805 research outputs found

    Viscous slip coefficients for binary gas mixtures measured from mass flow rates through a single microtube.

    Get PDF
    International audienceArticles you may be interested in A slip model for rarefied gas flows above a moving surface with mass transfe

    A new method to establish the rational extent of hepatic resection for advanced gallbladder cancer using dye injection through the cystic artery

    Get PDF
    BackgroundHepatic resection has been indicated to eliminate cancer at the surgical margin in cases of advanced gallbladder carcinoma, but there is considerable controversy about the reasonable extent of liver resection. A new on‐table dye injection technique has been introduced to determine the venous drainage of the gallbladder and ascertain the amount of liver to remove.MethodsIn four hepatic resections for pT2 gallbladder cancer, indocyanine green solution (25 mg/20 ml) was injected over a period of 30 seconds through the cystic artery. The stained area of the liver surface was completely resected, maintaining a margin of at least 2 cm from the gallbladder.ResultsThe entire serosal surface of the gallbladder takes on a light green stain immediately after dye injection, and then the liver surface around the gallbladder gradually becomes stained with a clear demarcation line. The distance between the demarcation line and the gallbladder ranged from 1.0 to 5.0 cm. The extent of the stained area differed from one individual to another. Histopathological examination of resected liver specimens revealed that one of the four resected livers had micrometastasis in the portal area 27 mm from the gallbladder wall and there were no cancer cells at the surgical margins. No recurrence has been seen in any of our 4 patients at 16–26 months after operation.DiscussionThe dye injection method is useful in determining the appropriate extent of hepatic resection for advanced gallbladder cancer, as it is possible to determine the necessary and sufficient amount of liver parenchyma that should be removed according to the perfusion area of the cystic veins in each individual patient

    The linear variable differential transformer (LVDT) position sensor for gravitational wave interferometer low-frequency controls

    Get PDF
    Low-power, ultra-high-vacuum compatible, non-contacting position sensors with nanometer resolution and centimeter dynamic range have been developed, built and tested. They have been designed at Virgo as the sensors for low-frequency modal damping of Seismic Attenuation System chains in Gravitational Wave interferometers and sub-micron absolute mirror positioning. One type of these linear variable differential transformers (LVDTs) has been designed to be also insensitive to transversal displacement thus allowing 3D movement of the sensor head while still precisely reading its position along the sensitivity axis. A second LVDT geometry has been designed to measure the displacement of the vertical seismic attenuation filters from their nominal position. Unlike the commercial LVDTs, mostly based on magnetic cores, the LVDTs described here exert no force on the measured structure

    Retinal glycoprotein enrichment by concanavalin a enabled identification of novel membrane autoantigen synaptotagmin-1 in equine recurrent uveitis.

    Get PDF
    Complete knowledge of autoantigen spectra is crucial for understanding pathomechanisms of autoimmune diseases like equine recurrent uveitis (ERU), a spontaneous model for human autoimmune uveitis. While several ERU autoantigens were identified previously, no membrane protein was found so far. As there is a great overlap between glycoproteins and membrane proteins, the aim of this study was to test whether pre-enrichment of retinal glycoproteins by ConA affinity is an effective tool to detect autoantigen candidates among membrane proteins. In 1D Western blots, the glycoprotein preparation allowed detection of IgG reactions to low abundant proteins in sera of ERU patients. Synaptotagmin-1, a Ca2+-sensing protein in synaptic vesicles, was identified as autoantigen candidate from the pre-enriched glycoprotein fraction by mass spectrometry and was validated as a highly prevalent autoantigen by enzyme-linked immunosorbent assay. Analysis of Syt1 expression in retinas of ERU cases showed a downregulation in the majority of ERU affected retinas to 24%. Results pointed to a dysregulation of retinal neurotransmitter release in ERU. Identification of synaptotagmin-1, the first cell membrane associated autoantigen in this spontaneous autoimmune disease, demonstrated that examination of tissue fractions can lead to the discovery of previously undetected novel autoantigens. Further experiments will address its role in ERU pathology

    Dynamics of a lattice Universe

    Get PDF
    We find a solution to Einstein field equations for a regular toroidal lattice of size L with equal masses M at the centre of each cell; this solution is exact at order M/L. Such a solution is convenient to study the dynamics of an assembly of galaxy-like objects. We find that the solution is expanding (or contracting) in exactly the same way as the solution of a Friedman-Lema\^itre-Robertson-Walker Universe with dust having the same average density as our model. This points towards the absence of backreaction in a Universe filled with an infinite number of objects, and this validates the fluid approximation, as far as dynamics is concerned, and at the level of approximation considered in this work.Comment: 14 pages. No figure. Accepted version for Classical and Quantum Gravit

    Current status of the CLIO project

    Full text link
    CLIO (Cryogenic Laser Interferometer Observatory) is a Japanese gravitational wave detector project. One of the main purposes of CLIO is to demonstrate thermal-noise suppression by cooling mirrors for a future Japanese project, LCGT (Large-scale Cryogenic Gravitational Telescope). The CLIO site is in Kamioka mine, as is LCGT. The progress of CLIO between 2005 and 2007 (room- and cryogenic-temperature experiments) is introduced in this article. In a room-temperature experiment, we made efforts to improve the sensitivity. The current best sensitivity at 300 K is about 6×1021/Hz6 \times 10^{-21} /\sqrt{\rm Hz} around 400 Hz. Below 20 Hz, the strain (not displacement) sensitivity is comparable to that of LIGO, although the baselines of CLIO are 40-times shorter (CLIO: 100m, LIGO: 4km). This is because seismic noise is extremely small in Kamioka mine. We operated the interferometer at room temperature for gravitational wave observations. We obtained 86 hours of data. In the cryogenic experiment, it was confirmed that the mirrors were sufficiently cooled (14 K). However, we found that the radiation shield ducts transferred 300K radiation into the cryostat more effectively than we had expected. We observed that noise caused by pure aluminum wires to suspend a mirror was suppressed by cooling the mirror.Comment: 8 pages, 9 figures. Amaldi7 proceedings, J. Phys.: Conf. Ser. (accepted

    Investigation of mechanical losses of thin silicon flexures at low temperatures

    Full text link
    The investigation of the mechanical loss of different silicon flexures in a temperature region from 5 to 300 K is presented. The flexures have been prepared by different fabrication techniques. A lowest mechanical loss of 3×1083\times10^{-8} was observed for a 130 μ\mum thick flexure at around 10 K. While the mechanical loss follows the thermoelastic predictions down to 50 K a difference can be observed at lower temperatures for different surface treatments. This surface loss will be limiting for all applications using silicon based oscillators at low temperatures. The extraction of a surface loss parameter using different results from our measurements and other references is presented. We focused on structures that are relevant for gravitational wave detectors. The surface loss parameter αs\alpha_s = 0.5 pm was obtained. This reveals that the surface loss of silicon is significantly lower than the surface loss of fused silica.Comment: 16 pages, 7 figure
    corecore