1,069 research outputs found

    Peace Education Practices in Pre-Service Teacher Training Programs: and Analysis

    Get PDF
    This study was designed to investigate peace education in pre-service teacher training programs in Khyber Pakhtunkhwa, Pakistan. The objectives of the present study to find out :( a) to examine prevailing practices of peace education in pre-service teacher training programs in Khyber Pakhtunkhwa Pakistan. (b) To evaluate the views of teacher Educators regarding the need of peace education in pre-service teacher training programs in Khyber Pakhtunkhwa Pakistan. (c) To suggest way of integrating peace education in pre-service teacher training programs in Khyber Pakhtunkhwa Pakistan. Using Survey method the data were collected through questionnaire from 245 teachers using simple random technique. A questionnaire was developed to investigate the opinions of the participants of the study. The data was analyzed by using the mean score, frequency and percentage

    Knowledge Management practices: Teachers perception

    Get PDF
    In today’s world, Knowledge Management is considered as a key to organizational growth and competitiveness. This study aim was to investigate the perception of teachers about main factors affecting the teaching learning process in adopting and applying Knowledge Management. The main objectives of the study were (i) to explore the existing Knowledge Management Practices of teachers in International Islamic University Islamabad (ii) to find out the difficulties regarding knowledge management and (iii) to examine the factors affecting the application of Knowledge Management Practices in improving the performance of teachers. Qualitative method was used as mode of inquiry. Data was collected through an Interview guide. Concurrent exploratory design was used in the study while collecting and analyzing data. Qualitative data was analyzed through content analysis and percentage

    Orientation Independent Chipless RFID Tag Using Novel Trefoil Resonators

    Get PDF
    In this paper, a compact and fully passive bit encoding circuit, capable of operating as a chipless radio frequency identification (RFID) tag is presented. The structure consists of novel concentric trefoil-shaped slot resonators realized using Rogers RT/duroid (R) 5880 laminate, occupying a physical footprint of 13.55 x 13.55 mm(2). Each resonating element is associated with a particular data bit, having a 1:1 resonator-to-bit correspondence. Bit sequences are configured through introducing modifications in the geometric structure either by addition or exclusion of each nested slot resonator. Such changes manifest directly in the electromagnetic signature of the tag as presence or absence of corresponding resonant peaks. The proposed 10-bit tag offers minimized inter-resonator mutual coupling and insensitivity to changes in polarization and incident angles thereby demonstrating orientation independent functionality. Moreover, error-free encoding is achieved through stabilizing the shift in resonant frequencies for a variety of different geometric configurations and orientation of the structure. The tag operates within the license-free ultrawideband ranging from 5.4 to 10.4 GHz, providing spectral bit capacity and bit density of 2 bits/GHz and 5.44 bits/cm(2) respectively

    Orientation independent chipless RFID tag using novel trefoil resonators

    Get PDF
    In this paper, a compact and fully passive bit encoding circuit, capable of operating as a chipless radio frequency identification (RFID) tag is presented. The structure consists of novel concentric trefoil-shaped slot resonators realized using Rogers RT/duroid 5880 laminate, occupying a physical footprint of 13.55 ×\times 13.55 mm^2. Each resonating element is associated with a particular data bit, having a 1:1 resonator-to-bit correspondence. Bit sequences are configured through introducing modifications in the geometric structure either by addition or exclusion of each nested slot resonator. Such changes manifest directly in the electromagnetic signature of the tag as presence or absence of corresponding resonant peaks. The proposed 10-bit tag offers minimized inter-resonator mutual coupling and insensitivity to changes in polarization and incident angles thereby demonstrating orientation independent functionality. Moreover, error-free encoding is achieved through stabilizing the shift in resonant frequencies for a variety of different geometric configurations and orientation of the structure. The tag operates within the license-free ultra-wideband ranging from 5.4 to 10.4 GHz, providing spectral bit capacity and bit density of 2 bits/GHz and 5.44 bits/cm^2 respectively

    A mutation in the major autophagy gene, WIPI2, associated with global developmental abnormalities

    Get PDF
    We describe a large consanguineous pedigree from a remote area of Northern Pakistan, with a complex developmental disorder associated with wide-ranging symptoms, including mental retardation, speech and language impairment and other neurological, psychiatric, skeletal and cardiac abnormalities. We initially carried out a genetic study using the HumanCytoSNP-12 v2.1 Illumina gene chip on nine family members and identified a single region of homozygosity shared amongst four affected individuals on chromosome 7p22 (positions 3059377–5478971). We performed whole-exome sequencing on two affected individuals from two separate branches of the extended pedigree and identified a novel nonsynonymous homozygous mutation in exon 9 of the WIPI2 (WD-repeat protein interacting with phosphoinositide 2) gene at position 5265458 (c.G745A;pV249M). WIPI2 plays a critical role in autophagy, an evolutionary conserved cellular pathway implicated in a growing number of medical conditions. The mutation is situated in a highly conserved and critically important region of WIPI2, responsible for binding PI(3)P and PI(3,5)P2, an essential requirement for autophagy to proceed. The mutation is absent in all public databases, is predicted to be damaging and segregates with the disease phenotype. We performed functional studies in vitro to determine the potential effects of the mutation on downstream pathways leading to autophagosome assembly. Binding of the V231M mutant of WIPI2b to ATG16L1 (as well as ATG5–12) is significantly reduced in GFP pull-down experiments, and fibroblasts derived from the patients show reduced WIPI2 puncta, reduced LC3 lipidation and reduced autophagic flux

    Detector Description and Performance for the First Coincidence Observations between LIGO and GEO

    Get PDF
    For 17 days in August and September 2002, the LIGO and GEO interferometer gravitational wave detectors were operated in coincidence to produce their first data for scientific analysis. Although the detectors were still far from their design sensitivity levels, the data can be used to place better upper limits on the flux of gravitational waves incident on the earth than previous direct measurements. This paper describes the instruments and the data in some detail, as a companion to analysis papers based on the first data.Comment: 41 pages, 9 figures 17 Sept 03: author list amended, minor editorial change

    Upper limits on the strength of periodic gravitational waves from PSR J1939+2134

    Get PDF
    The first science run of the LIGO and GEO gravitational wave detectors presented the opportunity to test methods of searching for gravitational waves from known pulsars. Here we present new direct upper limits on the strength of waves from the pulsar PSR J1939+2134 using two independent analysis methods, one in the frequency domain using frequentist statistics and one in the time domain using Bayesian inference. Both methods show that the strain amplitude at Earth from this pulsar is less than a few times 102210^{-22}.Comment: 7 pages, 1 figure, to appear in the Proceedings of the 5th Edoardo Amaldi Conference on Gravitational Waves, Tirrenia, Pisa, Italy, 6-11 July 200

    Search for Gravitational Waves from Primordial Black Hole Binary Coalescences in the Galactic Halo

    Get PDF
    We use data from the second science run of the LIGO gravitational-wave detectors to search for the gravitational waves from primordial black hole (PBH) binary coalescence with component masses in the range 0.2--1.0M1.0 M_\odot. The analysis requires a signal to be found in the data from both LIGO observatories, according to a set of coincidence criteria. No inspiral signals were found. Assuming a spherical halo with core radius 5 kpc extending to 50 kpc containing non-spinning black holes with masses in the range 0.2--1.0M1.0 M_\odot, we place an observational upper limit on the rate of PBH coalescence of 63 per year per Milky Way halo (MWH) with 90% confidence.Comment: 7 pages, 4 figures, to be submitted to Phys. Rev.

    Improving the sensitivity to gravitational-wave sources by modifying the input-output optics of advanced interferometers

    Get PDF
    We study frequency dependent (FD) input-output schemes for signal-recycling interferometers, the baseline design of Advanced LIGO and the current configuration of GEO 600. Complementary to a recent proposal by Harms et al. to use FD input squeezing and ordinary homodyne detection, we explore a scheme which uses ordinary squeezed vacuum, but FD readout. Both schemes, which are sub-optimal among all possible input-output schemes, provide a global noise suppression by the power squeeze factor, while being realizable by using detuned Fabry-Perot cavities as input/output filters. At high frequencies, the two schemes are shown to be equivalent, while at low frequencies our scheme gives better performance than that of Harms et al., and is nearly fully optimal. We then study the sensitivity improvement achievable by these schemes in Advanced LIGO era (with 30-m filter cavities and current estimates of filter-mirror losses and thermal noise), for neutron star binary inspirals, and for narrowband GW sources such as low-mass X-ray binaries and known radio pulsars. Optical losses are shown to be a major obstacle for the actual implementation of these techniques in Advanced LIGO. On time scales of third-generation interferometers, like EURO/LIGO-III (~2012), with kilometer-scale filter cavities, a signal-recycling interferometer with the FD readout scheme explored in this paper can have performances comparable to existing proposals. [abridged]Comment: Figs. 9 and 12 corrected; Appendix added for narrowband data analysi
    corecore