203 research outputs found

    Major Complex Abdominal Wall Repair in Contaminated Fields with Use of a Non-cross-linked Biologic Mesh: A Dual-Institutional Experience

    Get PDF
    Background Data on the use of biologic mesh in abdominal wall repair in complex cases remain sparse. Aim of this study was to evaluate a non-cross-linked porcine acellular dermal matrix for repair of complex contaminated abdominal wall defects. Methods Retrospective observational cohort study of consecutive patients undergoing abdominal wall repair with use of Strattice™ Reconstructive Tissue Matrix (LifeCell Corporation, Oxford, UK) between January 2011 and February 2015 at two National Intestinal Failure Units. Results Eighty patients were identified. Indications for abdominal wall repair included enterocutaneous fistula takedown (n = 50), infected synthetic mesh removal (n = 9), restoration of continuity or creation of a stoma with concomitant ventral hernia repair (n = 12), and others (n = 9). The median defect area was 143.0 cm2 (interquartile range or IQR 70.0–256.0 cm2). All had a grade III or IV hernia. Component separation technique (CST) was performed in 54 patients (68%). Complete fascial closure was not possible despite CST and biologic mesh-assisted traction (bridged repair) in 20 patients (25%). In-hospital mortality was 1%. Thirty-six patients (45%) developed a wound infection. None required mesh removal. Of 76 patients with a median clinical follow-up of 7 months (IQR 4–15) available for analysis, 10 patients (13%) developed a hernia recurrence, of whom 3 had undergone bridged repairs. Seven patients developed a postoperative (recurrent) fistula (9%). Conclusion Repair of challenging and contaminated abdominal wall defects can be done effectively with non-cross-linked biologic mesh and component separation technique without the need for mesh removal despite wound infections

    Impact of non-axillary sentinel node biopsy on staging and treatment of breast cancer patients

    Get PDF
    The purpose of this study was to evaluate the occurrence of lymphatic drainage to non-axillary sentinel nodes and to determine the implications of this phenomenon. A total of 549 breast cancer patients underwent lymphoscintigraphy after intratumoural injection of 99mTc-nanocolloid. The sentinel node was intraoperatively identified with the aid of intratumoural administered patent blue dye and a gamma-ray detection probe. Histopathological examination of sentinel nodes included step-sectioning at six levels and immunohistochemical staining. A sentinel node outside level I or II of the axilla was found in 149 patients (27%): internal mammary sentinel nodes in 86 patients, other non-axillary sentinel nodes in 44 and both internal mammary and other non-axillary sentinel nodes in nineteen patients. The intra-operative identification rate was 80%. Internal mammary metastases were found in seventeen patients and metastases in other non-axillary sentinel nodes in ten patients. Staging improved in 13% of patients with non-axillary sentinel lymph nodes and their treatment strategy was changed in 17%. A small proportion of clinically node negative breast cancer patients can be staged more precisely by biopsy of sentinel nodes outside level I and II of the axilla, resulting in additional decision criteria for postoperative regional or systemic therapy

    Will early detection of non-axillary sentinel nodes affect treatment decisions?

    Get PDF
    Axillary lymph node involvement is the best prognostic factor for breast cancer survival. Staging breast cancers by axillary dissection remains standard management and is part of the UK national guidelines for breast cancer treatment. In the presence of involved axillary lymph nodes best treatment has been shown to be axillary clearance (Fentiman and Mansell, 1991), but clearly for women whose nodes are uninvolved avoidance of morbidity is optimal and this will be achieved by minimal dissection of the axilla. Thus, for node-negative women the introduction of the sentinel node biopsy technique may revolutionise the approach to the axilla. These will be women with mammographic screen detected small well and moderately differentiated tumours (Hadjiloucas and Bundred, 2000). The impact of sentinel node biopsy in women who have symptomatic large tumours is unproven, and around half of these women will require a second procedure to clear their axilla or radiotherapy as treatment. Even for those women found to have involved sentinel lymph nodes the ability to use early systemic chemotherapy followed by axillary clearance or radiotherapy may provide long-term survival gains. Sentinel node biopsy should not, however, become routine practice until randomised controlled trials have proven its benefit and safety in reducing morbidity. Several randomised controlled trials (including ALMANAC) are currently underway

    Sentinel lymph node biopsy using dye alone method is reliable and accurate even after neo-adjuvant chemotherapy in locally advanced breast cancer - a prospective study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Sentinel lymph node biopsy (SLNB) is now considered a standard of care in early breast cancers with N0 axillae; however, its role in locally advanced breast cancer (LABC) after neo-adjuvant chemotherapy (NACT) is still being debated. The present study assessed the feasibility, efficacy and accuracy of sentinel lymph node biopsy (SLNB) using "dye alone" (methylene blue) method in patients with LABC following NACT.</p> <p>Materials and methods</p> <p>Thirty, biopsy proven cases of LABC that had received three cycles of neo-adjuvant chemotherapy (cyclophosphamide, adriamycin, 5-fluorouracil) were subjected to SLNB (using methylene blue dye) followed by complete axillary lymph node dissection (levels I-III). The sentinel node(s) was/were and the axilla were individually assessed histologically. The SLN accuracy parameters were calculated employing standard definitions. The SLN identification rate in the present study was 100%. The sensitivity of SLNB was 86.6% while the accuracy was 93.3%, which were comparable with other studies done using dual lymphatic mapping method. The SLN was found at level I in all cases and no untoward reaction to methylene blue dye was observed.</p> <p>Conclusions</p> <p>This study confirms that SLNB using methylene blue dye as a sole mapping agent is reasonably safe and almost as accurate as dual agent mapping method. It is likely that in the near future, SLNB may become the standard of care and provide a less morbid alternative to routine axillary lymph node dissection even in patients with LABC that have received NACT.</p
    corecore