diaphragmatic electrical signals. The electrical signals allow synchronization of ventilation to spontaneous breathing efforts of a child, as well as permitting pressure assistance proportional to the electrical signal. NAVA provides equally fine synchronization of respiratory support and pressure assistance varying with the needs of the child. NAVA has mainly been studied in children who underwent cardiac surgery during the period of weaning from a respirator.</p> <p>Case presentation</p> <p>We report here a series of 3 children (1 month, 3 years, and 28 days old) with severe respiratory distress due to RSV-related bronchiolitis requiring invasive mechanical ventilation with a high level of oxygen (FiO<sub>2 </sub>≥50%) for whom NAVA facilitated respiratory support. One of these children had diagnosis criteria for acute lung injury, another for acute respiratory distress syndrome.</p> <p>Establishment of NAVA provided synchronization of mechanical ventilatory support with the breathing efforts of the children. Respiratory rate and inspiratory pressure became extremely variable, varying at each cycle, while children were breathing easily and smoothly. All three children demonstrated less oxygen requirements after introducing NAVA (57 ± 6% to 42 ± 18%). This improvement was observed while peak airway pressure decreased (28 ± 3 to 15 ± 5 cm H<sub>2</sub>O). In one child, NAVA facilitated the management of acute respiratory distress syndrome with extensive subcutaneous emphysema.</p> <p>Conclusions</p> <p>Our findings highlight the feasibility and benefit of NAVA in children with severe RSV-related bronchiolitis. NAVA provides a less aggressive ventilation requiring lower inspiratory pressures with good results for oxygenation and more comfort for the children.</p

    Performances of domiciliary ventilators compared by using a parametric procedure

    Get PDF
    WOS:000379882100001International audienceBackground: Noninvasive mechanical ventilation is sufficiently widely used to motivate bench studies for evaluating and comparing performances of the domiciliary ventilators. In most (if not in all) of the previous studies, ventilators were tested in a single (or a very few) conditions, chosen to avoid asynchrony events. Such a practice does not reflect how the ventilator is able to answer the demand from a large cohort of patients with their inherent inter-patient variability. We thus developed a new procedure according which each ventilator was tested with more than 1200 "simulated" patients. Methods: Three lung mechanics (obstructive, restrictive and normal) were simulated using a mechanical lung (ASL 5000) driven by a realistic muscular pressure. 420 different dynamics for each of these three lung mechanics were considered by varying the breathing frequency and the mouth occlusion pressure. For each of the nine ventilators tested, five different parameter settings were investigated. The results are synthesized in colored maps where each color represents the ventilator (in) ability to synchronize with a given muscular pressure dynamics. A synchronizability e is then computed for each map. Results: The lung model, the breathing frequency and the mouth occlusion pressure strongly affect the synchronizability of ventilators. The Vivo 50 (Breas) and the SomnoVENT autoST (Weinmann) are well synchronized with the restrictive model ((epsilon) over bar = 86 and 78 %, respectively), whereas the Elisee 150 (ResMed), the BiPAP A40 and the Trilogy 100 (Philips Respironics) better fit with an obstructive lung mechanics ((epsilon) over bar = 87, 86 and 86 %, respectively). Triggering and pressurization performances of the nine ventilators present heterogeneities due to their different settings and operating strategies. Conclusion: Performances of domiciliary ventilators strongly depend not only on the breathing dynamics but also on the ventilator strategy. One given ventilator may be more adequate than another one for a given patient

    High tidal volume mechanical ventilation-induced lung injury in rats is greater after acid instillation than after sepsis-induced acute lung injury, but does not increase systemic inflammation: an experimental study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>To examine whether acute lung injury from direct and indirect origins differ in susceptibility to ventilator-induced lung injury (VILI) and resultant systemic inflammatory responses.</p> <p>Methods</p> <p>Rats were challenged by acid instillation or 24 h of sepsis induced by cecal ligation and puncture, followed by mechanical ventilation (MV) with either a low tidal volume (Vt) of 6 mL/kg and 5 cm H<sub>2</sub>O positive end-expiratory pressure (PEEP; LVt acid, LVt sepsis) or with a high Vt of 15 mL/kg and no PEEP (HVt acid, HVt sepsis). Rats sacrificed immediately after acid instillation and non-ventilated septic animals served as controls. Hemodynamic and respiratory variables were monitored. After 4 h, lung wet to dry (W/D) weight ratios, histological lung injury and plasma mediator concentrations were measured.</p> <p>Results</p> <p>Oxygenation and lung compliance decreased after acid instillation as compared to sepsis. Additionally, W/D weight ratios and histological lung injury scores increased after acid instillation as compared to sepsis. MV increased W/D weight ratio and lung injury score, however this effect was mainly attributable to HVt ventilation after acid instillation. Similarly, effects of HVt on oxygenation were only observed after acid instillation. HVt during sepsis did not further affect oxygenation, compliance, W/D weight ratio or lung injury score. Plasma interleukin-6 and tumour necrosis factor-α concentrations were increased after acid instillation as compared to sepsis, but plasma intercellular adhesion molecule-1 concentration increased during sepsis only. In contrast to lung injury parameters, no additional effects of HVt MV after acid instillation on plasma mediator concentrations were observed.</p> <p>Conclusions</p> <p>During MV more severe lung injury develops after acid instillation as compared to sepsis. HVt causes VILI after acid instillation, but not during sepsis. However, this differential effect was not observed in the systemic release of mediators.</p
    • …
    corecore