230 research outputs found
Recommended from our members
Suture-method versus Through-the-needle Catheters for Continuous Popliteal-sciatic Nerve Blocks: A Randomized Clinical Trial.
BACKGROUND:The basic perineural catheter design has changed minimally since inception, with the catheter introduced through or over a straight needle. The U.S. Food and Drug Administration recently cleared a novel perineural catheter design comprising a catheter attached to the back of a suture-shaped needle that is inserted, advanced along the arc of its curvature pulling the catheter past the target nerve, and then exited through the skin in a second location. The authors hypothesized that analgesia would be noninferior using the new versus traditional catheter design in the first two days after painful foot/ankle surgery with a primary outcome of average pain measured with the Numeric Rating Scale. METHODS:Subjects undergoing painful foot or ankle surgery with a continuous supraparaneural popliteal-sciatic nerve block 5 cm proximal to the bifurcation were randomized to either a suture-type or through-the-needle catheter and subsequent 3-day 0.2% ropivacaine infusion (basal 6 ml/h, bolus 4 ml, lockout 30 min). Subjects received daily follow-up for the first four days after surgery, including assessment for evidence of malfunction or dislodgement of the catheters. RESULTS:During the first two postoperative days the mean ± SD average pain scores were lower in subjects with the suture-catheter (n = 35) compared with the through-the-needle (n = 35) group (2.7 ± 2.4 vs. 3.4 ± 2.4) and found to be statistically noninferior (95% CI, -1.9 to 0.6; P < 0.001). No suture-style catheter was completely dislodged (0%), whereas the tips of three (9%) traditional catheters were found outside of the skin before purposeful removal on postoperative day 3 (P = 0.239). CONCLUSIONS:Suture-type perineural catheters provided noninferior analgesia compared with traditional catheters for continuous popliteal-sciatic blocks after painful foot and ankle surgery. The new catheter design appears to be a viable alternative to traditional designs used for the past seven decades
Decade-Spanning High-Precision Terahertz Frequency Comb
The generation and detection of a decade-spanning terahertz (THz) frequency comb is reported using two Ti:sapphire femtosecond laser oscillators and asynchronous optical sampling THz time-domain spectroscopy. The comb extends from 0.15 to 2.4 THz, with a tooth spacing of 80 MHz, a linewidth of 3.7 kHz, and a fractional precision of 1.8×10^(−9). With time-domain detection of the comb, we measure three transitions of water vapor at 10 mTorr between 1–2 THz with an average Doppler-limited fractional accuracy of 6.1×10^(−8). Significant improvements in bandwidth, resolution, and sensitivity are possible with existing technologies
A decade-spanning high-resolution asynchronous optical sampling terahertz time-domain and frequency comb spectrometer
We present the design and capabilities of a high-resolution, decade-spanning ASynchronous OPtical Sampling (ASOPS)-based TeraHertz Time-Domain Spectroscopy (THz-TDS) instrument. Our system employs dual mode-locked femtosecond Ti:Sapphire oscillators with repetition rates offset locked at 100 Hz via a Phase-Locked Loop (PLL) operating at the 60th harmonic of the ∼80 MHz oscillator repetition rates. The respective time delays of the individual laser pulses are scanned across a 12.5 ns window in a laboratory scan time of 10 ms, supporting a time delay resolution as fine as 15.6 fs. The repetition rate of the pump oscillator is synchronized to a Rb frequency standard via a PLL operating at the 12th harmonic of the oscillator repetition rate, achieving milliHertz (mHz) stability. We characterize the timing jitter of the system using an air-spaced etalon, an optical cross correlator, and the phase noise spectrum of the PLL. Spectroscopic applications of ASOPS-THz-TDS are demonstrated by measuring water vapor absorption lines from 0.55 to 3.35 THz and acetonitrile absorption lines from 0.13 to 1.39 THz in a short pathlength gas cell. With 70 min of data acquisition, a 50 dB signal-to-noise ratio is achieved. The achieved root-mean-square deviation is 14.6 MHz, with a mean deviation of 11.6 MHz, for the measured water line center frequencies as compared to the JPL molecular spectroscopy database. Further, with the same instrument and data acquisition hardware, we use the ability to control the repetition rate of the pump oscillator to enable THz frequency comb spectroscopy (THz-FCS). Here, a frequency comb with a tooth width of 5 MHz is generated and used to fully resolve the pure rotational spectrum of acetonitrile with Doppler-limited precision. The oscillator repetition rate stability achieved by our PLL lock circuits enables sub-MHz tooth width generation, if desired. This instrument provides unprecedented decade-spanning, tunable resolution, from 80 MHz down to sub-MHz, and heralds a new generation of gas-phase spectroscopic tools in the THz region
In-Air Evoked Potential Audiometry of Grey Seals (Halichoerus grypus) from the North and Baltic Seas
In-air anthropogenic sound has the potential to affect grey seal (Halichoerus grypus) behaviour and interfere with acoustic communication. In this study, a new method was used to deliver acoustic signals to grey seals as part of an in-air hearing assessment. Using in-ear headphones with adapted ear inserts allowed for the measurement of auditory brainstem responses (ABR) on sedated grey seals exposed to 5-cycle (2-1-2) tone pips. Thresholds were measured at 10 frequencies between 1–20 kHz. Measurements were made using subcutaneous electrodes on wild seals from the Baltic and North Seas. Thresholds were determined by both visual and statistical approaches (single point F-test) and good agreement was obtained between the results using both methods. The mean auditory thresholds were ≤40 dB re 20 µPa peak equivalent sound pressure level (peSPL) between 4–20 kHz and showed similar patterns to in-air behavioural hearing tests of other phocid seals between 3 and 20 kHz. Below 3 kHz, a steep reduction in hearing sensitivity was observed, which differed from the rate of decline in sensitivity obtained in behavioural studies on other phocids. Differences in the rate of decline may reflect influence of the ear inserts on the ability to reliably transmit lower frequencies or interference from the structure of the distal end of the ear canal
Motivation, optimal experience and flow in first year computing science.
We examine the concept of motivation from the perspective of Self Determination Theory and give a brief overview of relevant results. We also consider the optimal state known as Flow and give an account of its conceptualisation in the theory due to Csikszentmihalyi. After discussion of ways in which these concepts can be measured, we describe a set of preliminary studies that investigate motivation and flow in the context of a first year computing class. We analyse student responses to enquiries about perceptions of motivation and flow experiences and look at links between them. We also discuss intrinsic motivation within the subject
The OSIRIS-REx Visible and InfraRed Spectrometer (OVIRS): Spectral Maps of the Asteroid Bennu
The OSIRIS-REx Visible and Infrared Spectrometer (OVIRS) is a point
spectrometer covering the spectral range of 0.4 to 4.3 microns (25,000-2300
cm-1). Its primary purpose is to map the surface composition of the asteroid
Bennu, the target asteroid of the OSIRIS-REx asteroid sample return mission.
The information it returns will help guide the selection of the sample site. It
will also provide global context for the sample and high spatial resolution
spectra that can be related to spatially unresolved terrestrial observations of
asteroids. It is a compact, low-mass (17.8 kg), power efficient (8.8 W
average), and robust instrument with the sensitivity needed to detect a 5%
spectral absorption feature on a very dark surface (3% reflectance) in the
inner solar system (0.89-1.35 AU). It, in combination with the other
instruments on the OSIRIS-REx Mission, will provide an unprecedented view of an
asteroid's surface.Comment: 14 figures, 3 tables, Space Science Reviews, submitte
Auditory temporal resolution and evoked responses to pulsed sounds for the Yangtze finless porpoises (Neophocaena phocaenoides asiaeorientalis)
Author Posting. © The Author(s), 2011. This is the author's version of the work. It is posted here by permission of Springer for personal use, not for redistribution. The definitive version was published in Journal of Comparative Physiology A: Neuroethology, Sensory, Neural, and Behavioral Physiology 197 (2011): 1149-1158, doi:10.1007/s00359-011-0677-y.Temporal cues are important for some forms of auditory processing, such as
echolocation. Among odontocetes (toothed whales, dolphins, and porpoises), it has been
suggested that porpoises may have temporal processing abilities which differ from other
odontocetes because of their relatively narrow auditory filters and longer duration echolocation
signals. This study examined auditory temporal resolution in two Yangtze finless porpoises
(Neophocaena phocaenoides asiaeorientalis) using auditory evoked potentials (AEPs) to
measure: (i) rate following responses and modulation rate transfer function for 100 kHz centered
pulse sounds and (ii) hearing thresholds and response amplitudes generated by individual pulses
of different durations. The animals followed pulses well at modulation rates up to 1250 Hz, after
which response amplitudes declined until extinguished beyond 2500 Hz. The subjects had
significantly better hearing thresholds for longer, narrower-band pulses similar to porpoise
echolocation signals compared to brief, broadband sounds resembling dolphin clicks. Results
indicate that the Yangtze finless porpoise follows individual acoustic signals at rates similar to
other odontocetes tested. Relatively good sensitivity for longer duration, narrow-band signals
suggests that finless porpoise hearing is well-suited to detect their unique echolocation signals.The work was supported by the Office of Naval Research, a WHOI
Mellon Joint Initiatives Award , the Chinese National Natural Science Foundation (grant No:
30730018) and the Institute of Hydrobiology of the Chinese Academy of Sciences2012-09-1
Hearing Loss in Stranded Odontocete Dolphins and Whales
The causes of dolphin and whale stranding can often be difficult to determine. Because toothed whales rely on echolocation for orientation and feeding, hearing deficits could lead to stranding. We report on the results of auditory evoked potential measurements from eight species of odontocete cetaceans that were found stranded or severely entangled in fishing gear during the period 2004 through 2009. Approximately 57% of the bottlenose dolphins and 36% of the rough-toothed dolphins had significant hearing deficits with a reduction in sensitivity equivalent to severe (70–90 dB) or profound (>90 dB) hearing loss in humans. The only stranded short-finned pilot whale examined had profound hearing loss. No impairments were detected in seven Risso's dolphins from three different stranding events, two pygmy killer whales, one Atlantic spotted dolphin, one spinner dolphin, or a juvenile Gervais' beaked whale. Hearing impairment could play a significant role in some cetacean stranding events, and the hearing of all cetaceans in rehabilitation should be tested
- …