71 research outputs found

    Outcomes of primary vs. delayed strategy of implanting a cardiac monitor for unexplained syncope.

    Get PDF
    OBJECTIVE: Implantable cardiac monitors (ILR) have an important role in diagnosing unexplained syncope. However, outcomes of primary vs. delayed ILR implantation after initial syncope evaluation have not been explored. METHODS: A total of 1705 patients with unexplained syncope were prospectively enrolled in the SYSTEMA (Syncope Study of Unselected Population in Malmö) cohort. Patients who underwent cardiovascular autonomic testing (CAT) and ILR were grouped into those referred to CAT after ILR implantation (primary ILR) and those in whom ILR was indicated after CAT (post-CAT ILR). RESULTS: One-hundred-and-fifteen patients (6.7%) received ILRs. ILR recipients were older (58 vs. 52 years; p = 0.002), had more syncope recurrences (6 vs. 4; p < 0.001), more traumatic falls (72% vs. 53%; p < 0.001), and less prodrome (40% vs. 55%; p = 0.005) than patients without ILRs. During follow-up ≥16 months after ILR, 67 (58%) had normal sinus rhythm, 10 (8.7%) had sinus arrest, 10 (8.7%) AV-block, 13 (11.3%) atrial fibrillation, 9 (7.8%) supraventricular tachycardia, 4 (3.5%) sinus tachycardia and 2 (1.7%) ventricular tachycardia with clinical symptom reproduction. There were 52 patients (45%) in the primary-ILR group and 63 (55%) in the post-CAT ILR group. Proportions of negative ILR monitoring (17/52 vs. 25/63; p = 0.56) and pacemaker implantations (7/52 vs. 15/63; p = 0.23) did not differ between groups. Baseline ECG conduction disorders predicted pacemaker implantation (n = 11/17; odds ratio:10.6; 95%CI: 3.15-35.3; p < 0.001). CAT was more often positive (73% vs. 40%; p < 0.001) in primary-ILR group. CONCLUSIONS: Primary ILR implantation was associated with more positive CAT compared with delayed ILR implantation, but negative monitoring and pacemaker implantations were not different between groups. ECG conduction disorders predicted subsequent pacemaker implantation

    Pacing therapy in the management of unexplained syncope: a tertiary care centre prospective study

    Get PDF
    Objective: Pacemaker (PM) therapy is effective when syncope is associated with bradycardia, but syncope recurrences and fall injuries after PM implantation may occur. We aimed to survey indications and outcomes of PM implantation, following evaluation of unexplained syncope. Methods: Among 1666 consecutive unpaced patients investigated in a tertiary syncope unit by carotid-sinus massage (CSM), head-up tilt test (HUT) and ECG monitoring, 106 (6.4%; age, 65 ± 17 years) received a PM. We assessed bradycardia detection methods, PM implantation indications, and explored incidence of recurrent syncope, fall-related fractures and mortality. Results: Indications for PM therapy were met in 32/106 patients (30%) by CSM, in 41/106 (39%) by HUT, in 14/106 patients (13%) by implantable loop-recorder (ILR) and in 19/106 (18%) by standard ECG. Sinus arrest with asystole was the predominant PM indication during CSM/HUT and external ECG monitoring, whereas ILR detected proportionally the same numbers o f asystole due to sinus arrest and atrioventricular block. During follow-up (median, 4.3 years), 15 patients (14%) had syncope recurrence, 15 suffered fall-related fractures and 9 died. Neither syncope recurrence nor fall-related fractures were dependent on initial PM indication. The composite endpoint of recurrent syncope/fall-related fracture was associated with treated hypertension (OR 2.45; 95% CI 1.00 to 6.0), reduced glomerular filtration rate (OR 1.63 per 10 mL/min↓; 95% CI 1.22 to 2.19) and atrial fibrillation (OR 3.98; 95% CI 1.11 to 14.3). Recurrent syncope predicted increased mortality (OR 9.20; 95% CI 1.89 to 44.8). Conclusions: Cardiovascular autonomic testing and ECG monitoring effectively identify pacing indications in patients with unexplained syncope. After PM implantation, treated hypertension, renal failure and atrial fibrillation predict syncope recurrence and fall-related injury. Recurrent syncope predicts increased mortality

    Orthostatic hypotension: clinical review and case study

    Get PDF
    Transient loss of consciousness (TLOC) accounts for 3% of all attendance in emergency departments within the UK. More than 90% of TLOC presentations are due to epileptic seizures, psychogenic seizures or syncope. However, in England and Wales in 2002, it was estimated that 92000 patients were incorrectly diagnosed with epilepsy, at an additional annual cost to the NHS of up to ÂŁ189 million. This article will reflect on the case study of a 54-year-old female patient who presented with a possible TLOC, and had a background of long-term depression. Differential diagnoses will be discussed, but the article will focus on orthostatic hypotension. Being diagnosed with this condition is independently associated with an increased risk of all-cause mortality. Causes of orthostatic hypotension and the pathophysiology behind the condition will be discussed, highlighting the importance of obtaining an accurate clinical history. This is extremely pertinent if a patient collapses in an NHS setting and this is witnessed by nurses because they can contribute to the history of the type of collapse, to aid diagnosis and correct treatment. In addition, nurses have a valuable role to play in highlighting polypharmacy to doctors, and non-medical prescribers, as a contributing factor to orthostatic hypotension is polypharmacy. It is therefore important to accurately distinguish TLOC aetiology, not only to provide appropriate management, but to also identify patients at risk of morbidity/mortality related to underlying disease.N/

    Gallstone dissolution therapy with ursodiol

    No full text

    Cardiovascular risk in non-alcoholic fatty liver disease: mechanisms and therapeutic implications

    Get PDF
    New evidence suggests that non-alcoholic fatty liver disease (NAFLD) has a strong multifaceted relationship with diabetes and metabolic syndrome, and is associated with increased risk of cardiovascular events, regardless of traditional risk factors, such as hypertension, diabetes, dyslipidemia, and obesity. Given the pandemic-level rise of NAFLD-in parallel with the increasing prevalence of obesity and other components of the metabolic syndrome-and its association with poor cardiovascular outcomes, the question of how to manage NAFLD properly, in order to reduce the burden of associated incident cardiovascular events, is both timely and highly relevant. This review aims to summarize the current knowledge of the association between NAFLD and cardiovascular disease, and also to discuss possible clinical strategies for cardiovascular risk assessment, as well as the spectrum of available therapeutic strategies for the prevention and treatment of NAFLD and its downstream events

    Cardiovascular autonomic dysfunction is the most common cause of syncope in paced patients

    No full text
    Introduction: Syncope and orthostatic intolerance in paced patients constitute a common clinical dilemma. We, thus, aimed to determine the etiology of syncope and/or symptoms of orthostatic intolerance in paced patients. Methods: Among 1,705 patients with unexplained syncope and/or orthostatic intolerance that were investigated by cardiovascular autonomic tests, including Valsalva maneuver, active standing, carotid sinus massage, and tilt-testing, 39 patients (2.3%; age 65.6 years; 39% women) had a cardiac implantable electronic device (CIED). We explored past medical history, diagnoses found during cardiovascular autonomic tests, and the further clinical workup, in case of negative initial evaluation. Results: An etiology was identified during cardiovascular autonomic tests in 36 of the 39 patients. Orthostatic hypotension (n = 16; 41%) and vasovagal syncope (n = 12; 31%) were the most common diagnoses. There were no cases of pacemaker dysfunction. The original pacing indications followed guidelines (sick-sinus-syndrome in 16, atrioventricular block in 16, atrial fibrillation with bradycardia in five). Twenty-two of the 39 patients (56%) had experienced syncope prior to the original CIED implantation. Orthostatic hypotension was diagnosed in seven (32%) and vasovagal syncope in nine (41%) of these patients. Of the 17 patients that had not experienced syncope prior to the original CIED implantation, nine patients (53%) were diagnosed with orthostatic hypotension and vasovagal syncope was diagnosed in three (18%). Of the 39 patients, two had implantable cardioverter-defibrillators to treat malignant ventricular arrhythmias diagnosed after syncopal episodes. Conclusion: Cardiovascular autonomic tests reveal the etiology of syncope and/or orthostatic intolerance in the majority of paced patients. The most common diagnosis was orthostatic hypotension (40%) followed by vasovagal syncope (30%), whereas there were no cases of pacemaker dysfunction. Our results emphasize the importance of a complete diagnostic work-up, including cardiovascular autonomic tests, in paced patients that present with syncope and/or orthostatic intolerance
    • …
    corecore