203 research outputs found

    Journal of Clinical Monitoring and Computing 2019 end of year summary:monitoring tissue oxygenation and perfusion and its autoregulation

    Get PDF
    Tissue perfusion monitoring is increasingly being employed clinically in a non-invasive fashion. In this end-of-year summary of the Journal of Clinical Monitoring and Computing, we take a closer look at the papers published recently on this subject in the journal. Most of these papers focus on monitoring cerebral perfusion (and associated hemodynamics), using either transcranial doppler measurements or near-infrared spectroscopy. Given the importance of cerebral autoregulation in the analyses performed in most of the studies discussed here, this end-of-year summary also includes a short description of cerebral hemodynamic physiology and its autoregulation. Finally, we review articles on somatic tissue oxygenation and its possible association with outcome

    The contemporary pulmonary artery catheter. Part 1:placement and waveform analysis

    Get PDF
    Nowadays, the classical pulmonary artery catheter (PAC) has an almost 50-year-old history of its clinical use for hemodynamic monitoring. In recent years, the PAC evolved from a device that enabled intermittent cardiac output measurements in combination with static pressures to a monitoring tool that provides continuous data on cardiac output, oxygen supply and-demand balance, as well as right ventricular (RV) performance. In this review, which consists of two parts, we will introduce the difference between intermittent pulmonary artery thermodilution using cold bolus injections, and the contemporary PAC enabling continuous measurements by using a thermal filament which at random heats up the blood. In this first part, the insertion techniques, interpretation of waveforms of the PAC, the interaction of waveforms with the respiratory cycle and airway pressure as well as pitfalls in waveform analysis are discussed. The second part will cover the measurements of the contemporary PAC including measurement of continuous cardiac output, RV ejection fraction, end-diastolic volume index, and mixed venous oxygen saturation. Limitations of all of these measurements will be highlighted there as well. We conclude that thorough understanding of measurements obtained from the PAC are the first step in successful application of the PAC in daily clinical practice

    The contemporary pulmonary artery catheter. Part 2:measurements, limitations, and clinical applications

    Get PDF
    Nowadays, the classical pulmonary artery catheter (PAC) has an almost 50-year-old history of its clinical use for hemodynamic monitoring. In recent years, the PAC evolved from a device that enabled intermittent cardiac output measurements in combination with static pressures to a monitoring tool that provides continuous data on cardiac output, oxygen supply and-demand balance, as well as right ventricular performance. In this review, which consists of two parts, we will introduce the difference between intermittent pulmonary artery thermodilution using bolus injections, and the contemporary PAC enabling continuous measurements by using a thermal filament which heats up the blood. In this second part, we will discuss in detail the measurements of the contemporary PAC, including continuous cardiac output measurement, right ventricular ejection fraction, end-diastolic volume index, and mixed venous oxygen saturation. Limitations of all of these measurements are highlighted as well. We conclude that thorough understanding of measurements obtained from the PAC is the first step in successful application of the PAC in daily clinical practice

    Existing fluid responsiveness studies using the mini-fluid challenge may be misleading:Methodological considerations and simulations

    Get PDF
    BACKGROUND: The mini-fluid challenge (MFC) is a clinical concept of predicting fluid responsiveness by rapidly infusing a small amount of intravenous fluids, typically 100 ml, and systematically assessing its haemodynamic effect. The MFC method is meant to predict if a patient will respond to a subsequent, larger fluid challenge, typically another 400 ml, with a significant increase in stroke volume. METHODS: We critically evaluated the general methodology of MFC studies, with statistical considerations, secondary analysis of an existing study, and simulations. RESULTS: Secondary analysis of an existing study showed that the MFC could predict the total fluid response (MFC + 400 ml) with an area under the receiver operator characteristics curve (AUROC) of 0.92, but that the prediction was worse than random for the response to the remaining 400 ml (AUROC = 0.33). In a null simulation with no response to both the MFC and the subsequent fluid challenge, the commonly used analysis could predict fluid responsiveness with an AUROC of 0.73. CONCLUSION: Many existing MFC studies are likely overestimating the classification accuracy of the MFC. This should be considered before adopting the MFC into clinical practice. A better study design includes a second, independent measurement of stroke volume after the MFC. This measurement serves as reference for the response to the subsequent fluid challenge

    The Reduction in Right Ventricular Longitudinal Contraction Parameters Is Not Accompanied by a Reduction in General Right Ventricular Performance During Aortic Valve Replacement:An Explorative Study

    Get PDF
    Objective: The aim of the present study was to identify whether the decrease of longitudinal parameters after cardiothoracic surgery (ie, tricuspid annular systolic plane excursion [TAPSE] and systolic excursion velocity [S']) is accompanied by a reduction in global right ventricular (RV) performance. Design: Prospective, observational study. Setting: Single-center explorative study in a tertiary teaching hospital. Participants: The study comprised 20 patients who underwent aortic valve replacement with or without coronary artery bypass grafting. Interventions: During cardiac surgery, simultaneous measurements of RV function were performed with a pulmonary artery catheter and transesophageal echocardiography. Measurements and Main Results: TAPSE and S’ were reduced significantly directly after surgery compared with the time before surgery (TAPSE from 20.8 [16.6-23.4] mm to 9.1 [5.6-15.5] mm; p < 0.001 and S’ from 8.7 [7.9-10.7] cm/s to 7.2 [5.7-8.6] cm/s; p = 0.041). However, the reduction in TAPSE and S’ was not accompanied by a reduction in RV performance, as assessed with the TEE-derived myocardial performance index (MPI) and pulmonary artery catheter–derived RV ejection fraction (RVEF). Both remained statistically unaltered before and after the procedure (MPI from 0.52 [0.43-0.58] to 0.50 [0.42-0.88]; p = 0.278 and RVEF from 27% [22%-32%] to 26% [22%-28%]; p = 0.294). Conclusions: In the direct postoperative phase, the reduction of echocardiographic parameters of longitudinal RV contractility (TAPSE and S’) were not accompanied by a reduction in global RV performance, expressed as MPI and RVEF. Solely relying on a single RV parameter as a marker for global RV performance may not be adequate to assess the complex adaptation of the right ventricle to aortic valve replacement

    The effect of compliance with a perioperative goal-directed therapy protocol on outcomes after high-risk surgery:a before-after study

    Get PDF
    Perioperative goal-directed therapy is considered to improve patient outcomes after high-risk surgery. The association of compliance with perioperative goal-directed therapy protocols and postoperative outcomes is unclear. The purpose of this study is to determine the effect of protocol compliance on postoperative outcomes following high-risk surgery, after implementation of a perioperative goal-directed therapy protocol. Through a before-after study design, patients undergoing elective high-risk surgery before (before-group) and after implementation of a perioperative goal-directed therapy protocol (after-group) were included. Perioperative goal-directed therapy in the after-group consisted of optimized stroke volume variation or stroke volume index and optimized cardiac index. Additionally, the association of protocol compliance with postoperative complications when using perioperative goal-directed therapy was assessed. High protocol compliance was defined as >= 85% of the procedure time spent within the individual targets. The difference in complications during the first 30 postoperative days before and after implementation of the protocol was assessed. In the before-group, 214 patients were included and 193 patients in the after-group. The number of complications was higher in the before-group compared to the after-group (n = 414 vs. 282; p = 0.031). In the after-group, patients with high protocol compliance for stroke volume variation or stroke volume index had less complications compared to patients with low protocol compliance for stroke volume variation or stroke volume index (n = 187 vs. 90; p = 0.01). Protocol compliance by the attending clinicians is essential and should be monitored to facilitate an improvement in postoperative outcomes desired by the implementation of perioperative goal-directed therapy protocols
    • …
    corecore