    Preventing complicated transseptal puncture with intracardiac echocardiography: case report

    Get PDF
    BACKGROUND: Recently, intracardiac echocardiography emerged as a useful tool in the electrophysiology laboratories for guiding transseptal left heart catheterizations, for avoiding thromboembolic and mechanical complications and assessing the ablation lesions characteristics. Although the value of ICE is well known, it is not a universal tool for achieving uncomplicated access to the left atrium. We present a case in which ICE led to interruption of a transseptal procedure because several risk factors for mechanical complications were revealed. CASE PRESENTATION: A case of a patient with paroxysmal atrial fibrillation and atrial flutter, and distorted intracardiac anatomy is presented. Intracardiac echocardiography showed a small oval fossa abouting to an enlarged aorta anteriorly. A very small distance from the interatrial septum to the left atrial free wall was seen. The latter two conditions were predisposing to a complicated transseptal puncture. According to fluoroscopy the transseptal needle had a correct position, but the intracardiac echo image showed that it was actually pointing towards the aortic root and most importantly, that it was virtually impossible to stabilize it in the fossa itself. Based on intracardiac echo findings a decision was made to limit the procedure only to ablation of the cavotricuspid isthmus and not to proceed further so as to avoid complications. CONCLUSION: This case report illustrates the usefulness of the intracardiac echocardiography in preventing serious or even fatal complications in transseptal procedures when the cardiac anatomy is unusual or distorted. It also helps to understand the possible mechanisms of mechanical complications in cases where fluoroscopic images are apparently normal

    Mid-term echocardiographic follow up of left ventricular function with permanent right ventricular pacing in pediatric patients with and without structural heart disease

    Get PDF
    BACKGROUND: Chronic right ventricular apical pacing may have detrimental effect on left ventricular function and may promote to heart failure in adult patients with left ventricular dysfunction. METHODS: A group of 99 pediatric patients with previously implanted pacemaker was studied retrospectively. Forty-three patients (21 males) had isolated congenital complete or advanced atrioventricular block. The remaining 56 patients (34 males) had pacing indication in the presence of structural heart disease. Thirty-two of them (21 males) had isolated structural heart disease and the remaining 24 (13 males) had complex congenital heart disease. Patients were followed up for an average of 53 ± 41.4 months with 12-lead electrocardiogram and transthoracic echocardiography. Left ventricular shortening fraction was used as a marker of ventricular function. QRS duration was assessed using leads V(5 )or II on standard 12-lead electrocardiogram. RESULTS: Left ventricular shortening fraction did not change significantly after pacemaker implantation compared to preimplant values overall and in subgroups. In patients with complex congenital heart malformations shortening fraction decreased significantly during the follow up period. (0.45 ± 0.07 vs 0.35 ± 0.06, p = 0.015). The correlation between the change in left ventricular shortening fraction and the mean increase of paced QRS duration was not significant. Six patients developed dilated cardiomyopathy, which was diagnosed 2 months to 9 years after pacemaker implantation. CONCLUSION: Chronic right ventricular pacing in pediatric patients with or without structural heart disease does not necessarily result in decline of left ventricular function. In patients with complex congenital heart malformations left ventricular shortening fraction shows significant decrease
    corecore