34 research outputs found

    Irradiation by a Combination of Different Peak-Wavelength Ultraviolet-Light Emitting Diodes Enhances the Inactivation of Influenza A Viruses

    Get PDF
    Influenza A viruses (IAVs) pose a serious global threat to humans and their livestock. This study aimed to determine the ideal irradiation by ultraviolet-light emitting diodes (UV-LEDs) for IAV disinfection. We irradiated the IAV H1N1 subtype with 4.8 mJ/cm2 UV using eight UV-LEDs [peak wavelengths (WL) = 365, 310, 300, 290, 280, 270, and 260 nm)] or a mercury low pressure (LP)-UV lamp (Peak WL = 254 nm). Inactivation was evaluated by the infection ratio of Madin–Darby canine kidney (MDCK) cells or chicken embryonated eggs. Irradiation by the 260 nm UV-LED showed the highest inactivation among all treatments. Because the irradiation-induced inactivation effects strongly correlated with damage to viral RNA, we calculated the correlation coefficient (RAE) between the irradiant spectrum and absorption of viral RNA. The RAE scores strongly correlated with the inactivation by the UV-LEDs and LP-UV lamp. To increase the RAE score, we combined three different peak WL UV-LEDs (hybrid UV-LED). The hybrid UV-LED (RAE = 86.3) significantly inactivated both H1N1 and H6N2 subtypes to a greater extent than 260 nm (RAE = 68.6) or 270 nm (RAE = 42.2) UV-LEDs. The RAE score is an important factor for increasing the virucidal effects of UV-LED irradiation

    紫外線発光ダイオード照射は宿主細胞内でのウイルスRNAの複製と転写を抑制することでA型インフルエンザウイルスを不活化する

    Get PDF
    Influenza A viruses (IAVs) pose a serious global threat to humans and their livestock, especially poultry and pigs. This study aimed to investigate how to inactivate IAVs by using different ultraviolet-light-emitting diodes (UV-LEDs). We developed sterilization equipment with light-emitting diodes (LEDs) those peak wavelengths were 365 nm (UVA-LED), 310 nm (UVB-LED), and 280 nm (UVC-LED). These UV-LED irradiations decreased dose fluence-dependent plaque-forming units of IAV H1N1 subtype (A/Puerto Rico/8/1934) infected Madin-Darby canine kidney (MDCK) cells, but the inactivation efficiency of UVA-LED was significantly lower than UVB- and UVC-LED. UV-LED irradiations did not alter hemagglutination titer, but decreased accumulation of intracellular total viral RNA in infected MDCK cells was observed. Additionally, UV-LED irradiations suppressed the accumulation of intracellular mRNA (messenger RNA), vRNA (viral RNA), and cRNA (complementary RNA), as measured by strand-specific RT-PCR. These results suggest that UV-LEDs inhibit host cell replication and transcription of viral RNA. Both UVB- and UVC-LED irradiation decreased focus-forming unit (FFU) of H5N1 subtype (A/Crow/Kyoto/53/2004), a highly pathogenic avian IAV (HPAI), in infected MDCK cells, and the amount of FFU were lower than the H1N1 subtype. From these results, it appears that IAVs may have different sensitivity among the subtypes, and UVB- and UVC-LED may be suitable for HPAI virus inactivation

    Identification of Genes Associated with Sensitivity to Ultraviolet A (UVA) Irradiation by Transposon Mutagenesis of Vibrio parahaemolyticus

    Get PDF
    Ultraviolet (UV) irradiation is used to disinfect water and food and can be classified as UVA (detected at wavelengths 320–400 nm), UVB (280–320 nm), and UVC (<280 nm). We developed a method for UVA sterilization of equipment with a UVA-light-emitting diode (LED); however, a high rate of fluence was needed to promote pathogen inactivation. The aim of this study was to identify genes associated with UVA sensitivity with the goal of improving UVA-LED-mediated bactericidal activity. We constructed a transposon-mutant library of Vibrio parahaemolyticus and selected six mutants with high sensitivity to UVA irradiation. Genes associated with this phenotype include F-type H+-transporting ATPases (atp), as well as those involved in general secretion (gsp), and ubiquinone and terpenoid-quinone biosynthesis (ubi). Gene complementation resulted in decreased sensitivity to UVA-LED. The atp mutants had lower intracellular adenosine triphosphate (ATP) concentrations than the wild-type treatment, with 20 mM L-serine resulting in elevated ATP concentrations and decreased sensitivity to UVA-LED. The gsp mutants exhibited high levels of extracellular protein transport and the ubi mutants exhibited significantly different intracellular concentrations of ubiquinone-8. Taken together, our results suggest that the protein products of the atp, gsp, and ubi genes may regulate sensitivity to UVA irradiation

    Inactivation of ESBL-E. coli

    Get PDF
    The prevalence of extended-spectrum β-lactamase (ESBL)-producing Escherichia coli is increasing rapidly and spreading worldwide, particularly in Asia, compared to other regions. In the last ten years, in our hospital, in particular, there has been a < 30% increase. To prevent the spread of ESBL in hospitals and the community, the ultraviolet (UV) A-light-emitting diode (LED) irradiation device was used to inactivate ESBL-E. coli in human livestock and the environment. ESBL-E. coli and E. coli bacterial samples were collected from patients at Tokushima University Hospital (Tokushima City, Japan). The UVA-LED irradiation system had 365 nm single wavelength, and the current of the circuit was set to 0.23 or 0.50 A consistently. Results demonstrated that UVA-LED was useful for the inactivation of ESBL-E. coli and E. coli. The minimum energy dosage required to inactivate ESBL-E. coli and E. coli was 40.76 J/cm2 (45 min) in the first type of UVA-LED and 38.85 J/cm2 (5 min) in the second type. There were no significant differences between ESBL-E. coli and E. coli. The inactivation of ESBL-E. coli was dependent on energy. These findings suggest that UVA-LED with 365 nm single wavelength could be useful for surface decontamination in healthcare facilities

    Combined treatment of UVA and antibiotics

    Get PDF
    The presence of antibiotics in the environment and their subsequent impact on the development of multi-antibiotic resistant bacteria has raised concerns globally. Consequently, much research is focused on a method to produce a better disinfectant. We have established a disinfectant system using UVA-LED that inactivates pathogenic bacteria. We assessed the bactericidal efficiency of a combination of UVA-LED and antibiotics against Vibrio parahaemolyticus. Combined use of antibiotic drugs and UVA irradiation was more bactericidal than UVA irradiation or antibacterial drugs alone. The bactericidal synergy was observed at low concentrations of each drug that are normally unable to kill the bacteria. This combination has the potential to become a sterilization technology

    UVA-LED disinfect hydroponic solution

    Get PDF
    The number of plant factories in which crops are cultivated in an artificial environment has been increasing every year. In cultivation techniques involving hydroponics, plants are supplied with a circulating nutrient solution, which can become contaminated by pathogens that can propagate and spread throughout plant factories. Therefore, strategies to disinfect hydroponic nutrient solutions are needed. In this study, we developed a new disinfection device equipped with an ultraviolet A (UVA) light emitting diode (LED) that can be used to disinfect hydroponic nutrient solutions in plant factories. We first evaluated the basic disinfection capability of the device and then estimated its bactericidal effect in a small scale model system. The log survival ratio was related to UVA irradiation fluence and the volume of nutrient solution. From the assay results, we devised a kinetics equation to describe the relationship between nutrient solution volume, log survival ratio, and UVA fluence. Together our results show that UVA irradiation could be used to disinfect hydroponic nutrient solutions, and the derived kinetics equations can be used to determine optimal conditions, such as nutrient solution volume, UVA irradiation, and killing activity, to develop devices that disinfect hydroponic nutrient solutions

    Infection risk in hemodialysis patient

    Get PDF
    Chronic care patients undergoing hemodialysis for treatment of end-stage renal failure experience higher rates of bloodstream-associated infection due to the patients' compromised immune system and management of the bloodstream through catheters. Staphylococcus species are a common cause of hemodialysis catheter-related bloodstream infections. We investigated environmental bacterial contamination of dialysis wards and contamination of hemodialysis devices to determine the source of bacteria for these infections. All bacterial samples were collected by the swab method and the agarose stamp method. And which bacterium were identified by BBL CRYSTAL Kit or 16s rRNA sequences. In our data, bacterial cell number of hemodialysis device was lower than environment of patient surrounds. But Staphylococcus spp. were found predominantly on the hemodialysis device (46.8%), especially on areas frequently touched by healthcare-workers (such as Touch screen). Among Staphylococcus spp., Staphylococcus epidermidis was most frequently observed (42.1% of Staphylococcus spp.), and more surprising, 48.2% of the Staphylococcus spp. indicated high resistance for methicillin. Our finding suggests that hemodialysis device highly contaminated with bloodstream infection associated bacteria. This study can be used as a source to assess the risk of contamination-related infection and to develop the cleaning system for the better prevention for bloodstream infections in patients with hemodialysis

    Japanese Orthopaedic Association Hip Disease Evaluation Questionnaire (JHEQ): a patient-based evaluation tool for hip-joint disease. The Subcommittee on Hip Disease Evaluation of the Clinical Outcome Committee of the Japanese Orthopaedic Association

    Get PDF
    AbstractBackgroundThe Japanese Orthopaedic Association Hip Score is widely used in Japan, but this tool is designed to reflect the viewpoint of health-care providers rather than that of patients. In gauging the effect of medical therapies in addition to clinical results, it is necessary to assess quality of life (QOL) from the viewpoint of patients. However, there is no tool evaluating QOL for Japanese patients with hip-joint disease.MethodsWith the aim of more accurately classifying QOL for Japanese patients with hip-joint disease, we prepared a questionnaire with 58 items for the survey derived from 464 opinions obtained from approximately 100 Japanese patients with hip-joint disease and previously devised evaluation criteria. In the survey, we collected information on 501 cases, and 402 were subjected to factor analysis. From this, we formulated three categories—movement, mental, and pain—each comprising 7 items, for a total of 21 items to be used as evaluation criteria for hip-joint function.ResultsThe Cronbach’s α coefficients for the three categories were 0.93, 0.93, and 0.95, respectively, indicating the high reliability of the evaluation criteria. The 21 items included some related to the Asian lifestyle, such as use of a Japanese-style toilet and rising from the floor, which are not included in other evaluation tools.ConclusionsThis self-administered questionnaire may become a useful tool in the evaluation of not only Japanese patients, but also of members of other ethnic groups who engage in deep flexion of the hip joint during daily activities

    Glutamine protects small intestinal mucosa

    Get PDF
    Supportive therapy during chemotherapy has become essential, but effective preventive therapies to gastrointestinal mucosal injury are few. We investigated the efficacy of glutamine in rat anticancer drug-induced enteritis model. In this study, we used twenty male SD rats. They were divided into control, 5-fluorouracil (5-FU) (orally administered at 20mg/kg day), 5-FU+glutamine (1000 mg/kg/day) and 5-FU+glutamine+fiber and oligosaccharide (GFO[○R]) (1000 mg/kg/day) groups. All groups were sacrificed on day 6 and upper jejunums were excised. The jejunal villous height was measured in specimens. IgA level in jejunal washing solution, and serum diamine oxidase activity were also measured. The jejunal villous height was recognized as shorter in the specimen from 5-FU treated rats compared with 5-FU+glutamine treated rats (p<0.001). Serum diamine oxidase activity in 5-FU+glutamine group were significantly superior to that in 5-FU group (p=0.028). IgA level in jejunal washing solution tended to be higher in 5-FU+glutamine group than that in 5-FU group (p=0.076). On the other hand, serum diamine oxidase activity and IgA level in jejunal washing solution showed no significant difference between 5-FU+GFO and 5-FU treatment group. Our results suggest that glutamine showed protective effects on mucosal injury of small intestine in rat anticancer drug-induced enteritis model

    Research and development of exclusive equipment for cell-free and concentrated ascites reinfusion therapy (CART) by medical-industrial, hospital-university, and multifarious worker cooperation

    Get PDF
    Cell-free and concentrated ascites reinfusion therapy(CART)is an effective and safe therapy for patients with refractory ascites or pleural effusion. CART was initially indicated for cirrhotic ascites, and has come to be widely used for malignant ascites. Recently, cancer therapy that applies cancer cells obtained by filtration process is considered, and CART attracts attention as one of the important therapies to support future cancer therapy. However, the numbers of CART in Japan is not sufficient because the equipment for CART is high price and large. Additionally, the specialized medical staff such as clinical engineers is necessary for CART because of complicated operation. Therefore, we think that development of next-generation type equipment for CART that can be performed safely, easily, and reliably is necessary. We could develop the exclusive equipment for CART according to the project management by multifarious worker cooperation in five years
    corecore