4 research outputs found

    Π Π°Π·Ρ€Π°Π±ΠΎΡ‚ΠΊΠ° ΠΌΠ΅Ρ‚ΠΎΠ΄Π° получСния ΠΏΠΎΠ»ΠΈΠΌΠ΅Ρ€Π½Ρ‹Ρ… микросфСр, содСрТащих ΠΈΠΌΠΌΠΎΠ±ΠΈΠ»ΠΈΠ·ΠΎΠ²Π°Π½Π½Ρ‹ΠΉ Π΄ΠΈΠΊΠ»ΠΎΡ„Π΅Π½Π°ΠΊ

    Get PDF
    The dependence of characteristics of microspheres and the kinetics of drug release from the particles on the type and intensity of mechanical action on the emulsion upon the preparation of polymeric microspheres containing encapsulated diclofenac based on a copolymer of lactic and glycolic acids was investigated. According to the results of the research conditions were selected for the production of microspheres with the gradual release of drug from the particles during two weeks. The polymer microspheres are promising for further study and creation of prolonged dosage forms of diclofenac on their basis.На основании ΠΏΡ€ΠΎΠ²Π΅Π΄Π΅Π½Π½Ρ‹Ρ… исслСдований ΠΏΡ€Π΅Π΄Π»ΠΎΠΆΠ΅Π½ ΠΌΠ΅Ρ‚ΠΎΠ΄ получСния ΠΏΠΎΠ»ΠΈΠΌΠ΅Ρ€Π½Ρ‹Ρ… микросфСр с ΠΈΠΌΠΌΠΎΠ±ΠΈΠ»ΠΈΠ·ΠΎΠ²Π°Π½Π½Ρ‹ΠΌ Π΄ΠΈΠΊΠ»ΠΎΡ„Π΅Π½Π°ΠΊΠΎΠΌ. Разработанная мСтодология ΠΈΠΌΠΌΠΎΠ±ΠΈΠ»ΠΈΠ·Π°Ρ†ΠΈΠΈ Π΄ΠΈΠΊΠ»ΠΎΡ„Π΅Π½Π°ΠΊΠ° ΠΏΠΎΠ·Π²ΠΎΠ»ΠΈΠ»Π° ΠΏΠΎΠ»ΡƒΡ‡ΠΈΡ‚ΡŒ ΠΏΠΎΠ»ΠΈΠΌΠ΅Ρ€Π½Ρ‹Π΅ микросфСры с характСристиками, ΠΎΠ±Π΅ΡΠΏΠ΅Ρ‡ΠΈΠ²Π°ΡŽΡ‰ΠΈΠΌΠΈ ΠΏΡ€ΠΎΠ»ΠΎΠ½Π³ΠΈΡ€ΠΎΠ²Π°Π½Π½ΠΎΠ΅ высвобоТдСниС лСкарствСнного вСщСства ΠΈΠ· ΠΏΠΎΠ»ΠΈΠΌΠ΅Ρ€Π½ΠΎΠΉ ΠΌΠ°Ρ‚Ρ€ΠΈΡ†Ρ‹

    Π Π°Π·Ρ€Π°Π±ΠΎΡ‚ΠΊΠ° ΠΈ валидация ΠΌΠ΅Ρ‚ΠΎΠ΄Π° количСствСнного опрСдСлСния Π΄ΠΈΠΊΠ»ΠΎΡ„Π΅Π½Π°ΠΊΠ° Π² ΠΏΠΎΠ»ΠΈΠΌΠ΅Ρ€Π½Ρ‹Ρ… микросфСрах

    Get PDF
    This article describes a new method of determining concentration of active ingredient in diclofenac-loaded polymer microspheres by using HPLC analysis. Proposed method showed better repeatability than more commonly used UV-Vis spectrometry. Isocratic liquid chromatograph with Luna C18 (2) Phenomenex column and UV detector (254 nm) was employed. Various parameters, such as specificity, repeatability, limit of quantification and stability, were measured to validate the method. Chromatogram showed only diclofenac-related peaks, which means specificity was adequate. Recovery was determined using 5 standard diclofenac solutions with known concentration. Repeatability and reproducibility were calculated based on data from two series of microspheres. LOQ was found using standard curve. Stability was observed during 30 days since sample preparation. Based on these results, suggested method successfully passed the validation process and can be used for quality control of diclofenac-loaded microspheres.Π’ ΡΡ‚Π°Ρ‚ΡŒΠ΅ ΠΏΡ€Π΅Π΄Π»ΠΎΠΆΠ΅Π½Π° новая мСтодология количСствСнного опрСдСлСния Π΄ΠΈΠΊΠ»ΠΎΡ„Π΅Π½Π°ΠΊΠ° Π² Π²ΠΈΠ΄Π΅ свободной кислоты, инкапсулированного Π² ΠΏΠΎΠ»ΠΈΠΌΠ΅Ρ€Π½Ρ‹ΠΉ Π½ΠΎΡΠΈΡ‚Π΅Π»ΡŒ, позволившая ΠΏΠΎΠ²Ρ‹ΡΠΈΡ‚ΡŒ Ρ‚ΠΎΡ‡Π½ΠΎΡΡ‚ΡŒ опрСдСлСния содСрТания лСкарствСнного вСщСства

    Development of a method for preparing polymer microspheres containing immobilized diclofenac

    Get PDF
    The dependence of characteristics of microspheres and the kinetics of drug release from the particles on the type and intensity of mechanical action on the emulsion upon the preparation of polymeric microspheres containing encapsulated diclofenac based on a copolymer of lactic and glycolic acids was investigated. According to the results of the research conditions were selected for the production of microspheres with the gradual release of drug from the particles during two weeks. The polymer microspheres are promising for further study and creation of prolonged dosage forms of diclofenac on their basis

    Elaboration and validation of method of quantitative determination of diclofenac in polymeric microspheres

    Get PDF
    This article describes a new method of determining concentration of active ingredient in diclofenac-loaded polymer microspheres by using HPLC analysis. Proposed method showed better repeatability than more commonly used UV-Vis spectrometry. Isocratic liquid chromatograph with Luna C18 (2) Phenomenex column and UV detector (254 nm) was employed. Various parameters, such as specificity, repeatability, limit of quantification and stability, were measured to validate the method. Chromatogram showed only diclofenac-related peaks, which means specificity was adequate. Recovery was determined using 5 standard diclofenac solutions with known concentration. Repeatability and reproducibility were calculated based on data from two series of microspheres. LOQ was found using standard curve. Stability was observed during 30 days since sample preparation. Based on these results, suggested method successfully passed the validation process and can be used for quality control of diclofenac-loaded microspheres
    corecore