631 research outputs found
The X-Ray Spectral Variability of Mrk 766
Analysis results from ASCA and ROSAT observations of the narrow-line Seyfert
1 galaxy Mrk 766 are reported. In the ASCA observation we observed rapid
variability with a doubling time scale of 1000 seconds. A spectral variability
event was observed in which the spectrum softened and hardened above and below
~1 keV, respectively, as the flux increased. The spectra could be modeled with
5 components: a power law, warm absorber, iron K(alpha) line and soft excess
component flux. The spectral variability resulted from a highly significant
change in the intrinsic photon law index from Gamma ~1.6 to ~2.0, an increase
in the warm absorber ionization, and a marginally significant decrease in the
soft component normalization. A ~100 eV equivalent width narrow iron K(alpha)
line was detected in the high state spectrum. Spectral hardening during flux
increases was observed in three ROSAT observations.
The change in intrinsic photon index and disappearance of the soft excess
component in the ASCA spectra can be explained as a transition from a first
order pair reprocessed spectrum to a pair cascade brought about by a sudden
increase in the injected electron Lorentz factor. The change in the ionization
of the warm absorber, though model dependent, could correspond to the increase
in flux at the oxygen edges resulting from the spectral index change. The ROSAT
spectral variability can be interpreted by variable intensity hard power law
and a relatively nonvarying soft component, possibly primary disk emission.
These results are compared with those reported from other narrow-line Seyfert 1
galaxies.Comment: 29 pages using (AASTeX) aaspp4.sty and 18 Postscript figures. To
appear in the September 1, 1996, issue of The Astrophysical Journa
The variable OVIII Warm Absorber in MCG-6-30-15
We present the results of a 4 day ASCA observation of the Seyfert galaxy
MCG-6-30-15, focussing on the nature of the X-ray absorption by the warm
absorber, characterizd by the K-edges of the intermediately ionized oxygen,
OVII and OVIII. We confirm that the column density of OVIII changes on a
timescale of ~s when the X-ray continuum flux decreases. The
significant anti-correlation of column density with continuum flux gives direct
evidence that the warm absorber is photoionized by the X-ray continuum. From
the timescale of the variation of the OVIII column density, we estimate that it
originates from gas within a radius of about 10^{17}\cm of the central
engine. In contrast, the depth of the OVII edge shows no response to the
continuum flux, which indicates that it originates in gas at larger radii. Our
results strongly suggest that there are two warm absorbing regions; one located
near or within the Broad Line Region, the other associated with the outer
molecular torus, scattering medium or Narrow Line Region.Comment: 8 pages (including figures) uuencoded gziped PS file. Submitted to
Publications of the Astronomical Society of Japa
The Suzaku Observation of NGC 3516: Complex Absorption and the Broad and Narrow Fe K Lines
We present results from a 150 ksec Suzaku observation of the Seyfert 1.5 NGC
3516 in October 2005. The source was in a relatively highly absorbed state. Our
best-fit model is consistent with the presence of a low-ionization absorber
which has a column density near 5 * 10^{22} cm^{-2} and covers most of the
X-ray continuum source (covering fraction 96-100%). A high-ionization absorbing
component, which yields a narrow absorption feature consistent with Fe K XXVI,
is confirmed. A relativistically broadened Fe K alpha line is required in all
fits, even after the complex absorption is taken into account; an additional
partial-covering component is an inadequate substitute for the continuum
curvature associated with the broad Fe line. A narrow Fe K alpha emission line
has a velocity width consistent with the Broad Line Region. The low-ionization
absorber may be responsible for producing the narrow Fe K alpha line, though a
contribution from additional material out of the line of sight is possible. We
include in our model soft band emission lines from He- and H-like ions of N, O,
Ne and Mg, consistent with photo-ionization, though a small contribution from
collisionally-ionized emission is possible.Comment: Accepted for publication in PASJ (Suzaku second special issue). 36
pages, 10 figure
The Infocus Hard X-ray Telescope: Pixellated CZT Detector/Shield Performance and Flight Results
The CZT detector on the Infocus hard X-ray telescope is a pixellated
solid-state device capable of imaging spectroscopy by measuring the position
and energy of each incoming photon. The detector sits at the focal point of an
8m focal length multilayered grazing incidence X-ray mirror which has
significant effective area between 20--40 keV. The detector has an energy
resolution of 4.0keV at 32keV, and the Infocus telescope has an angular
resolution of 2.2 arcminute and a field of view of about 10 arcminutes. Infocus
flew on a balloon mission in July 2001 and observed Cygnus X-1. We present
results from laboratory testing of the detector to measure the uniformity of
response across the detector, to determine the spectral resolution, and to
perform a simple noise decomposition. We also present a hard X-ray spectrum and
image of Cygnus X-1, and measurements of the hard X-ray CZT background obtained
with the SWIN detector on Infocus.Comment: To appear in the proceedings of the SPIE conference "Astronomical
Telescopes and Instrumentation", #4851-116, Kona, Hawaii, Aug. 22-28, 2002.
12 pages, 9 figure
X-ray Properties of the Weak Seyfert 1 Nucleus in NGC 4639
We obtained observations of NGC 4639 with ASCA in order to investigate its
mildly active Seyfert 1 nucleus at hard X-ray energies. Koratkar et al. (1995)
have previously shown that the nucleus is a pointlike source in the ROSAT soft
X-ray band. We detected in the 2-10 keV band a compact central source with a
luminosity of 8.3E+40 erg/s. Comparison of the ASCA data with archival data
taken with the Einstein and ROSAT satellites shows that the nucleus varies on
timescales of months to years. The variability could be intrinsic, or it could
be caused by variable absorption. More rapid variability, on a timescale of
\~10^4 s, may be present in the ASCA data. The spectrum from 0.5 to 10 keV is
well described by a model consisting of a lightly absorbed (N_H = 7.3E+20
cm^-2) power law with a photon index of 1.68. We find no evidence for
significant emission from a thermal plasma; if present, it can account for no
more than 25% of the flux in the 0.5-2.0 keV band. The limited photon
statistics of our data do not allow us to place significant limits on the
presence of iron K emission. (abridged)Comment: To appear in The Astrophysical Journal. LaTex, 18 pages including
embedded figures and table
The X-ray Spectrum of the Rapid Burster using the Chandra HETGS
We present observations of the Rapid Burster (RB, also known as MXB 1730-335)
using the Chandra High Energy Transmission Grating Spectrometer. The average
interval between type II (accretion) bursts was about 40 s. There was one type
I (thermonuclear flash) burst and about 20 "mini-bursts" which are probably
type II bursts whose peak flux is 10-40% of the average peak flux of the other
type II bursts. The time averaged spectra of the type II bursts are well fit by
a blackbody with a temperature of kT = 1.6 keV, a radius of 8.9 km for a
distance of 8.6 kpc, and an interstellar column density of 1.7e22 per sq. cm.
No narrow emission or absorption lines were clearly detected. The 3 sigma upper
limits to the equivalent widths of any features are < 10 eV in the 1.1-7.0 keV
band and as small as 1.5 eV near 1.7 keV. We suggest that Comptonization
destroys absorption features such as the resonance line of Fe XXVI.Comment: 10 pages, 4 figures, accepted for publication in AJ (with minor
changes and enhanced discussion of the instrument configuration
Design and tests of the hard X-ray polarimeter X-Calibur
X-ray polarimetry promises to give qualitatively new information about
high-energy astrophysical sources, such as binary black hole systems,
micro-quasars, active galactic nuclei, and gamma-ray bursts. We designed, built
and tested a hard X-ray polarimeter X-Calibur to be used in the focal plane of
the InFOCuS grazing incidence hard X-ray telescope. X-Calibur combines a low-Z
Compton scatterer with a CZT detector assembly to measure the polarization of
10-80 keV X-rays making use of the fact that polarized photons Compton scatter
preferentially perpendicular to the electric field orientation. X-Calibur
achieves a high detection efficiency of order unity.Comment: 9 pages, 5 figures, conference proceedings: SPIE 2011 (San Diego
- …