64 research outputs found

    Pericardiectomy for constrictive pericarditis: a risk factor analysis for early and late failure

    Get PDF
    Predictors of early and late failure of pericardiectomy for constrictive pericarditis (CP) have not been established. Early and late outcomes of a cumulative series of 81 (mean age 60\ua0years; mean EuroSCORE II, 3.3%) consecutive patients from three European cardiac surgery centers were reviewed. Predictors of a combined endpoint comprising in-hospital death or major complications (including multiple transfusion) were identified with binary logistic regression. Non-parametric estimates of survival were obtained with the Kaplan\u2013Meier method. Predictors of poor late outcomes were established using Cox proportional hazard regression. There were 4 (4.9%) in-hospital deaths. Preoperative central venous pressure > 15\ua0mmHg (p = 0.005) and the use of cardiopulmonary bypass (p = 0.016) were independent predictors of complicated in-hospital course, which occurred in 29 (35.8%) patients. During follow-up (median, 5.4\ua0years), preoperative renal impairment was a predictor of all-cause death (p = 0.0041), cardiac death (p = 0.0008), as well as hospital readmission due to congestive heart failure (p = 0.0037); while partial pericardiectomy predicted all-cause death (p = 0.028) and concomitant cardiac operation predicted cardiac death (p = 0.026), postoperative central venous pressure < 10\ua0mmHg was associated with a low risk both of all-cause and cardiac death (p < 0.0001 for both). Ten-year adjusted survival free of all-cause death, cardiac death, and hospital readmission were 76.9%, 94.7%, and 90.6%, respectively. In high-risk patients with CP, performing pericardiectomy before severe constriction develops and avoiding cardiopulmonary bypass (when possible) could contribute to improving immediate outcomes post-surgery. Complete removal of cardiac constriction could enhance long-term outcomes

    Prosthesis-patient mismatch after aortic valve replacement in the PARTNER 2 trial and registry

    Get PDF
    Objectives This study aimed to compare incidence and impact of measured prosthesis-patient mismatch (PPMM) versus predicted PPM (PPMP) after surgical aortic valve replacement (SAVR) and transcatheter aortic valve replacement (TAVR). Background TAVR studies have used measured effective orifice area indexed (EOAi) to body surface area (BSA) to define PPM, but most SAVR series have used predicted EOAi. This difference may contribute to discrepancies in incidence and outcomes of PPM between series. Methods The study analyzed SAVR patients from the PARTNER (Placement of Aortic Transcatheter Valves) 2A trial and TAVR patients from the PARTNER 2 SAPIEN 3 Intermediate Risk registry. PPM was classified as moderate if EOAi ≤0.85 cm2/m2 (≤0.70 if obese: body mass index ≥30 kg/m2) and severe if EOAi ≤0.65 cm2/m2 (≤0.55 if obese). PPMM was determined by the core lab–measured EOAi on 30-day echocardiogram. PPMP was determined by 2 methods: 1) using normal EOA reference values previously reported for each valve model and size (PPMP1; n = 929 SAVR, 1,069 TAVR) indexed to BSA; and 2) using normal reference EOA predicted from aortic annulus size measured by computed tomography (PPMP2; n = 864 TAVR only) indexed to BSA. Primary endpoint was the composite of 5-year all-cause death and rehospitalization. Results The incidence of moderate and severe PPMP was much lower than PPMM in both SAVR (PPMP1: 28.4% and 1.2% vs. PPMM: 31.0% and 23.6%) and TAVR (PPMP1: 21.0% and 0.1% and PPMP2: 17.0% and 0% vs. PPMM: 27.9% and 5.7%). The incidence of severe PPMM and severe PPMP1 was lower in TAVR versus SAVR (P < 0.001). The presence of PPM by any method was associated with higher transprosthetic gradient. Severe PPMP1 was independently associated with events in SAVR after adjustment for sex and Society of Thoracic Surgeons score (hazard ratio: 3.18;95% CI: 1.69-5.96; P < 0.001), whereas no association was observed between PPM by any method and outcomes in TAVR. Conclusions EOAi measured by echocardiography results in a higher incidence of PPM following SAVR or TAVR than PPM based on predicted EOAi. Severe PPMP is rare (<1.5%), but is associated with increased all-cause death and rehospitalization after SAVR, whereas it is absent following TAVR

    Standardized Definitions for Bioprosthetic Valve Dysfunction Following Aortic or Mitral Valve Replacement: JACC State-of-the-Art Review.

    Full text link
    peer reviewedBioprosthetic valve dysfunction (BVD) and bioprosthetic valve failure (BVF) may be caused by structural or nonstructural valve dysfunction. Both surgical and transcatheter bioprosthetic valves have limited durability because of structural valve deterioration. The main objective of this summary of experts participating in a virtual workshop was to propose standardized definitions for nonstructural and structural BVD and BVF following aortic or mitral biological valve replacement with the goal of facilitating research reporting and implementation of these terms in clinical practice. Definitions of structural BVF, based on valve reintervention or death, underestimate the true incidence of BVF. However, definitions solely based on the presence of high transprosthetic gradient at a given echocardiogram during follow-up overestimate the incidence of structural BVD and BVF. Definitions of aortic or mitral structural BVD must therefore include the confirmation by imaging of permanent structural changes to the leaflets alongside evidence of deterioration in valve hemodynamic function at echocardiography follow-up
    • …
    corecore