2 research outputs found
Π Π°Π·ΡΠ°Π±ΠΎΡΠΊΠ° ΠΈ Π²Π°Π»ΠΈΠ΄Π°ΡΠΈΡ ΠΌΠ΅ΡΠΎΠ΄Π° ΠΊΠΎΠ»ΠΈΡΠ΅ΡΡΠ²Π΅Π½Π½ΠΎΠ³ΠΎ ΠΎΠΏΡΠ΅Π΄Π΅Π»Π΅Π½ΠΈΡ Π΄ΠΈΠΊΠ»ΠΎΡΠ΅Π½Π°ΠΊΠ° Π² ΠΏΠΎΠ»ΠΈΠΌΠ΅ΡΠ½ΡΡ ΠΌΠΈΠΊΡΠΎΡΡΠ΅ΡΠ°Ρ
This article describes a new method of determining concentration of active ingredient in diclofenac-loaded polymer microspheres by using HPLC analysis. Proposed method showed better repeatability than more commonly used UV-Vis spectrometry. Isocratic liquid chromatograph with Luna C18 (2) Phenomenex column and UV detector (254 nm) was employed. Various parameters, such as specificity, repeatability, limit of quantification and stability, were measured to validate the method. Chromatogram showed only diclofenac-related peaks, which means specificity was adequate. Recovery was determined using 5 standard diclofenac solutions with known concentration. Repeatability and reproducibility were calculated based on data from two series of microspheres. LOQ was found using standard curve. Stability was observed during 30 days since sample preparation. Based on these results, suggested method successfully passed the validation process and can be used for quality control of diclofenac-loaded microspheres.Π ΡΡΠ°ΡΡΠ΅ ΠΏΡΠ΅Π΄Π»ΠΎΠΆΠ΅Π½Π° Π½ΠΎΠ²Π°Ρ ΠΌΠ΅ΡΠΎΠ΄ΠΎΠ»ΠΎΠ³ΠΈΡ ΠΊΠΎΠ»ΠΈΡΠ΅ΡΡΠ²Π΅Π½Π½ΠΎΠ³ΠΎ ΠΎΠΏΡΠ΅Π΄Π΅Π»Π΅Π½ΠΈΡ Π΄ΠΈΠΊΠ»ΠΎΡΠ΅Π½Π°ΠΊΠ° Π² Π²ΠΈΠ΄Π΅ ΡΠ²ΠΎΠ±ΠΎΠ΄Π½ΠΎΠΉ ΠΊΠΈΡΠ»ΠΎΡΡ, ΠΈΠ½ΠΊΠ°ΠΏΡΡΠ»ΠΈΡΠΎΠ²Π°Π½Π½ΠΎΠ³ΠΎ Π² ΠΏΠΎΠ»ΠΈΠΌΠ΅ΡΠ½ΡΠΉ Π½ΠΎΡΠΈΡΠ΅Π»Ρ, ΠΏΠΎΠ·Π²ΠΎΠ»ΠΈΠ²ΡΠ°Ρ ΠΏΠΎΠ²ΡΡΠΈΡΡ ΡΠΎΡΠ½ΠΎΡΡΡ ΠΎΠΏΡΠ΅Π΄Π΅Π»Π΅Π½ΠΈΡ ΡΠΎΠ΄Π΅ΡΠΆΠ°Π½ΠΈΡ Π»Π΅ΠΊΠ°ΡΡΡΠ²Π΅Π½Π½ΠΎΠ³ΠΎ Π²Π΅ΡΠ΅ΡΡΠ²Π°
Elaboration and validation of method of quantitative determination of diclofenac in polymeric microspheres
This article describes a new method of determining concentration of active ingredient in diclofenac-loaded polymer microspheres by using HPLC analysis. Proposed method showed better repeatability than more commonly used UV-Vis spectrometry. Isocratic liquid chromatograph with Luna C18 (2) Phenomenex column and UV detector (254 nm) was employed. Various parameters, such as specificity, repeatability, limit of quantification and stability, were measured to validate the method. Chromatogram showed only diclofenac-related peaks, which means specificity was adequate. Recovery was determined using 5 standard diclofenac solutions with known concentration. Repeatability and reproducibility were calculated based on data from two series of microspheres. LOQ was found using standard curve. Stability was observed during 30 days since sample preparation. Based on these results, suggested method successfully passed the validation process and can be used for quality control of diclofenac-loaded microspheres