13 research outputs found

    Use of the impulse oscillometry system for testing pulmonary function during methacholine bronchoprovocation in horses.

    Full text link
    OBJECTIVE: To compare sensitivity of the impulse oscillometry system (IOS) with that of the conventional reference technique (CRT; ie, esophageal balloon method) for pulmonary function testing in horses. ANIMALS: 10 horses (4 healthy; 6 with recurrent airway obstruction [heaves] in remission). PROCEDURE: Healthy horses (group-A horses) and heaves-affected horses (group-B horses) were housed in a controlled environment. At each step of a methacholine bronchoprovocation test, threshold concentration (TC(2SD); results in a 2-fold increase in SD of a value) and sensitivity index (SI) were determined for respiratory tract system resistance (R(rs)) and respiratory tract system reactance (X(rs)) at 5 to 20 Hz by use of IOS and for total pulmonary resistance (RL) and dynamic lung compliance (C(dyn)), by use of CRT. RESULTS: Bronchoconstriction resulted in an increase in R(rs) at 5 Hz (R(5Hz)) and a decrease in X(rs) at all frequencies. Most sensitive parameters were X(rs) at 5 Hz (X(5Hz)), R(5Hz), and R(5Hz):R(10Hz) ratio; RL and the provocation concentration of methacholine resulting in a 35% decrease in dynamic compliance (PC(35)C(dyn)) were significantly less sensitive than these IOS parameters. The TC(2SD) for X(rs) at 5 and 10 Hz was significantly lower in group-B horses, compared with group-A horses. The lowest TC(2SD) was obtained for X(5Hz) in group-B horses and R(5Hz) in group-A horses. CONCLUSIONS AND CLINICAL RELEVANCE: In contrast to CRT parameters, IOS parameters were significantly more sensitive for testing pulmonary function.The IOS provides a practical and noninvasive pulmonary function test that may be useful in assessing subclinical changes in horses
    corecore