44 research outputs found

    Planck scale effects in neutrino physics

    Full text link
    We study the phenomenology and cosmology of the Majoron (flavon) models of three active and one inert neutrino paying special attention to the possible (almost) conserved generalization of the Zeldovich-Konopinski-Mahmoud lepton charge. Using Planck scale physics effects which provide the breaking of the lepton charge, we show how in this picture one can incorporate the solutions to some of the central issues in neutrino physics such as the solar and atmospheric neutrino puzzles, dark matter and a 17 keV neutrino. These gravitational effects induce tiny Majorana mass terms for neutrinos and considerable masses for flavons. The cosmological demand for the sufficiently fast decay of flavons implies a lower limit on the electron neutrino mass in the range of 0.1-1 eV.Comment: 24 pages, 1 figure (not included but available upon request), LaTex, IC/92/196, SISSA-140/92/EP, LMU-09/9

    European measurement comparison of 137Cs, 40K and 90Sr in milk powder

    No full text

    Comparison of triple-to-double coincidence ratio (TDCR) efficiency calculations and uncertainty assessments for Tc-99.

    No full text
    A comparison exercise for data analysis was recently conducted by the Liquid Scintillation Counting Working Group (LSCWG) of the International Committee on Radionuclide Metrology (ICRM) to evaluate the uncertainties involved in applying different analysis methodologies (including computer programs) for the triple-to-double coincidence ratio (TDCR) method. The goals of the comparison were to (1) study differences in calculation results from different TDCR analysis programs, (2) investigate differences in analysis techniques and uncertainty assessment philosophies between laboratories, and (3) study the effect of not taking asymmetry of photomultiplier tube (PMT) efficiencies into account on the calculated activity. To achieve this, a single set of TDCR data for the pure beta emitter 99Tc, was distributed to the participants, who analyzed the data according to their normal procedures and report the activity concentration of the 99Tc solution from their results. The results indicate that the presently used programs are generally able to calculate the same activity values, assuming that the correct input parameters are used and that not taking PMT asymmetry into account in the calculations can lead to significant (0.6% for 99Tc) errors in reported results. The comparison also highlighted the need for a more rigorous approach to estimating and reporting uncertainties. © 2010, Elsevier Ltd
    corecore