168 research outputs found
Wideband precision stabilization of the -18.6kV retarding voltage for the KATRIN spectrometer
The Karlsruhe Tritium Neutrino Experiment (KATRIN) measures the effective
electron anti-neutrino mass with an unprecedented design sensitivity of 0.2 eV
(90 % C.L.). In this experiment, the energy spectrum of beta electrons near the
tritium decay endpoint is analyzed with a highly accurate spectrometer. To
reach the KATRIN sensitivity target, the retarding voltage of this spectrometer
must be stable to the ppm level and well known on various time scales (
up to months), for values around -18.6 kV. A custom-designed high-voltage
regulation system mitigates the impact of interference sources in the absence
of a closed electric shield around the large spectrometer vessel. In this
article, we describe the regulation system and its integration into the KATRIN
setup. Independent monitoring methods demonstrate a stability within 2 ppm,
exceeding KATRIN's specifications.Comment: 28 pages, 17 figures, minor improvement
The KATRIN Pre-Spectrometer at reduced Filter Energy
The KArlsruhe TRItium Neutrino experiment, KATRIN, will determine the mass of
the electron neutrino with a sensitivity of 0.2 eV (90% C.L.) via a measurement
of the beta-spectrum of gaseous tritium near its endpoint of E_0 =18.57 keV. An
ultra-low background of about b = 10 mHz is among the requirements to reach
this sensitivity. In the KATRIN main beam-line two spectrometers of MAC-E
filter type are used in a tandem configuration. This setup, however, produces a
Penning trap which could lead to increased background. We have performed test
measurements showing that the filter energy of the pre-spectrometer can be
reduced by several keV in order to diminish this trap. These measurements were
analyzed with the help of a complex computer simulation, modeling multiple
electron reflections both from the detector and the photoelectric electron
source used in our test setup.Comment: 22 pages, 12 figure
Ultra-stable implanted 83Rb/83mKr electron sources for the energy scale monitoring in the KATRIN experiment
The KATRIN experiment aims at the direct model-independent determination of
the average electron neutrino mass via the measurement of the endpoint region
of the tritium beta decay spectrum. The electron spectrometer of the MAC-E
filter type is used, requiring very high stability of the electric filtering
potential. This work proves the feasibility of implanted 83Rb/83mKr calibration
electron sources which will be utilised in the additional monitor spectrometer
sharing the high voltage with the main spectrometer of KATRIN. The source
employs conversion electrons of 83mKr which is continuously generated by 83Rb.
The K-32 conversion line (kinetic energy of 17.8 keV, natural line width of 2.7
eV) is shown to fulfill the KATRIN requirement of the relative energy stability
of +/-1.6 ppm/month. The sources will serve as a standard tool for continuous
monitoring of KATRIN's energy scale stability with sub-ppm precision. They may
also be used in other applications where the precise conversion lines can be
separated from the low energy spectrum caused by the electron inelastic
scattering in the substrate.Comment: 30 pages, 10 figures, 1 table, minor revision of the preprint,
accepted by JINST on 5.2.201
Technical design and commissioning of the KATRIN large-volume air coil system
The KATRIN experiment is a next-generation direct neutrino mass experiment
with a sensitivity of 0.2 eV (90% C.L.) to the effective mass of the electron
neutrino. It measures the tritium -decay spectrum close to its endpoint
with a spectrometer based on the MAC-E filter technique. The -decay
electrons are guided by a magnetic field that operates in the mT range in the
central spectrometer volume; it is fine-tuned by a large-volume air coil system
surrounding the spectrometer vessel. The purpose of the system is to provide
optimal transmission properties for signal electrons and to achieve efficient
magnetic shielding against background. In this paper we describe the technical
design of the air coil system, including its mechanical and electrical
properties. We outline the importance of its versatile operation modes in
background investigation and suppression techniques. We compare magnetic field
measurements in the inner spectrometer volume during system commissioning with
corresponding simulations, which allows to verify the system's functionality in
fine-tuning the magnetic field configuration. This is of major importance for a
successful neutrino mass measurement at KATRIN.Comment: 32 pages, 16 figure
A pulsed, mono-energetic and angular-selective UV photo-electron source for the commissioning of the KATRIN experiment
The KATRIN experiment aims to determine the neutrino mass scale with a
sensitivity of 200 meV/c^2 (90% C.L.) by a precision measurement of the shape
of the tritium -spectrum in the endpoint region. The energy analysis of
the decay electrons is achieved by a MAC-E filter spectrometer. To determine
the transmission properties of the KATRIN main spectrometer, a mono-energetic
and angular-selective electron source has been developed. In preparation for
the second commissioning phase of the main spectrometer, a measurement phase
was carried out at the KATRIN monitor spectrometer where the device was
operated in a MAC-E filter setup for testing. The results of these measurements
are compared with simulations using the particle-tracking software
"Kassiopeia", which was developed in the KATRIN collaboration over recent
years.Comment: 19 pages, 16 figures, submitted to European Physical Journal
Influence of chromophores on quarternary structure of phycobiliproteins from the cyanobacterium, Mastigocladus laminosus
Chromophores of C-phycocyanin and phycoerythrο-cyanin have been chemically modified by reduction to
rubins , bleaching , photoisomerization , or perturbation
with bulky substituents. Pigments containing modified
chromophores, or hybrids containing modified and unmodified chromophores in individual protomers have been prepared. All modifications inhibit the association of the
(aß)-protomers of these pigments to higher aggregates. The
results demonstrate a pronounced effect of the state of
the chromophores on biliprotein quaternary structure. It
may be important in phycobi1isome assembly , and also in
the dual function of biliproteins as (i) antenna pigments
for photosynthesis and (ii) reaction centers for photomor-phogenesis
Results from the Project 8 phase-1 cyclotron radiation emission spectroscopy detector
The Project 8 collaboration seeks to measure the absolute neutrino mass scale
by means of precision spectroscopy of the beta decay of tritium. Our technique,
cyclotron radiation emission spectroscopy, measures the frequency of the
radiation emitted by electrons produced by decays in an ambient magnetic field.
Because the cyclotron frequency is inversely proportional to the electron's
Lorentz factor, this is also a measurement of the electron's energy. In order
to demonstrate the viability of this technique, we have assembled and
successfully operated a prototype system, which uses a rectangular waveguide to
collect the cyclotron radiation from internal conversion electrons emitted from
a gaseous Kr source. Here we present the main design aspects of the
first phase prototype, which was operated during parts of 2014 and 2015. We
will also discuss the procedures used to analyze these data, along with the
features which have been observed and the performance achieved to date.Comment: 3 pages; 2 figures; Proceedings of Neutrino 2016, XXVII International
Conference on Neutrino Physics and Astrophysics, 4-9 July 2016, London, U
Project 8 Phase III Design Concept
We present a working concept for Phase III of the Project 8 experiment,
aiming to achieve a neutrino mass sensitivity of ( C.L.)
using a large volume of molecular tritium and a phased antenna array. The
detection system is discussed in detail.Comment: 3 pages, 3 figures, Proceedings of Neutrino 2016, XXVII International
Conference on Neutrino Physics and Astrophysics, 4-9 July 2016, London, U
- …