136 research outputs found

    Use of crosslinkers to inactivate dentin MMPs

    Get PDF
    Objectives. This study evaluated the endogenous matrix metalloproteinase (MMP) activity of demineralized dentin matrix following 1 or 5 min pretreatment by various collagen crosslinkers. Generic MMP activity assay, total protein analysis, in situ zymography, gelatin zymography and multiplex bead technology were used to evaluate matrix-bound MMP activity. Methods. Six different crosslinkers; glutaraldehyde, riboflavin/UVA, riboflavin-5-monophospate/UVA, sumac berry extract, grape seed extract, and curcumin were used. Demineralized dentin beams were pretreated with respective crosslinkers for 1 or 5 min. Demineralized dentin beams with no crosslinker pretreatment served as control. The reduction in the total activity of dentin matrices were measured using generic MMP activity assay. Dentin slabs were used for in situ zymography and evaluated by using hydrolysis of self-quenched fluorescein-conjugated gelatin under confocal microscopy. Dentin beam extracts were used for total protein assay and multiplex analysis and powder extracts were used for gelatin zymography. Results. MMP activity in crosslinker pretreated samples decreased significantly between 21% and 70%, whereas untreated control samples' activity increased up to 84%. Zymograms confirmed a decrease in the gelatinolytic activity and in the amount of extractable total protein content. Multiplex analysis of extracts of crosslinker-treated dentin showed a reduction in the MMP-8, MMP-2 and MMP-9 release. Significance. The result of this work suggests that the effect of the crosslinkers is source dependent. The use of crosslinkers for as little as 1 min on demineralized dentin can inactivate the endogenous protease activity of dentin matrices. (C) 2015 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.Peer reviewe

    Repair bond strength of nanohybrid composite resins with a universal adhesive

    Get PDF
    Objective: To investigate the repair bond strength of fresh and aged nanohybrid and hybrid composite resins using a universal adhesive (UA).Materials and methods: Fresh and aged substrates were prepared using two nanohybrid (Venus Pearl, Heraus Kulzer; Filtek Supreme XTE, 3 M ESPE) and one hybrid (Z100, 3 M ESPE) composite resin, and randomly assigned to different surface treatments: (1) no treatment (control), (2) surface roughening with 320-grit (SR), (3) SR + UA (iBOND, Heraus Kulzer), (4) SR + Silane (Signum, Ceramic Bond I, Heraeus Kulzer) + UA, (5) SR + Sandblasting (CoJet, 3 M ESPE) + Silane + UA. After surface treatment, fresh composite resin was added to the substrates at 2 mm layer increments to a height of 5 mm, and light cured. Restored specimens were water-stored for 24 h and sectioned to obtain 1.0 × 1.0 mm beams (n = 12), and were either water-stored for 24 h at 37 °C, or water-stored for 24 h, and then thermocycled for 6000 cycles before microtensile bond strength (µTBS) testing. Data were analyzed with ANOVA and Tukey’s HSD tests (p = .05).Results: Combined treatment of SR, sandblasting, silane and UA provided repair bond strength values comparable to the cohesive strength of each tested resin material (p p Conclusions: Universal adhesive application is a reliable method for composite repair. Sandblasting and silane application slightly increases the repair strength for all substrate types.</p

    Effect of gallic acid addition on some mechanical properties of self-adhesive resin cements

    Get PDF
    Self-adhesive resin cements (RCs) activate matrix metalloproteinase (MMP) and cathepsin-related collagen degradation, and gallic acid (GA) inhibits the activity of both MMPs and cysteine cathepsins. The purpose of this study was to evaluate the setting time, biaxial flexural strength, and Vickers hardness of self-adhesive RCs after the addition of two different concentrations of GA. RelyX U200 (3M ESPE) and Panavia SA (Kuraray) were modified with 0.5 and 1 wt% GA. The setting time of five samples in each RC group was assessed using a thermocouple apparatus as described in the ISO 4049 test. Biaxial flexure strength was measured using a universal testing machine until failure. Vickers hardness was measured with three randomized indentations on the surface of each resin disc. RCs without GA were used as control. Data were analyzed using a one-way analysis of variance and Tukey’s HSD test (α = 0.05). The setting times ranged from 2.4 to 4.6 min for RelyX and from 4.9 to 6.0 min for Panavia. The biaxial flexure strength ranged from 76.5 to 109.7 MPa for RelyX and from 73.3 to 108.2 MPa for Panavia. Vickers hardness values ranged from 41.6 to 58.6 for RelyX and 27.2 to 33.6 for Panavia. The addition of 0.5 and 1 wt% GA to improve durability of resin-dentin bonds had no adverse effects on setting time, whereas the biaxial flexure strength and Vickers hardness values for the tested materials were significantly reduced.</p

    A novel dry-bonding approach to reduce collagen degradation and optimize resin-dentin interfaces

    Get PDF
    In dentistry, the wet-bonding approach relies on water to maintain demineralized collagen expanded for proper resin infiltration; nevertheless, hydrolytic instability of the resin-dentin interface is inevitable with current bonding techniques. Considering dimethyl sulfoxide’s (DMSO) ability to “biomodify” collagen and precipitate enzymes, the aim was to test whether the use of DMSO would permit adequate resin bonding to H3PO4-etched dehydrated dentin and assess its impact on collagen degradation by host-derived enzymes. Etched dentin surfaces from extracted sound human molars were randomly bonded in wet or dry conditions using aqueous or ethanolic DMSO solutions as pretreatments and bonding resins with or without DMSO. Bonded teeth were sectioned into resin-dentin slabs for confocal in situzymography and beams for microtensile bond strength test. Demineralized powdered dentin was incubated in the tested DMSO -media and a hydroxyproline assay evaluated dissolution of collagen peptides. Zymography was performed on protein extracts obtained from dry and wet H3PO4-ecthed dentin powder treated with the DMSO- media. The correlative biochemical analysis demonstrated that reduction of water content during dentin hybridization by the innovative dry-bonding approaches with DMSO is effective to inactivate host-derived MMP-2 and MMP-9 and thus reduce collagen degradation while simultaneously optimizing resin-dentin bonding.</p

    Effect of composite surface treatment and aging on the bond strength between a core build-up composite and a luting agent

    Get PDF
    Objective The purpose of this study was to assess the influence of conditioning methods and thermocycling on the bond strength between composite core and resin cement. Material and Methods Eighty blocks (8×8×4 mm) were prepared with core build-up composite. The cementation surface was roughened with 120-grit carbide paper and the blocks were thermocycled (5,000 cycles, between 5°C and 55°C, with a 30 s dwell time in each bath). A layer of temporary luting agent was applied. After 24 h, the layer was removed, and the blocks were divided into five groups, according to surface treatment: (NT) No treatment (control); (SP) Grinding with 120-grit carbide paper; (AC) Etching with 37% phosphoric acid; (SC) Sandblasting with 30 mm SiO2 particles, silane application; (AO) Sandblasting with 50 mm Al2O3 particles, silane application. Two composite blocks were cemented to each other (n=8) and sectioned into sticks. Half of the specimens from each block were immediately tested for microtensile bond strength (µTBS), while the other half was subjected to storage for 6 months, thermocycling (12,000 cycles, between 5°C and 55°C, with a dwell time of 30 s in each bath) and µTBS test in a mechanical testing machine. Bond strength data were analyzed by repeated measures two-way ANOVA and Tukey test (α=0.05). Results The µTBS was significantly affected by surface treatment (p=0.007) and thermocycling (p=0.000). Before aging, the SP group presented higher bond strength when compared to NT and AC groups, whereas all the other groups were statistically similar. After aging, all the groups were statistically similar. SP submitted to thermocycling showed lower bond strength than SP without thermocycling. Conclusion Core composites should be roughened with a diamond bur before the luting process. Thermocycling tends to reduce the bond strength between composite and resin cement

    Correlation between clinical performance and degree of conversion of resin cements: a literature review

    Get PDF
    AbstractResin-based cements have been frequently employed in clinical practice to lute indirect restorations. However, there are numerous factors that may compromise the clinical performance of those cements. The aim of this literature review is to present and discuss some of the clinical factors that may affect the performance of current resin-based luting systems. Resin cements may have three different curing mechanisms: chemical curing, photo curing or a combination of both. Chemically cured systems are recommended to be used under opaque or thick restorations, due to the reduced access of the light. Photo-cured cements are mainly indicated for translucent veneers, due to the possibility of light transmission through the restoration. Dual-cured are more versatile systems and, theoretically, can be used in either situation, since the presence of both curing mechanisms might guarantee a high degree of conversion (DC) under every condition. However, it has been demonstrated that clinical procedures and characteristics of the materials may have many different implications in the DC of currently available resin cements, affecting their mechanical properties, bond strength to the substrate and the esthetic results of the restoration. Factors such as curing mechanism, choice of adhesive system, indirect restorative material and light-curing device may affect the degree of conversion of the cement and, therefore, have an effect on the clinical performance of resin-based cements. Specific measures are to be taken to ensure a higher DC of the luting system to be used

    Hyperzincemia from ingestion of denture adhesives

    No full text
    • …
    corecore