274 research outputs found

    Ultrasound in Rheumatology

    Get PDF
    __Abstract__ Ultrasonography is an imaging modality that is used increasingly in daily practice for the investigation and management of rheumatoid arthritis (RA). This introduction provides an overview on the rationale for using US in RA by discussing relevant events and developments in the history of RA. This is followed by a short section on the history of medical US. Subsequently, the section on the technique of US will describe relevant concepts of US for this thesis. This general introduction closes with the outline of the thesis and the aims

    Modal Languages for Topology: Expressivity and Definability

    Get PDF
    In this paper we study the expressive power and definability for (extended) modal languages interpreted on topological spaces. We provide topological analogues of the van Benthem characterization theorem and the Goldblatt-Thomason definability theorem in terms of the well established first-order topological language LtL_t

    Performance of a cognitive load inventory during simulated handoffs: Evidence for validity.

    Get PDF
    BackgroundAdvancing patient safety during handoffs remains a public health priority. The application of cognitive load theory offers promise, but is currently limited by the inability to measure cognitive load types.ObjectiveTo develop and collect validity evidence for a revised self-report inventory that measures cognitive load types during a handoff.MethodsBased on prior published work, input from experts in cognitive load theory and handoffs, and a think-aloud exercise with residents, a revised Cognitive Load Inventory for Handoffs was developed. The Cognitive Load Inventory for Handoffs has items for intrinsic, extraneous, and germane load. Students who were second- and sixth-year students recruited from a Dutch medical school participated in four simulated handoffs (two simple and two complex cases). At the end of each handoff, study participants completed the Cognitive Load Inventory for Handoffs, Paas' Cognitive Load Scale, and one global rating item for intrinsic load, extraneous load, and germane load, respectively. Factor and correlational analyses were performed to collect evidence for validity.ResultsConfirmatory factor analysis yielded a single factor that combined intrinsic and germane loads. The extraneous load items performed poorly and were removed from the model. The score from the combined intrinsic and germane load items associated, as predicted by cognitive load theory, with a commonly used measure of overall cognitive load (Pearson's r = 0.83, p < 0.001), case complexity (beta = 0.74, p < 0.001), level of experience (beta = -0.96, p < 0.001), and handoff accuracy (r = -0.34, p < 0.001).ConclusionThese results offer encouragement that intrinsic load during handoffs may be measured via a self-report measure. Additional work is required to develop an adequate measure of extraneous load

    Medical Residents’ Informal Learning from Pharmacists in the Clinical Workplace

    Get PDF
    UNLABELLED: Workplace-based interactions between residents and pharmacists, though relatively underexplored, might contribute substantially to learning. This international study sought to investigate the affordances residents use for informal learning about medications, their interactions with pharmacists and patterns of resident-pharmacist engagement, as well as residents' perceived impact of these interactions on their learning. Contextual differences between US and Dutch residency training and electronic health record (EHR) may impact informal learning about medications. We conducted a cross-sectional, online, 25-item survey study, including closed-format and open-response questions among current resident physicians (post-graduate years 1-6, from a variety of residency programs n  = 803) from the University of California San Francisco, the University of Minnesota, and the University Medical Center Utrecht. Responses from 173 residents in both countries revealed that these physician trainees were afforded opportunities to engage in a wide variety of pharmacotherapy-related activities but engaged differently with social and environmental resources for support. Residents from the United States (US) utilized pharmacists and Up-To-Date, whereas Dutch residents preferentially utilized the online Dutch medication information site and EHR-embedded medication resources. US residents interacted with pharmacists significantly more frequently than Dutch residents. Pharmacists provided residents with a wide range of useful information, much of which is integrated into the medication resources in the Dutch EHR-based decision-support system. While US residents reported overwhelmingly that informal interactions with pharmacists contribute to their learning about medications, Dutch residents' responses did not confirm this. Intentionally designing residents' training to include opportunities for interactions with pharmacists could potentially positively impact residents' informal workplace learning. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s40670-023-01784-1

    The logic behind entrustable professional activity frameworks: A scoping review of the literature

    Get PDF
    Introduction: Entrustable professional activities (EPAs), discrete profession-specific tasks requiring integration of multiple competencies, are increasingly used to help define and inform curricula of specialty training programmes. Although guidelines exist to help guide the developmental process, deciding what logic to use to draft a preliminary EPA framework poses a crucial but often difficult first step. The logic of an EPA framework can be defined as the perspective used by its developers to break down the practice of a profession into units of professional work. This study aimed to map dominant logics and their rationales across postgraduate medical education and fellowship programmes. Methods: A scoping review using systematic searches within five electronic databases (Medline, Embase, Google Scholar, Scopus and Web of Science) was performed. Dominant logics of included papers were identified using inductive coding and iterative analysis. Results: In total, 42 studies were included. Most studies were conducted in the United States (n = 22; 52%), Canada (n = 6; 14%) and the Netherlands (n = 4; 10%). Across the reported range of specialties, family medicine (n = 4; 10%), internal medicine (n = 4; 10%), paediatrics (n = 3; 7%) and psychiatry (n = 3; 7%) were the most common. Three dominant logics could be identified, namely, ‘service provision’, ‘procedures’ and/or ‘disease or patient categories’. The majority of papers (n = 37; 88%) used two or more logics when developing EPA frameworks (median = 3, range = 1–4). Disease or patient groups and service provision were the most common logics used (39% and 37%, respectively). Conclusions: Most programmes used a combination of logics when trying to capture the essential tasks of a profession in EPAs. For each of the three dominant logics, the authors arrived at a definition and identified benefits, limitations and examples. These findings may potentially inform best practice guidelines for EPA development

    Assessment of disease activity in patients with rheumatoid arthritis using optical spectral transmission measurements, a non-invasive imaging technique

    Get PDF
    Objectives: In rheumatoid arthritis (RA), treat-to-target strategies require instruments for valid detection of joint inflammation. Therefore, imaging modalities are increasingly used in clinical practice. Optical spectral transmission (OST) measurements are non-invasive and fast and may therefore have benefits over existing imaging modalities. We tested whether OST could measure disease activity validly in patients with RA. Methods: In 59 patients with RA and 10 patients with arthralgia, OST, joint counts, Disease Activity Score (DAS) 28 and ultrasonography (US) were performed. Additionally, MRI was performed in patients with DAS28<2.6. We developed and validated within the same cohort an algorithm for detection of joint inflammation by OST with US as reference. Results: At the joint level, OST and US performed similarly inproximal interphalangeal-joints (area under the receiver-operating curve (AUC) of 0.79, p<0.0001) andmetacarpophalangeal joints (AUC 0.78, p<0.0001). Performance was less similar in wrists (AUC 0.62, p=0.006). On the patient level, OST correlated moderately with clinical examination (DAS28 r=0.42, p=0.001), and US scores (r=0.64, p<0.0001). Furthermore, in patients with subclinical and low disease activity, there was a correlation between OST and MRI synovitis score (RAMRIS (Rheumatoid Arthritis MRI Scoring) synovitis), r=0.52, p=0.005. Conclusions: In this pilot study, OST performed moderately in the detection of joint inflammation in patients with RA. Further studies are needed to determine the diagnostic performance in a new cohort of patients with RA

    Exploring the institutional logics of health professions education scholarship units

    Get PDF
    Peer Reviewedhttps://deepblue.lib.umich.edu/bitstream/2027.42/137533/1/medu13334.pdfhttps://deepblue.lib.umich.edu/bitstream/2027.42/137533/2/medu13334_am.pd

    Very different performance of the power Doppler modalities of several ultrasound machines ascertained by a microvessel flow phantom

    Get PDF
    Introduction: In many patients with rheumatoid arthritis (RA) subclinical disease activity can be detected with ultrasound (US), especially using power Doppler US (PDUS). However, PDUS may be highly dependent on the type of machine. This could create problems both in clinical trials and in daily clinical practice. To clarify how the PDUS signal differs between machines we created a microvessel flow phantom.Methods: The flow phantom contained three microvessels (150, 1000, 2000 microns). A syringe pump was used to generate flows. Five US machines were used. Settings were optimised to assess the lowest detectable flow for each US machine.Results: The minimal detectable flow velocities showed very large differences between the machines. Only two of the machines may be able to detect the very low flows in the capillaries of inflamed joints. There was no clear relation with price. One of the lower-end machines actually performed best in all three vessel sizes.Conclusions: We created a flow phantom to test the sensitivity of US machines to very low flows in small vessels. The sensitivity of the power Doppler modalities of 5 different machines was very different. The differences found between the machines are probably caused by fundamental differences in processing of the PD signal or internal settings inaccessible to users. Machines considered for PDUS assessment of RA patients should be tested using a flow phantom similar to ours. Within studies, only a single machine type should be used
    corecore