    Π Π°Π·Ρ€Π°Π±ΠΎΡ‚ΠΊΠ° ΠΈ валидация ΠΌΠ΅Ρ‚ΠΎΠ΄Π° количСствСнного опрСдСлСния Π΄ΠΈΠΊΠ»ΠΎΡ„Π΅Π½Π°ΠΊΠ° Π² ΠΏΠΎΠ»ΠΈΠΌΠ΅Ρ€Π½Ρ‹Ρ… микросфСрах

    Get PDF
    This article describes a new method of determining concentration of active ingredient in diclofenac-loaded polymer microspheres by using HPLC analysis. Proposed method showed better repeatability than more commonly used UV-Vis spectrometry. Isocratic liquid chromatograph with Luna C18 (2) Phenomenex column and UV detector (254 nm) was employed. Various parameters, such as specificity, repeatability, limit of quantification and stability, were measured to validate the method. Chromatogram showed only diclofenac-related peaks, which means specificity was adequate. Recovery was determined using 5 standard diclofenac solutions with known concentration. Repeatability and reproducibility were calculated based on data from two series of microspheres. LOQ was found using standard curve. Stability was observed during 30 days since sample preparation. Based on these results, suggested method successfully passed the validation process and can be used for quality control of diclofenac-loaded microspheres.Π’ ΡΡ‚Π°Ρ‚ΡŒΠ΅ ΠΏΡ€Π΅Π΄Π»ΠΎΠΆΠ΅Π½Π° новая мСтодология количСствСнного опрСдСлСния Π΄ΠΈΠΊΠ»ΠΎΡ„Π΅Π½Π°ΠΊΠ° Π² Π²ΠΈΠ΄Π΅ свободной кислоты, инкапсулированного Π² ΠΏΠΎΠ»ΠΈΠΌΠ΅Ρ€Π½Ρ‹ΠΉ Π½ΠΎΡΠΈΡ‚Π΅Π»ΡŒ, позволившая ΠΏΠΎΠ²Ρ‹ΡΠΈΡ‚ΡŒ Ρ‚ΠΎΡ‡Π½ΠΎΡΡ‚ΡŒ опрСдСлСния содСрТания лСкарствСнного вСщСства

    Elaboration and validation of method of quantitative determination of diclofenac in polymeric microspheres

    Get PDF
    This article describes a new method of determining concentration of active ingredient in diclofenac-loaded polymer microspheres by using HPLC analysis. Proposed method showed better repeatability than more commonly used UV-Vis spectrometry. Isocratic liquid chromatograph with Luna C18 (2) Phenomenex column and UV detector (254 nm) was employed. Various parameters, such as specificity, repeatability, limit of quantification and stability, were measured to validate the method. Chromatogram showed only diclofenac-related peaks, which means specificity was adequate. Recovery was determined using 5 standard diclofenac solutions with known concentration. Repeatability and reproducibility were calculated based on data from two series of microspheres. LOQ was found using standard curve. Stability was observed during 30 days since sample preparation. Based on these results, suggested method successfully passed the validation process and can be used for quality control of diclofenac-loaded microspheres
    corecore