2 research outputs found

    ВСрмодинамичСскиС Ρ€Π΅ΠΆΠΈΠΌΡ‹ Ρ€Π΅ΠΊΡƒΠΏΠ΅Ρ€Π°Ρ‚ΠΈΠ²Π½ΠΎΠ³ΠΎ Ρ‚Π΅ΠΏΠ»ΠΎΠΎΠ±ΠΌΠ΅Π½Π½ΠΈΠΊΠ°-ΡƒΡ‚ΠΈΠ»ΠΈΠ·Π°Ρ‚ΠΎΡ€Π° Π² ΠΏΡ€ΠΈΡ‚ΠΎΡ‡Π½ΠΎ-вытяТной вСнтиляционной установкС ΠΌΠ°Π»ΠΎΠΉ ΠΏΡ€ΠΎΠΈΠ·Π²ΠΎΠ΄ΠΈΡ‚Π΅Π»ΡŒΠ½ΠΎΡΡ‚ΠΈ

    Get PDF
    The increase in the thermal protection level of the existing buildings enclosing structures, due to the need to comply with the current norms of building heat engineering requirements, leads to increasing in the part of heat losses in the thermal balance of a building due to infiltration and exhaust ventilation operation. After exhaustion of the possibilities for the implementation of technical measures to reduce energy costs by changing in volumetric planning solutions and insulating building envelopes further decreasing heat consumption level should be associated with the use of the secondary and renewable resources potential. The paper presents the results of assessing the technical and economic feasibility of using the exhaust air thermal potential for heating the supply air in the forced supply-and-exhaust ventilation system of a building taking as a low-capacity unit as an example. For a counterflow air-to-air recuperative type heat utilizer finned with ribbed heat pipes in the form of a plurality of continuous sheets, the influence of changes in the physical properties of the exhaust air during the phase transition of the water vapor contained in it into a liquid state on the heat exchanger-utilizer performance and characteristics of its efficiency has been established. The conditions of heat exchange are determined (without condensate, with condensate in the part of the heat exchanger-utilizer, with condensate in the entire heat exchanger-utilizer and with the risk of icing) in the supply air temperature range from (–26) to (+8) Β°C for three variants of its operation with a balance of the nominal amount of exhaust and supply air and with two variants of imbalance. Variants with imbalances have been investigated in order to find possible combinations of supply and exhaust air temperatures, at which there would be no phase transition of water vapor in the exhaust air flow to the liquid state in the entire volume of the heat utilizer, which would eliminate the need for measures to collect and remove condensate and preventing it from freezing.НаращиваниС уровня Ρ‚Π΅ΠΏΠ»ΠΎΠ²ΠΎΠΉ Π·Π°Ρ‰ΠΈΡ‚Ρ‹ ΠΎΠ³Ρ€Π°ΠΆΠ΄Π°ΡŽΡ‰ΠΈΡ… конструкций ΡΡƒΡ‰Π΅ΡΡ‚Π²ΡƒΡŽΡ‰ΠΈΡ… Π·Π΄Π°Π½ΠΈΠΉ, обусловлСнноС Π½Π΅ΠΎΠ±Ρ…ΠΎΠ΄ΠΈΠΌΠΎΡΡ‚ΡŒΡŽ соблюдСния Ρ‚Ρ€Π΅Π±ΠΎΠ²Π°Π½ΠΈΠΉ Π΄Π΅ΠΉΡΡ‚Π²ΡƒΡŽΡ‰ΠΈΡ… Π½ΠΎΡ€ΠΌ ΡΡ‚Ρ€ΠΎΠΈΡ‚Π΅Π»ΡŒΠ½ΠΎΠΉ Ρ‚Π΅ΠΏΠ»ΠΎΡ‚Π΅Ρ…Π½ΠΈΠΊΠΈ, ΠΏΡ€ΠΈΠ²ΠΎΠ΄ΠΈΡ‚ ΠΊ ΡƒΠ²Π΅Π»ΠΈΡ‡Π΅Π½ΠΈΡŽ Π΄ΠΎΠ»ΠΈ Ρ‚Π΅ΠΏΠ»ΠΎΠ²Ρ‹Ρ… ΠΏΠΎΡ‚Π΅Ρ€ΡŒ Π·Π° счСт ΠΈΠ½Ρ„ΠΈΠ»ΡŒΡ‚Ρ€Π°Ρ†ΠΈΠΈ ΠΈ Ρ€Π°Π±ΠΎΡ‚Ρ‹ вытяТной вСнтиляции Π² Ρ‚Π΅ΠΏΠ»ΠΎΠ²ΠΎΠΌ балансС здания. ПослС исчСрпания возмоТностСй Ρ€Π΅Π°Π»ΠΈΠ·Π°Ρ†ΠΈΠΈ тСхничСских мСроприятий для ΡƒΠΌΠ΅Π½ΡŒΡˆΠ΅Π½ΠΈΡ энСргозатрат Π·Π° счСт измСнСния объСмно-ΠΏΠ»Π°Π½ΠΈΡ€ΠΎΠ²ΠΎΡ‡Π½Ρ‹Ρ… Ρ€Π΅ΡˆΠ΅Π½ΠΈΠΉ ΠΈ утСплСния ΠΎΠ³Ρ€Π°ΠΆΠ΄Π°ΡŽΡ‰ΠΈΡ… конструкций Π·Π΄Π°Π½ΠΈΠΉ дальнСйшСС сниТСниС уровня тСплопотрСблСния Π΄ΠΎΠ»ΠΆΠ½ΠΎ Π±Ρ‹Ρ‚ΡŒ связано с ΠΏΡ€ΠΈΠΌΠ΅Π½Π΅Π½ΠΈΠ΅ΠΌ ΠΏΠΎΡ‚Π΅Π½Ρ†ΠΈΠ°Π»Π° Π²Ρ‚ΠΎΡ€ΠΈΡ‡Π½Ρ‹Ρ… ΠΈ возобновляСмых рСсурсов. Π’ ΡΡ‚Π°Ρ‚ΡŒΠ΅ ΠΏΡ€ΠΈΠ²Π΅Π΄Π΅Π½Ρ‹ Ρ€Π΅Π·ΡƒΠ»ΡŒΡ‚Π°Ρ‚Ρ‹ ΠΎΡ†Π΅Π½ΠΊΠΈ Ρ‚Π΅Ρ…Π½ΠΈΠΊΠΎ-экономичСской цСлСсообразности использования Ρ‚Π΅ΠΏΠ»ΠΎΠ²ΠΎΠ³ΠΎ ΠΏΠΎΡ‚Π΅Π½Ρ†ΠΈΠ°Π»Π° удаляСмого Π²ΠΎΠ·Π΄ΡƒΡ…Π° для Π½Π°Π³Ρ€Π΅Π²Π° ΠΏΡ€ΠΈΡ‚ΠΎΡ‡Π½ΠΎΠ³ΠΎ Π²ΠΎΠ·Π΄ΡƒΡ…Π° Π² систСмС ΠΏΡ€ΠΈΠ½ΡƒΠ΄ΠΈΡ‚Π΅Π»ΡŒΠ½ΠΎΠΉ ΠΏΡ€ΠΈΡ‚ΠΎΡ‡Π½ΠΎ-вытяТной вСнтиляции здания Π½Π° ΠΏΡ€ΠΈΠΌΠ΅Ρ€Π΅ установки ΠΌΠ°Π»ΠΎΠΉ ΠΏΡ€ΠΎΠΈΠ·Π²ΠΎΠ΄ΠΈΡ‚Π΅Π»ΡŒΠ½ΠΎΡΡ‚ΠΈ. Для ΠΏΡ€ΠΎΡ‚ΠΈΠ²ΠΎΡ‚ΠΎΡ‡Π½ΠΎΠ³ΠΎ Π²ΠΎΠ·Π΄ΡƒΡ…ΠΎ-Π²ΠΎΠ·Π΄ΡƒΡˆΠ½ΠΎΠ³ΠΎ Ρ‚Π΅ΠΏΠ»ΠΎΡƒΡ‚ΠΈΠ»ΠΈΠ·Π°Ρ‚ΠΎΡ€Π° Ρ€Π΅ΠΊΡƒΠΏΠ΅Ρ€Π°Ρ‚ΠΈΠ²Π½ΠΎΠ³ΠΎ Ρ‚ΠΈΠΏΠ° с ΠΎΡ€Π΅Π±Ρ€Π΅Π½ΠΈΠ΅ΠΌ Ρ‚Π΅ΠΏΠ»ΠΎΠ²Ρ‹Ρ… Ρ‚Ρ€ΡƒΠ±ΠΎΠΊ Π² Π²ΠΈΠ΄Π΅ мноТСства ΡΠΏΠ»ΠΎΡˆΠ½Ρ‹Ρ… листов установлСно влияниС ΠΈΠ·ΠΌΠ΅Π½Π΅Π½ΠΈΠΉ физичСских свойств удаляСмого Π²ΠΎΠ·Π΄ΡƒΡ…Π° ΠΏΡ€ΠΈ Ρ„Π°Π·ΠΎΠ²ΠΎΠΌ ΠΏΠ΅Ρ€Π΅Ρ…ΠΎΠ΄Π΅ водяного ΠΏΠ°Ρ€Π°, содСрТащСгося Π² Π½Π΅ΠΌ, Π² ΠΆΠΈΠ΄ΠΊΠΎΠ΅ состояниС Π½Π° Ρ‚Π΅ΠΏΠ»ΠΎΠ²ΡƒΡŽ ΠΏΡ€ΠΎΠΈΠ·Π²ΠΎΠ΄ΠΈΡ‚Π΅Π»ΡŒΠ½ΠΎΡΡ‚ΡŒ Ρ‚Π΅ΠΏΠ»ΠΎΡƒΡ‚ΠΈΠ»ΠΈΠ·Π°Ρ‚ΠΎΡ€Π° ΠΈ характСристики Π΅Π³ΠΎ эффСктивности. ΠžΠΏΡ€Π΅Π΄Π΅Π»Π΅Π½Ρ‹ условия Ρ‚Π΅ΠΏΠ»ΠΎΠΎΠ±ΠΌΠ΅Π½Π° (Π±Π΅Π· выпадСния кондСнсата, с Π²Ρ‹ΠΏΠ°Π΄Π΅Π½ΠΈΠ΅ΠΌ кондСнсата Π² части Ρ‚Π΅ΠΏΠ»ΠΎΡƒΡ‚ΠΈΠ»ΠΈΠ·Π°Ρ‚ΠΎΡ€Π°, с Π²Ρ‹ΠΏΠ°Π΄Π΅Π½ΠΈΠ΅ΠΌ кондСнсата Π²ΠΎ всСм Ρ‚Π΅ΠΏΠ»ΠΎΡƒΡ‚ΠΈΠ»ΠΈΠ·Π°Ρ‚ΠΎΡ€Π΅ ΠΈ с ΠΎΠΏΠ°ΡΠ½ΠΎΡΡ‚ΡŒΡŽ облСдСнСния) Π² Π΄ΠΈΠ°ΠΏΠ°Π·ΠΎΠ½Π΅ Ρ‚Π΅ΠΌΠΏΠ΅Ρ€Π°Ρ‚ΡƒΡ€ ΠΏΡ€ΠΈΡ‚ΠΎΡ‡Π½ΠΎΠ³ΠΎ Π²ΠΎΠ·Π΄ΡƒΡ…Π° (–26)–(+8) ΒΊΠ‘ для Ρ‚Ρ€Π΅Ρ… Π²Π°Ρ€ΠΈΠ°Π½Ρ‚ΠΎΠ² Π΅Π³ΠΎ Ρ€Π°Π±ΠΎΡ‚Ρ‹ – ΠΏΡ€ΠΈ балансС номинального количСства удаляСмого ΠΈ ΠΏΡ€ΠΈΡ‚ΠΎΡ‡Π½ΠΎΠ³ΠΎ Π²ΠΎΠ·Π΄ΡƒΡ…Π° ΠΈ ΠΏΡ€ΠΈ Π΄Π²ΡƒΡ… Π²Π°Ρ€ΠΈΠ°Π½Ρ‚Π°Ρ… дисбаланса. Π’Π°Ρ€ΠΈΠ°Π½Ρ‚Ρ‹ с дисбалансами исслСдованы Π² цСлях поиска Π²ΠΎΠ·ΠΌΠΎΠΆΠ½Ρ‹Ρ… сочСтаний Ρ‚Π΅ΠΌΠΏΠ΅Ρ€Π°Ρ‚ΡƒΡ€ ΠΏΡ€ΠΈΡ‚ΠΎΡ‡Π½ΠΎΠ³ΠΎ ΠΈ удаляСмого Π²ΠΎΠ·Π΄ΡƒΡ…Π°, ΠΏΡ€ΠΈ ΠΊΠΎΡ‚ΠΎΡ€Ρ‹Ρ… Π²ΠΎ всСм объСмС Ρ‚Π΅ΠΏΠ»ΠΎΡƒΡ‚ΠΈΠ»ΠΈΠ·Π°Ρ‚ΠΎΡ€Π° Π½Π΅ происходило Π±Ρ‹ Ρ„Π°Π·ΠΎΠ²ΠΎΠ³ΠΎ ΠΏΠ΅Ρ€Π΅Ρ…ΠΎΠ΄Π° водяного ΠΏΠ°Ρ€Π° Π² ΠΏΠΎΡ‚ΠΎΠΊΠ΅ удаляСмого Π²ΠΎΠ·Π΄ΡƒΡ…Π° Π² ΠΆΠΈΠ΄ΠΊΠΎΠ΅ состояниС, Ρ‡Ρ‚ΠΎ ΠΈΡΠΊΠ»ΡŽΡ‡ΠΈΠ»ΠΎ Π±Ρ‹ Π½Π΅ΠΎΠ±Ρ…ΠΎΠ΄ΠΈΠΌΠΎΡΡ‚ΡŒ провСдСния мСроприятий ΠΏΠΎ сбору ΠΈ ΠΎΡ‚Π²ΠΎΠ΄Ρƒ кондСнсата ΠΈ ΠΏΡ€Π΅Π΄ΠΎΡ‚Π²Ρ€Π°Ρ‰Π΅Π½ΠΈΡŽ Π΅Π³ΠΎ замСрзания

    ΠžΡ†Π΅Π½ΠΊΠ° эффСктивности ΡΠ½Π΅Ρ€Π³ΠΎΡΠ±Π΅Ρ€Π΅Π³Π°ΡŽΡ‰Π΅ΠΉ систСмы ΠΎΡ€Π³Π°Π½ΠΈΠ·ΠΎΠ²Π°Π½Π½ΠΎΠΉ ΠΏΡ€ΠΈΡ‚ΠΎΡ‡Π½ΠΎ-вытяТной вСнтиляции для многоэтаТных Π·Π΄Π°Π½ΠΈΠΉ с Π½ΠΈΠ·ΠΊΠΈΠΌ ΡƒΡ€ΠΎΠ²Π½Π΅ΠΌ Ρ‚Π΅ΠΏΠ»ΠΎΠ²ΠΎΠΉ Π·Π°Ρ‰ΠΈΡ‚Ρ‹

    Get PDF
    By usage of the technical and economic calculation method developed by the authors for installations with recuperative-type heat exchangers, the operational modes of the centralized supply and exhaust system of organized ventilation, in which the supplying air is heated by the solar radiation heat and the heat of the air removed from the premises, have been investigated in the paper. The paper presents results of the thermal and economic efficiency assessment of such ventilation system for multi-storey buildings. A comparison of the thermal energy consumption for the needs of heating and ventilation through the use of the proposed ventilation system has been made for two variants of buildings – with the thermal protection level of enclosing structures that meets modern regulatory requirements (buildings with heat consumption up Β to 130 kWΓ—h/(m2Γ—year)), and for a building similar in terms of planning structure, but with enclosing structures, the insulation level of which corresponds to buildings built before 1993 (buildings with heat consumption up to 260 kWΓ—h/(m2Γ—year)). Β The temperature conditions have been determined under which it becomes necessary to turn on the operation of devices Β for additional (peak) heating of the supply air, when the thermal potential of solar radiation and secondary energy resources Β isΒ  insufficient to provide the calculated temperature of the supply air. For the ventilation system under consideration, it has been Β established that the thermal resistance of the building envelope influences the indicators of the thermodynamic and economic efficiency of the proposed solution. The climatic conditions under which the utilization of the exhaust air heat in the proposed ventilation system is technically justified and economically expedient have been determined. The results of the researchΒ Π‘ использованиСм Ρ€Π°Π·Ρ€Π°Π±ΠΎΡ‚Π°Π½Π½ΠΎΠ³ΠΎ Π°Π²Ρ‚ΠΎΡ€Π°ΠΌΠΈ ΠΌΠ΅Ρ‚ΠΎΠ΄Π° Ρ‚Π΅Ρ…Π½ΠΈΠΊΠΎ-экономичСского расчСта установок с Ρ‚Π΅ΠΏΠ»ΠΎΠΎΠ±ΠΌΠ΅Π½Π½Ρ‹ΠΌΠΈ Π°ΠΏΠΏΠ°Ρ€Π°Ρ‚Π°ΠΌΠΈ Ρ€Π΅ΠΊΡƒΠΏΠ΅Ρ€Π°Ρ‚ΠΈΠ²Π½ΠΎΠ³ΠΎ Ρ‚ΠΈΠΏΠ° исслСдованы Ρ€Π΅ΠΆΠΈΠΌΡ‹ эксплуатации Ρ†Π΅Π½Ρ‚Ρ€Π°Π»ΠΈΠ·ΠΎΠ²Π°Π½Π½ΠΎΠΉ ΠΏΡ€ΠΈΡ‚ΠΎΡ‡Π½ΠΎ-вытяТной систСмы ΠΎΡ€Π³Π°Π½ΠΈΠ·ΠΎΠ²Π°Π½Π½ΠΎΠΉ вСнтиляции, Π² ΠΊΠΎΡ‚ΠΎΡ€ΠΎΠΉ ΠΏΠΎΠ΄ΠΎΠ³Ρ€Π΅Π² ΠΏΡ€ΠΈΡ‚ΠΎΡ‡Π½ΠΎΠ³ΠΎ Π²ΠΎΠ·Π΄ΡƒΡ…Π° осущСствляСтся Π·Π° счСт Β Ρ‚Π΅ΠΏΠ»ΠΎΡ‚Ρ‹ солнСчного излучСния ΠΈ Ρ‚Π΅ΠΏΠ»ΠΎΡ‚Ρ‹ удаляСмого ΠΈΠ· ΠΏΠΎΠΌΠ΅Ρ‰Π΅Π½ΠΈΠΉ Π²ΠΎΠ·Π΄ΡƒΡ…Π°. ΠŸΡ€Π΅Π΄ΡΡ‚Π°Π²Π»Π΅Π½Ρ‹ Ρ€Π΅Π·ΡƒΠ»ΡŒΡ‚Π°Ρ‚Ρ‹ ΠΎΡ†Π΅Π½ΠΊΠΈ Ρ‚Π΅ΠΏΠ»ΠΎΠ²ΠΎΠΉ ΠΈ экономичСской эффСктивности Ρ‚Π°ΠΊΠΎΠΉ систСмы вСнтиляции для многоэтаТных Π·Π΄Π°Π½ΠΈΠΉ. Π’Ρ‹ΠΏΠΎΠ»Π½Π΅Π½ΠΎ сравнСниС расходов Ρ‚Π΅ΠΏΠ»ΠΎΠ²ΠΎΠΉ энСргии Π½Π° Π½ΡƒΠΆΠ΄Ρ‹ отоплСния ΠΈ вСнтиляции Π·Π° счСт примСнСния ΠΏΡ€Π΅Π΄Π»Π°Π³Π°Π΅ΠΌΠΎΠΉ систСмы вСнтиляции для Π΄Π²ΡƒΡ… Π²Π°Ρ€ΠΈΠ°Π½Ρ‚ΠΎΠ² Π·Π΄Π°Π½ΠΈΠΉ – с ΡƒΡ€ΠΎΠ²Π½Π΅ΠΌ Ρ‚Π΅ΠΏΠ»ΠΎΠ²ΠΎΠΉ Π·Π°Ρ‰ΠΈΡ‚Ρ‹ ΠΎΠ³Ρ€Π°ΠΆΠ΄Π°ΡŽΡ‰ΠΈΡ… конструкций, ΠΎΡ‚Π²Π΅Ρ‡Π°ΡŽΡ‰ΠΈΠΌ соврСмСнным Π½ΠΎΡ€ΠΌΠ°Ρ‚ΠΈΠ²Π½Ρ‹ΠΌ трСбованиям (здания с Ρ‚Π΅ΠΏΠ»ΠΎΠΏΠΎΡ‚Ρ€Π΅Π±Π»Π΅Π½ΠΈΠ΅ΠΌ Π΄ΠΎ 130 ΠΊΠ’Ρ‚Γ—Ρ‡/(ΠΌ2Γ—Π³ΠΎΠ΄)), ΠΈ для Π°Π½Π°Π»ΠΎΠ³ΠΈΡ‡Π½ΠΎΠ³ΠΎ ΠΏΠΎ ΠΏΠ»Π°Π½ΠΈΡ€ΠΎΠ²ΠΎΡ‡Π½ΠΎΠΉ структурС здания, Π½ΠΎ с ΠΎΠ³Ρ€Π°ΠΆΠ΄Π°ΡŽΡ‰ΠΈΠΌΠΈ конструкциями, ΡƒΡ€ΠΎΠ²Π΅Π½ΡŒ утСплСния ΠΊΠΎΡ‚ΠΎΡ€Ρ‹Ρ… соотвСтствуСт зданиям  постройки Π΄ΠΎ 1993 Π³. (здания с Ρ‚Π΅ΠΏΠ»ΠΎΠΏΠΎΡ‚Ρ€Π΅Π±Π»Π΅Π½ΠΈΠ΅ΠΌ Π΄ΠΎ 260 ΠΊΠ’Ρ‚Γ—Ρ‡/(ΠΌ2Γ—Π³ΠΎΠ΄)). ΠžΠΏΡ€Π΅Π΄Π΅Π»Π΅Π½Ρ‹ Ρ‚Π΅ΠΌΠΏΠ΅Ρ€Π°Ρ‚ΡƒΡ€Π½Ρ‹Π΅ условия, ΠΏΡ€ΠΈ ΠΊΠΎΡ‚ΠΎΡ€Ρ‹Ρ… Π²ΠΎΠ·Π½ΠΈΠΊΠ°Π΅Ρ‚ Π½Π΅ΠΎΠ±Ρ…ΠΎΠ΄ΠΈΠΌΠΎΡΡ‚ΡŒ Π²ΠΊΠ»ΡŽΡ‡Π΅Π½ΠΈΡ Π² Ρ€Π°Π±ΠΎΡ‚Ρƒ устройств Π΄ΠΎΠΏΠΎΠ»Π½ΠΈΡ‚Π΅Π»ΡŒΠ½ΠΎΠ³ΠΎ (ΠΏΠΈΠΊΠΎΠ²ΠΎΠ³ΠΎ) ΠΏΠΎΠ΄ΠΎΠ³Ρ€Π΅Π²Π° ΠΏΡ€ΠΈΡ‚ΠΎΡ‡Π½ΠΎΠ³ΠΎ Π²ΠΎΠ·Π΄ΡƒΡ…Π°, ΠΊΠΎΠ³Π΄Π° Ρ‚Π΅ΠΏΠ»ΠΎΠ²ΠΎΠΉ ΠΏΠΎΡ‚Π΅Π½Ρ†ΠΈΠ°Π» солнСчного излучСния ΠΈ Π²Ρ‚ΠΎΡ€ΠΈΡ‡Π½Ρ‹Ρ… энСргСтичСских рСсурсов нСдостаточСн для обСспСчСния расчСтной Ρ‚Π΅ΠΌΠΏΠ΅Ρ€Π°Ρ‚ΡƒΡ€Ρ‹ ΠΏΡ€ΠΈΡ‚ΠΎΡ‡Π½ΠΎΠ³ΠΎ Π²ΠΎΠ·Π΄ΡƒΡ…Π°. Для рассматриваСмой систСмы вСнтиляции установлСно Π½Π°Π»ΠΈΡ‡ΠΈΠ΅ влияния тСрмичСских сопротивлСний ΠΎΠ³Ρ€Π°ΠΆΠ΄Π°ΡŽΡ‰ΠΈΡ… конструкций здания Π½Π° ΠΏΠΎΠΊΠ°Π·Π°Ρ‚Π΅Π»ΠΈ тСрмодинамичСской ΠΈ экономичСской эффСктивности ΠΏΡ€Π΅Π΄Π»Π°Π³Π°Π΅ΠΌΠΎΠ³ΠΎ Ρ€Π΅ΡˆΠ΅Π½ΠΈΡ. ΠžΠΏΡ€Π΅Π΄Π΅Π»Π΅Π½Ρ‹ климатичСскиС условия, ΠΏΡ€ΠΈ ΠΊΠΎΡ‚ΠΎΡ€Ρ‹Ρ… утилизация Ρ‚Π΅ΠΏΠ»ΠΎΡ‚Ρ‹ удаляСмого Π²ΠΎΠ·Π΄ΡƒΡ…Π° Π² систСмС вСнтиляции тСхничСски ΠΎΠΏΡ€Π°Π²Π΄Π°Π½Π° ΠΈ экономичСски цСлСсообразна. Β Π Π΅Π·ΡƒΠ»ΡŒΡ‚Π°Ρ‚Ρ‹ Π²Ρ‹ΠΏΠΎΠ»Π½Π΅Π½Π½Ρ‹Ρ… исслСдований ΠΌΠΎΠ³ΡƒΡ‚ Π±Ρ‹Ρ‚ΡŒ ΠΈΡΠΏΠΎΠ»ΡŒΠ·ΠΎΠ²Π°Π½Ρ‹ ΠΏΡ€ΠΈ ΠΎΠΏΡ€Π΅Π΄Π΅Π»Π΅Π½ΠΈΠΈ ΠΏΡƒΡ‚Π΅ΠΉ Ρ‚Π΅ΠΏΠ»ΠΎΠ²ΠΎΠΉ ΠΌΠΎΠ΄Π΅Ρ€Π½ΠΈΠ·Π°Ρ†ΠΈΠΈ Π·Π΄Π°Π½ΠΈΠΉ с Ρ‚Ρ€Π°Π΄ΠΈΡ†ΠΈΠΎΠ½Π½Ρ‹ΠΌΠΈ систСмами отоплСния ΠΈ вСнтиляци
    corecore