121 research outputs found

    Discrimination of Metallic and Colored Surface States by Optical Pattern Projection Method

    Get PDF
    Abstract In the optical pattern projection method called by the authors for surface roughness measurement, the roughness is detected from the qualities of the output image, such as contrast, formed by an imaging system including a target surface. We will report the relation between the roughness and contrasts for metallic surfaces and the colored plastics in the range of R a of about 0.1 µm and below, using a video camera. For the colored plastic surfaces, the authors explain that the sensitivity for gloss depends on the contrast of the formed image under additional illumination by other light sources

    Implant survival of constrained acetabular device in primary total hip arthroplasty based on data from the Finnish Arthroplasty Register

    Get PDF
    Background: Constrained acetabular devices were developed to prevent dislocations after total hip arthroplasty (THA). However, the data on their success have been contradictory. In this study, we aimed to assess implant survival of the constrained acetabular device in primary THA based on the Finnish Arthroplasty Register data. Methods: A total of 373 primary THAs with constrained acetabular devices inserted from 2006 to 2017 were included. A reference group was formed on a 1:3 basis and matched for age, sex, and diagnosis, consisting of 1118 conventional THAs. Implant survival estimates using death as a competing risk were assessed with revision for any reason and for any aseptic reason as the endpoints. The Cox multiple regression models were adjusted for age, sex, and diagnosis. The mean follow-up time was 3.3 (0-12.4) years for the constrained device group and 3.8 (0-12.0) years for the reference group. Results: Overall, there were 21 revisions in the constrained device group and 49 in the reference group. The 8-year survivorship for any reason was 94% (confidence interval [CI]: 91-96) for the constrained device group and 93% (CI: 89-97) for the reference group. With revision for any aseptic reason as the endpoint, the 8-year survivorships were 97% (CI: 95-99) and 94% (CI: 90-98), respectively. During the first 1.5 years, the constrained acetabular device group had a similar revision risk (hazard ratio: 1.09 [CI: 0.57-2.07], P = .8) to that of the reference group. Conclusion: The constrained acetabular device had good survival in primary THA, and our results support its continued use even in high-risk patients. (C) 2019 The Authors. Published by Elsevier Inc.Peer reviewe

    Long-term blood metal ion levels and clinical outcome after Birmingham hip arthroplasty

    Get PDF
    Background and objective: Our aim was to assess long-term metal ion level changes and clinical outcome in patients with a Birmingham hip arthroplasty. Methods: For the purpose of this study, we identified all BHR hip resurfacing arthroplasty (HRA) and total hip arthroplasty (THA) operations performed in Turku University Hospital. A random coefficient model was used to compare the change between the first and last metal ion measurement. A Kaplan-Meier estimator was used to assess the survivorship of the BHR HRA and BHR THA with metal related adverse events (pseudotumor, elevated metal ions above the safe upper limit, revision due to metallosis), or revision due to any reason as endpoints with 95% confidence intervals (CIs). Results: BHR HRA was used in 274 hips (233 patients). In addition, we identified 38 BHR-Synergy THAs (38 patients). Operations were performed between 2003 and 2010. Median follow-up time was 14 years for BHR HRA (range: 0.6-17) and 11 years for BHR THA (range: 4.7-13). In the BHR HRA group, geometric means of Cr and Co levels decreased from 2.1 to 1.6 ppb and 2.4 to 1.5 ppb, respectively, during a 3.0-year measurement interval. Metal ion levels in the BHR THA group did not show notable increase. The survivorship of BHR HRA was 66% in 16 years and 34% for BHR THA at 12 years for any metal-related adverse event. Conclusions: Patients with a Birmingham hip device do not seem to benefit from frequent repeated metal ion measurements. The amount of patients with metal-related adverse events was relatively high, but many of them did not require surgery

    Repeated metal ion measurements and long-term outcome of Durom/MMC total hip arthroplasty

    Get PDF
    Background and purpose — Data regarding long-term behavior of metal ion levels in metal-on-metal total hip arthroplasty (MoM THA) patients is scarce. Therefore, we assessed whether there is any change in whole blood (WB) chromium (Cr), and cobalt (Co) ion measurements in Durom and MMC MoM THA patients over time. The secondary aim was to report the clinical outcomes using these devices in a single district.Patients and methods — Durom and MMC cups were used in 249 MoM THAs from 2005 to 2011 in our district. Median follow-up time was 12 years for Durom THA (interquartile range [IQR] = 3) and 9 years for MMC THA (IQR = 1). A random coefficient model was used to compare individual differences in repeated WB Cr and Co ion measurements. The Kaplan–Meier estimator was used to analyze implant survival with any reason for revision as the endpoint.Results — Geometric means of Cr in Durom THA and MMC THA patients decreased from 2.2 ppb (geometric standard deviation [SD] = 1.9) to 1.5 ppb (geometric SD = 2.5, pInterpretation — WB Cr levels decreased over time, and Co levels remained unchanged at long-term follow-up. Despite this we recommend continuing the follow-up of these devices due to relatively low implant survival. </p

    Median 10-year whole blood metal ion levels and clinical outcome of ReCap-M2a-Magnum metal-on-metal total hip arthroplasty

    Get PDF
    BACKGROUND AND PURPOSE: We have previously reported that the whole blood (WB) chromium (Cr) and cobalt (Co) ion levels decrease in the short term after ReCap-M2a-Magnum large-diameter head (LDH) metal-on-metal (MoM) total hip arthroplasty (THA). This study reports long-term metal ion levels and clinical outcomes after ReCap-Magnum THA. PATIENTS AND METHODS: ReCap-M2a-Magnum LDH THA was used in 1,450 patients in our hospital district from 2005 to 2012. Median follow-up time was 10 years. 991 patients had 2 or more metal ion measurements. The median measurement interval was 4 years. Individual metal ion change was assessed using logarithmic metal ion values in a random coefficient model. Kaplan-Meier survival estimates were calculated for revision surgery for any reason for revision, and separately for metal-related adverse events (metal ions above safe upper limit [SUL], revision due to ARMD, or pseudotumor). RESULTS: Geometric mean of Cr decreased from 1.8 ppb (geometric standard deviation [GSD] 1.8) to 1.0 ppb (GSD 2.8, p < 0.001). The Co levels decreased from 1.7 ppb (GSD 2.4) to 1.4 ppb (GSD 2.8, p < 0.001). The hip-specific survival was 85% for revision due to any reason at 14 years and the hip-specific survival for any metal-related adverse event was 69% at 14 years. INTERPRETATION: WB Cr and Co levels continued to decrease in the long-term follow-up of ReCap-M2a-Magnum THA patients. The amount of metal-related adverse events was rather high, but revision surgery was seldom required. We suggest that after 10 years from the implantation a 5-year measurement interval may be sufficient for asymptomatic ReCap-M2a-Magnum patients.publishedVersionPeer reviewe

    Median 10-year whole blood metal ion levels and clinical outcome of ReCap-M2a-Magnum metal-on-metal total hip arthroplasty

    Get PDF
    Background and purposeWe have previously reported that the whole blood (WB) chromium (Cr) and cobalt (Co) ion levels decrease in the short term after ReCap-M2a-Magnum large-diameter head (LDH) metal-on-metal (MoM) total hip arthroplasty (THA). This study reports long-term metal ion levels and clinical outcomes after ReCap-Magnum THA.Patients and methodsReCap-M2a-Magnum LDH THA was used in 1,450 patients in our hospital district from 2005 to 2012. Median follow-up time was 10 years. 991 patients had 2 or more metal ion measurements. The median measurement interval was 4 years. Individual metal ion change was assessed using logarithmic metal ion values in a random coefficient model. Kaplan–Meier survival estimates were calculated for revision surgery for any reason for revision, and separately for metal-related adverse events (metalions above safe upper limit [SUL], revision due to ARMD, or pseudotumor).ResultsGeometric mean of Cr decreased from 1.8 ppb (geometric standard deviation [GSD] 1.8) to 1.0 ppb (GSD 2.8, p InterpretationWB Cr and Co levels continued to decrease in the long-term follow-up of ReCap-M2a-Magnum THA patients. The amount of metal-related adverse events was rather high, but revision surgery was seldom required. We suggest that after 10 years from the implantation a 5-year measurement interval may be sufficient for asymptomatic ReCap-M2a-Magnum patients.</p

    Implant survival of 2,723 vitamin E-infused highly crosslinked polyethylene liners in total hip arthroplasty: data from the Finnish Arthroplasty Register

    Get PDF
    Background and purpose - The use of crosslinked polyethylene in total hip arthroplasty (THA) has decreased wear remarkably. It has been suggested that the antioxidative effects of vitamin E may enhance the wear properties of polyethylene even further. This study evaluates revision rates between vitamin E-infused polyethylene liners (E1 and E-poly, ZimmerBiomet, Warsaw, IN, USA) versus moderately crosslinked polyethylene (ModXLPE) liners from the same manufacturer used in primary THA.Patients and methods - We conducted a study based on data from the Finnish Arthroplasty Register. The study group consisted of 2,723 THAs with a vitamin E-infused liner and a reference group of 2,707 THAs with a moderately crosslinked polyethylene liner. Survivorship, revision risk, and re-revision causes were compared between groups.Results - The 7-year survival of the vitamin E-infused polyethylene liner group and of the reference group with revision for any reason as the endpoint was comparable (94% [95% CI 92.9-94.9] and 93% [CI 91.9-93.9], respectively). The adjusted hazard ratio (HR) for any revision was similar between the groups (0.7 [CI 0.4-1.1]). When revision for aseptic loosening was studied as the endpoint, the survival for the study group was 99% (CI 98.6-99.4) and for the reference group 99% (CI 98.7-99.5), and the risk of revision was comparable between the study groups (HR 1.3 [CI 0.7-2.5]).Interpretation - After an observation period of 7 years vitamin E-infused liners shows results equal to results obtained with crosslinked polyethylene liners
    • …
    corecore