129 research outputs found

    Pullout tests on the connection to an existing foundation of a steel warehouse rebuilt after the 2012 Emilia (Italy) earthquakes

    Get PDF
    The tests described in this paper were aimed at evaluating the tensile capacity of the anchorages connecting an automated pallet warehouse with an existing RC foundation. The warehouse is a new steel structure erected in the place of a previous warehouse collapsed due to the Emilia earthquake, but whose foundation remained undamaged. The investigated fastening consists of 10 post-installed, bonded threaded rods with diameter (d) and embedment depth (h(ef)) of 20 and 500 mm, respectively. Neither anchor arrangement nor embedment depth (h(ef) > 20d) was covered by current standards for fastening design. To reproduce the in-situ actual conditions of the fastening, an unconfined test configuration was used. The maximum loads achieved were more than 3 times greater than the seismic demand for the fastening. The tests highlighted the crucial role played by the reinforcing steel which was present in the foundation. Concrete-related failure mechanisms, such as the combined pullout and concrete cone failure mechanism typical of bonded anchors, were not activated. The observed crack patterns rather suggest the onset of a flexural failure mechanism of the concrete slab. This feature is confirmed by analytical calculations showing that, at the maximum loads achieved in the tests, the top reinforcement was likely to be yielded. In six preliminary unconfined tension tests on single anchors, steel rod failure was achieved, associated with limited cracking of the concrete surface in proximity of the anchor

    A public early intervention approach to first-episode psychosis: Treated incidence over 7 years in the Emilia-Romagna region

    Get PDF
    AimTo estimate the treated incidence of individuals with first-episode psychosis (FEP) who contacted the Emilia-Romagna public mental healthcare system (Italy); to examine the variability of incidence and user characteristics across centres and years. MethodsWe computed the raw treated incidence in 2013-2019, based on FEP users aged 18-35, seen within or outside the regional program for FEP. We modelled FEP incidence across 10 catchment areas and 7 years using Bayesian Poisson and Negative Binomial Generalized Linear Models of varying complexity. We explored associations between user characteristics, study centre and year comparing variables and socioclinical clusters of subjects. ResultsThousand three hundred and eighteen individuals were treated for FEP (raw incidence: 25.3 / 100.000 inhabitant year, IQR: 15.3). A Negative Binomial location-scale model with area, population density and year as predictors found that incidence and its variability changed across centres (Bologna: 36.55; 95% CrI: 30.39-43.86; Imola: 3.07; 95% CrI: 1.61-4.99) but did not follow linear temporal trends or density. Centers were associated with different user age, gender, migrant status, occupation, living conditions and cluster distribution. Year was associated negatively with HoNOS score (R = -0.09, p < .001), duration of untreated psychosis (R = -0.12, p < .001) and referral type. ConclusionsThe Emilia-Romagna region presents a relatively high but variable incidence of FEP across areas, but not in time. More granular information on social, ethnic and cultural factors may increase the level of explanation and prediction of FEP incidence and characteristics, shedding light on social and healthcare factors influencing FEP

    Bending tests to estimate the axial force in slender beams with unknown boundary conditions

    No full text
    This paper presents a static method for the axial load identification of slender prismatic beams with uncertain length and unknown boundary conditions as is typical of struts and ties of truss structures or tie-rods of arches and vaults. The proposed method requires the knowledge of the beam flexural rigidity only. Flexural displacements or curvatures are measured at five cross sections of the beam subjected to an additional concentred lateral load. Unlike analogous dynamic methods, any set of experimental data may be used in the identification algorithm. The proposed algorithm is verified by means of many numerical and experimental tests on beams having different boundary conditions. Excellent estimates of the axial forces are obtained when the greatest possible distance between sensors is adopted, even if in the presence of high values of the axial forces very accurate displacement measurements are required

    Il cantiere rinascimentale ferrarese: dal rilievo tecnico-costruttivo al progetto di conservazione. La sfida posta dalla nuova classificazione sismica.

    No full text
    Cofin 2004. Sicurezza e conservazione degli edifici storici in funzione delle tipologie edilizie, della concezione costruttiva e dei materiali. Coordinatore Nazionale: Prof. L. Bind

    Updating italian design guide CNR DT-205/2007 in view of recent research findings: requirements for pultruded FRP profiles

    Get PDF
    A discussion on some design rules for pultruded fiber-reinforced plastic (PFRP) profiles reported by guideline CNR DT-205/2007 from National Research Council of Italy is presented in the paper. At eight years after approval of this technical document, several changes and improvements are required following recent research findings, and supplemental design rules should be incorporated into a future revision. The general framework for the design of columns and beams is outlined. A new closed-form expression for the local buckling moment for beams in major-axis bending is presented

    Cyclic test on a precast reinforced concrete column-to-foundation grouted duct connection

    No full text
    A full-scale specimen of a column-to-foundation grouted duct connection suited for buildings and industrial structures is tested in cyclic bending combined with axial compression. The positioning of the steel ducts along the sides of the column cross-section allows for using traditional reinforcement cages for the column, with longitudinal bars at both mid-side and corners of the cross-section. Splice length and amount of transverse reinforcement along the splice are defined based on Eurocode 2 provisions for laps of reinforcing bars. A total of 19 loading cycles are carried out, achieving a drift of 5.3% in correspondence of a degradation of 15% of the peak resistance. The shear slip measured at the column-foundation interface results to be smaller than 5% of the deflection. Conversely, to predict accurately the test results, the slip of the projecting bars within their ducts cannot be neglected. It is proposed to take account of this slip by introducing an apparent strain. For the tested specimen, the apparent strain turns out to be equal to the yield strain of the reinforcement. A comparison with a monotonic bending test, previously conducted on the same connection, shows a strongly smaller deformability when the loading protocol is cyclic. Hysteretic energy and drift ductility for the proposed connection are close to those concerning a cast-in-place specimen of comparable capacity, which was described in a recent paper. The test results show an over-strength of 1.4 and a gain in ductility of 1.8 compared with the design values of bending resistance and curvature ductility computed for the cross-section at the column-foundation interface

    In-plane bending of Timoshenko beams in bilateral frictionless contact with an elastic half-space using a coupled FE-BIE method

    No full text
    Making use of a mixed variational formulation including the Green function of the substrate, a finite element model is derived for the static analysis of Timoshenko beams in bilateral frictionless contact with an elastic half-space. Numerical results are obtained by adopting locking-free Hermite polynomials for the Timoshenko beam and piecewise constant reaction over the soil. Foundation beams loaded by forces and couples at the midspan illustrate accuracy and convergence properties of the proposed formulation

    Beam theory for strongly orthotropic materials

    No full text
    This paper presents a displacement-based model for orthotropic beams under plane linear elasticity based on the only kinematic assumption of transverse inextensibility. Any given axial and transverse loading as well as boundary conditions at the beam ends are considered. The solution is decomposed into the principal and the residual part (corresponding to the interior and the boundary problems) which are obtained by series expansions of polynomial functions and eigenfunctions, respectively. It is proved that the proposed one-dimensional theory gives both interior and boundary exact two-dimensional elasticity solutions for strongly orthotropic materials, i.e. for ratio between shear modulus and axial Young modulus approaching zero. For isotropic and orthotropic materials the accuracy of the beam model is also analysed and compared with that of other theories. In particular, the complementary energy error of the interior solution with respect to two-dimensional elasticity is evaluated, the asymptotic estimate of the characteristic decay length of end effects given in Choi and Horgan [J. Appl. Mech. ASME, 44, 424-430 (1977)] by two-dimensional analysis is reobtained and the range of validity of boundary solution is discussed. The numerical results presented agree very well with exact and finite element solutions even in the neighbourhood of clamped cross-sections, where the solution is mainly governed by the boundary problem

    Ripristino della fruibilità post-sismica di edifici prefabbricati dell’Università di Ferrara

    No full text
    La memoria riporta una panoramica degli interventi realizzati dopo la sequenza sismica emiliana del maggio 2012 negli edifici a struttura prefabbricata in c.a. ubicati presso il Polo Scientifico-Tecnologico dell’Università di Ferrara. Gli edifici sono sorti tra il 1996 e il 2002, quando Ferrara non rientrava in zona sismica. Essi hanno pertanto i tegoli di copertura e le travi in semplice appoggio rispettivamente su travi e pilastri, senza alcun dispositivo di ritegno. Non essendo lecito affidare unicamente alla forza d’attrito la resistenza nei confronti delle azioni sismiche, gli edifici sono stati dichiarati inagibili subito dopo la sequenza, pur non avendo riportato Danni significativi. Allo scopo di consentirne una rapida riapertura sono state progettate opportune connessioni metalliche. Le forze di progetto da affidare alle connessioni sono state determinate tramite modellazioni agli elementi finiti degli edifici e analisi dinamiche con spettro di risposta
    • …
    corecore