275 research outputs found

    Measurement method of in-situ tensile strength of SiC fiber in SiC/SiC composite

    Get PDF
    Please click Additional Files below to see the full abstrac

    The Influence of Hyperactivity of the Hypothalamic-pituitary-adrenal Axis and Hyperglycemia on the 5-HT2A Receptor-mediated Wet-dog Shake Responses in Rats

    Get PDF
    Hyperactivity of the hypothalamic-pituitary-adrenal (HPA) axis induces hyperglycemia and serotonin (5-HT)2A receptor supersensitivity. In the present study, to investigate the effect of hyperglycemia on the function of 5-HT2A receptors, we compared the 5-HT2A receptor-mediated wet-dog shake responses in rats treated with adrenocorticotropic hormone (ACTH), dexamethasone and streptozotocin. ACTH (100 &#956;g/rat per day, s.c.), dexamethasone (1 mg/kg per day, s.c.) and streptozotocin (60 mg/kg, i.p.) produced significant hyperglycemia at 14 days after the start of these treatments, and the hyperglycemia was most pronounced in the streptozotocin-treated rats. The wet-dog shake responses induced by (±)-1-(2,5-dimethoxy-4-iodophenyl)-2-aminopropane (DOI), a 5-HT2A receptor agonist, were significantly enhanced at 14 days after repeated treatment with ACTH and dexamethasone. However, streptozotocin-induced diabetes had no effect on the wet-dog shake responses. The results of the present study suggest that hyperglycemia is not strongly associated with the enhanced susceptibility of 5-HT2A receptors under the condition of hyperactivity of the HPA axis.</p

    Agreement between continuous cardiac output measured by the fourth-generation FloTrac/Vigileo system and a pulmonary artery catheter in adult liver transplantation

    Get PDF
    In liver transplantation for end-stage liver failure, monitoring of continuous cardiac output (CCO) is used for circulatory management due to hemodynamic instability. CCO is often measured using the minimally invasive FloTrac/Vigileo system (FVS-CCO), instead of a highly invasive pulmonary artery catheter (PAC-CCO). The FVS has improved accuracy due to an updated cardiac output algorithm, but the effect of this change on the accuracy of FVS-CCO in liver transplantation is unclear. In this study, we assessed agreement between fourth-generation FVS-CCO and PAC-CCO in 20 patients aged ≥ 20 years who underwent scheduled or emergency liver transplantation at Kyoto University Hospital from September 2019 to June 2021. Consent was obtained before surgery and data were recorded throughout the surgical period. Pearson correlation coefficient (r), Bland–Altman and 4-quadrant plot analyses were performed on the extracted data. A total of 1517 PAC-CCO vs. FVS-CCO data pairs were obtained. The mean PAC-CCO was 8.73 L/min and the mean systemic vascular resistance was 617.5 dyne·s·cm⁻⁵, r was 0.48, bias was 1.62 L/min, the 95% limits of agreement were − 3.04 to 6.27, and the percentage error was 54.36%. These results show that agreement and trending between fourth-generation FVS-CCO and PAC-CCO are low in adult liver transplant recipients

    Experience with the Vibrant Soundbridge RW-Coupler for round window Vibroplasty with tympanosclerosis

    Get PDF
    Usage of the Vibrant Soundbridge (VSB) with round window (RW)-Coupler placement at the RW has been shown to successfully treat mixed hearing loss. Coupling between the VSB's floating mass transducer (FMT) and the RW membrane is difficult in the case of sclerosis in the RW and drilling down the bony lip until the RW membrane can be seen completely can possibly induce a perilymphatic fistula. A 68-year-old woman who had bilateral mixed hearing loss with sclerosis in the RW due to tympanosclerosis underwent a RW-Vibroplasty with a RW-Coupler. Speech discrimination scores in quiet and noise and functional gain with the VSB with RW-Coupler were better than those using a conventional hearing aid. The results of the present case have shown the feasibility of implanting a VSB with RW-Coupler in patients with mixed hearing loss due to tympanosclerosis.ArticleACTA OTO-LARYNGOLOGICA. 132(6):676-682 (2012)journal articl

    Language development in Japanese children who receive cochlear implant and/or hearing aid

    Get PDF
    Objectives: This study aimed to investigate a wide variety of factors that influence auditory, speech, and language development following pediatric cochlear implantation (CI). Study design: Prospective collection of language tested data in profound hearing-impaired children. Hypothesis: Pediatric CI can potentially be effective to development of practical communication skills and early implantation is more effective. Methods: We proposed a set of language tests (assessment package of the language development for Japanese hearing-impaired children; ALADJIN) consisting of communication skills testing (test for question-answer interaction development; TQAID), comprehensive (Peabody Picture Vocabulary Test-Revised; PVT-R and Standardized Comprehension Test for Abstract Words; SCTAW) and productive vocabulary (Word Fluency Test; WFT), and comprehensive and productive syntax (Syntactic processing Test for Aphasia; STA). Of 638 hearing-impaired children recruited for this study, 282 (44.2%) with >70 dB hearing impairment had undergone CI. After excluding children with low birth weight (11 points on the Pervasive Developmental Disorder ASJ Rating Scale for the test of autistic tendency, and those <2 SD on Raven's Colored Progressive Matrices for the test of non-verbal intelligence, 190 children were subjected to this set of language tests. Results: Sixty children (31.6%) were unilateral CI-only users, 128 (67.4%) were CI-hearing aid (HA) users, and 2 (1.1%) were bilateral CI users. Hearing loss level of CI users was significantly (p < 0.01) worse than that of HA-only users. However, the threshold level, maximum speech discrimination score, and speech intelligibility rating in CI users were significantly (p < 0.01) better than those in HA-only users. The scores for PVT-R (p < 0.01), SCTAW, and WET in CI users were better than those in HA-only users. STA and TQAID scores in CI-HA users were significantly (p < 0.05) better than those in unilateral CI-only users. The high correlation (r = 0.52) has been found between the age of CI and maximum speech discrimination score. The scores of speech and language tests in the implanted children before 24 months of age have been better than those in the implanted children after 24 months of age. Conclusions: We could indicate that CI was effective for language development in Japanese hearing-impaired children and early CI was more effective for productive vocabulary and syntax.ArticleINTERNATIONAL JOURNAL OF PEDIATRIC OTORHINOLARYNGOLOGY. 76(3):433-438 (2012)journal articl

    Matrix Product Renormalization Group: Potential Universal Quantum Many-Body Solver

    Full text link
    The density matrix renormalization group (DMRG) is a celebrated tensor network algorithm, which computes the ground states of one-dimensional quantum many-body systems very efficiently. Here we propose an improved formulation of continuous tensor network algorithms, which we name a matrix product renormalization group (MPRG). MPRG is a universal quantum many-body solver, which potentially works at both zero and finite temperatures, in two and higher dimensions, and is even applicable to open quantum systems. Furthermore, MPRG does not rely on any variational principles and thus supports any kind of non-Hermitian systems in any dimension. As a demonstration, we present critical properties of the Yang-Lee edge singularity in one dimension as a representative non-Hermitian system.Comment: 5 pages, 3 figures, 2 table

    Comparison of the diagnostic value of 3 T MRI after intratympanic injection of GBCA, electrocochleography, and the glycerol test in patients with Meniere's disease

    Get PDF
    Conclusion. 3 T MRI after intratympanic injection of gadolinium-based contrast agent (GBCA) is more useful for the diagnosis of endolymphatic hydrops compared with the glycerol test and electrocochleography (ECoG). Objective: To investigate the relationship between 3 T MRI after intratympanic injection of GBCA, the glycerol test, and ECoG in patients with Meniere's disease (MD). Methods: A total of 20 patients with MD were evaluated. Diluted gadodiamide (a gadolinium-based contrast agent) was administered to the bilateral tympanic cavity by injection through the tympanic membrane. After 24 h, the endolymphatic hydrops was evaluated by a 3.0 T MR scanner. To investigate cochlear hydrops, the glycerol test and ECoG were carried out in all patients. Results: A positive result was observed in 11 patients (55%) in the glycerol test and in 12 patients (60%) by ECoG. The incidence of positive findings when evaluating the same patients with both the glycerol test and ECoG increased to 75%. Nineteen of 20 (95%) patients showed positive results for 3 T MRI.ArticleACTA OTO-LARYNGOLOGICA. 132(2):141-145 (2012)journal articl
    corecore