40 research outputs found

    Dual-band filtering power divider with capacitor-loaded centrally coupled-line resonators

    Get PDF
    In this paper, a dual-band filtering power divider (DB-FPD) with capacitor-loaded centrally coupled-line resonators (CLCCLRs) is presented. The proposed design utilizes four CLCCLRs, two resistors and one inductor to achieve the dual functions of dual-band filtering and power division. By altering the values of the capacitors loaded at the ends of the coupled-lines, the center frequencies of the two passbands can be adjusted independently. It is noted that changing one passband will not affect the other. For demonstration, a microstrip filtering power divider is designed, fabricated and measured. Under different values of the loaded capacitors, experimental results show that the lower band center frequency varies from 0.7 GHz to 1.0 GHz with the upper band fixed at 1.75 GHz, whereas the upper band center frequency varies from 1.65 GHz to 1.95 GHz when the lower band is fixed at 1.0 GHz. The measured results show good agreement with the simulations

    Highly integrated PA-PIFA with a wide frequency tuning range

    Get PDF

    A nomogram based on inflammation and nutritional biomarkers for predicting the survival of breast cancer patients

    Get PDF
    BackgroundWe aim to develop a new prognostic model that incorporates inflammation, nutritional parameters and clinical-pathological features to predict overall survival (OS) and disease free survival (DFS) of breast cancer (BC) patients.MethodsThe study included clinicopathological and follow-up data from a total of 2857 BC patients between 2013 and 2021. Data were randomly divided into two cohorts: training (n=2001) and validation (n=856) cohorts. A nomogram was established based on the results of a multivariate Cox regression analysis from the training cohorts. The predictive accuracy and discriminative ability of the nomogram were evaluated by the concordance index (C-index) and calibration curve. Furthermore, decision curve analysis (DCA) was performed to assess the clinical value of the nomogram.ResultsA nomogram was developed for BC, incorporating lymphocyte, platelet count, hemoglobin levels, albumin-to-globulin ratio, prealbumin level and other key variables: subtype and TNM staging. In the prediction of OS and DFS, the concordance index (C-index) of the nomogram is statistically greater than the C-index values obtained using TNM staging alone. Moreover, the time-dependent AUC, exceeding the threshold of 0.7, demonstrated the nomogram’s satisfactory discriminative performance over different periods. DCA revealed that the nomogram offered a greater overall net benefit than the TNM staging system.ConclusionThe nomogram incorporating inflammation, nutritional and clinicopathological variables exhibited excellent discrimination. This nomogram is a promising instrument for predicting outcomes and defining personalized treatment strategies for patients with BC

    Analysis on contamination of Bacillus cereus in foodstuff in Jilin Province from 2011 to 2019

    Get PDF
    Objective To understand the contamination of Bacillus cereus in foodstuff of Jilin Province from 2011 to 2019, and to provide theoretical basis for food safety monitoring and prevention of foodborne diseases. Methods Totally 3 173 samples were collected from the catering service and circulation of nine prefecture (city) levels in Jilin Province from 2011 to 2019. Bacillus cereus in food was detected according to the method of GB 4789.14-2014 national food safety standard microbiological examination of food. The detection rate was analyzed by rate, composition ratio and χ2 test. Results Among 3 173 food samples from 2011 to 2019 in Jilin Province, the total detection rate of Bacillus cereus was 23.6% (750/3 173), the highest was in 2015 (38.5%, 62/161), and the lowest was in 2017 (11.8%, 20/170). Baishan City had the highest detection rate (35.8%, 139/388), followed by Yanbian Prefecture (31.4%, 97/309), and Siping City had the lowest detection rate (15.3%, 76/496). The detection rate of egg and egg products was the highest (60.0%, 3/5), followed by milk and dairy products (39.3%, 114/290) and infant food (31.1%, 185/595). Contamination of Bacillus cereus was the highest in department stores (32.4%, 22/68), followed by snack bars and beverage stores (30.9%, 43/139), and fast food stores (29.1%, 25/86). The median (interquartile interval) of the detection result of Bacillus cereus by colony forming units method was 5.8 (2.9, 8.7) CFU/g (mL), and the median (interquartile interval) of that by most probable number method was 6.4 (3.2, 9.6) MPN/g (mL). Conclusion There were different degrees of Bacillus cereus contamination in foodstuff in Jilin Province. Among the different cities, foodstuff samples collected from Baishan City was much more serious. Eggs and egg products, milk and dairy products were the main contaminated food. Safety monitoring and management of the snack bar, beverage shop and places in department store should be strengthen

    A Schottky diode and FET‐paralleled analogue predistorter for 5G small‐cell base stations

    No full text

    Broadband Frequency-Selective Rasorber With Varactor-Tunable Interabsorption Band Transmission Window

    No full text
    corecore