Crystal experiments on efficient beam extraction
Silicon crystal was channeling and extracting 70-GeV protons from the U-70
accelerator with efficiency of 85.3+-2.8% as measured for a beam of 10^12
protons directed towards crystals of 2 mm length in spills of 1-2 s duration.
The experimental data follow very well the prediction of Monte Carlo
simulations. This success is important to devise a more efficient use of the
U-70 accelerator in Protvino and provides a crucial support for implementation
of crystal-assisted collimation of gold ion beam in RHIC and slow extraction
from AGS onto E952, now in preparation at Brookhaven Nat'l Lab. Future
applications, spanning in the energy from sub-GeV (medical) to order of 1 GeV
(scraping in the SNS, extraction from COSY) to order of 1 TeV and beyond
(scraping in the Tevatron, LHC, VLHC), can benefit from these studies.Comment: 12pp. Presented at 19-th Intern. Conference on Atomic Collisions in
Solids (ICACS-19: Paris, July 29 - August 3, 2001
Progress in crystal extraction and collimation
Recent IHEP Protvino experiments show efficiencies of crystal-assisted slow
extraction and collimation of 85.3+-2.8%, at the intensities of the channeled
beam on the order of 10^12 proton per spill of 2 s duration. The obtained
experimental data well follows the theory predictions. We compare the
measurements against theory and outline the theoretical potential for further
improvement in the efficiency of the technique. This success is important for
the efficient use of IHEP accelerator and for implementation of
crystal-assisted collimation at RHIC and slow extraction from AGS onto E952,
now in preparation. Future applications, spanning in the energy from order of 1
GeV (scraping in SNS, slow extraction from COSY and medical accelerators) to
order of 1 TeV and beyond (scraping in Tevatron, LHC, VLHC), can benefit from
these studies.Comment: 7pp. Presented at HEACC 2001 (Tsukuba, March 25-30
The Investigations Of Beam Extraction And Collimation At U-70 Proton Synchrotron Of IHEP By Using Short Silicon Crystals
The new results of using short (2-4mm) bent crystals for extraction and
collimation of proton beam at IHEP 70 Gev proton synchrotron are reported. A
broad range of energies from 6 to 65 GeV has been studied in the same crystal
collimation set-up. The efficiency of extraction more than 85% and intensity
more than 10E12 were obtained by using crystal with the length 2-mm and the
angle 1 mrad. The new regime of extraction is applied now at the accelerator to
deliver the beam for different experimental setups within the range of
intensity 10E7-10E12ppp.Comment: Presented at EPAC 2002 (Paris, June 3-7), 3p
An Integrated Circuit for Signal Processing of the AMS RICH Photmultipliers Tubes
An analog integrated circuit has been designed, in a BiCMOS 0.8 micron
technology, for the feasability study of the signal processing of the AMS RICH
photomultiplier tubes. This low power, three channel gated integrator includes
its own gate and no external analog delay is requiered. It processes PMT pulses
over a dynamic range of more than 100. A logic output that indicates whether
the analog charge has to be considered is provided. This gated integrator is
used with a compact DSP based acquisition system in a 132 channels RICH
prototype. The charge calibration of each channel is carried out using a LED.
The pedestal measurement is performed on activation of a dedicated input. The
noise contribution study of the input RC network and amplifiers is presented.Comment: IEEE symp. on Nucl. Sci. and Med. Imaging, Toront