    Implementation of Range Autofocus for SAR Radar Imaging

    Get PDF
    The range calculation for an FMCW radar depends on accurate linear modulation. In some circumstances, linear modulation may not be available and must be corrected for. This paper describes an autofocus technique used to correct for phase error due to non-linearities in the components of a FMCW radar. Also described here is the algorithm used in calculating the phase error and application of the phase correction with triangle modulation. Known errors were calculated at certain distances and applied to correcting the phase of data taken at similar distances. The results given were generated using a SAR working outside linear ranges

    Data Logging System for a Synthetic Aperture Radar Unit

    Get PDF
    A small, existing radar unit lacked the ability to automatically store the data it was receiving, which made its use clunky and cumbersome. A system was constructed to allow an on-board microprocessor to track distance traveled, and automatically store the data output from the radar unit to a portable memory unit for later data processing. Distance traveled is determined using a specially designed mobile cart, which electronically converts the rotation of a wheel into an electrical signal while also providing stability for taking accurate radar measurements. The output data from the radar unit is stored as a properly-formatted sound file to allow for immediate data analysis