22 research outputs found
Bones don’t lie: What does bone shape tell us about skeletal diseases?
Biomaterials & Tissue Biomechanic
Computer-assisted preoperative planning of bone fracture fixation surgery: A state-of-the-art review
Background: Bone fracture fixation surgery is one of the most commonly performed surgical procedures in the orthopedic field. However, fracture healing complications occur frequently, and the choice of the most optimal surgical approach often remains challenging. In the last years, computational tools have been developed with the aim to assist preoperative planning procedures of bone fracture fixation surgery.Objectives: The aims of this review are 1) to provide a comprehensive overview of the state-of-the-art in computer-assisted preoperative planning of bone fracture fixation surgery, 2) to assess the clinical feasibility of the existing virtual planning approaches, and 3) to assess their clinical efficacy in terms of clinical outcomes as compared to conventional planning methods.Methods: A literature search was performed in the MEDLINE-PubMed, Ovid-EMBASE, Ovid-EMCARE, Web of Science, and Cochrane libraries to identify articles reporting on the clinical use of computer-assisted preoperative planning of bone fracture fixation.Results: 79 articles were included to provide an overview of the state-of-the art in virtual planning. While patient-specific geometrical model construction, virtual bone fracture reduction, and virtual fixation planning are routinely applied in virtual planning, biomechanical analysis is rarely included in the planning framework. 21 of the included studies were used to assess the feasibility and efficacy of computer-assisted planning methods. The reported total mean planning duration ranged from 22 to 258 min in different studies. Computer-assisted planning resulted in reduced operation time (Standardized Mean Difference (SMD): -2.19; 95% Confidence Interval (CI): -2.87, -1.50), less blood loss (SMD: -1.99; 95% CI: -2.75, -1.24), decreased frequency of fluoroscopy (SMD: -2.18; 95% CI: -2.74, -1.61), shortened fracture healing times (SMD: -0.51; 95% CI: -0.97, -0.05) and less postoperative complications (Risk Ratio (RR): 0.64, 95% CI: 0.46, 0.90). No significant differences were found in hospitalization duration. Some studies reported improvements in reduction quality and functional outcomes but these results were not pooled for meta-analysis, since the reported outcome measures were too heterogeneous.Conclusion: Current computer-assisted planning approaches are feasible to be used in clinical practice and have been shown to improve clinical outcomes. Including biomechanical analysis into the framework has the potential to further improve clinical outcome.Biomaterials & Tissue Biomechanic
Hyperbolic origami-inspired folding of triply periodic minimal surface structures
Origami-inspired folding methods present novel pathways to fabricate three-dimensional (3D) structures from 2D sheets. A key advantage of this approach is that planar printing and patterning processes could be used prior to folding, affording enhanced surface functionality to the folded structures. This is particularly useful for 3D lattices, possessing very large internal surface areas. While folding polyhedral strut-based lattices has already been demonstrated, more complex, curved sheet-based lattices have not yet been folded due to inherent developability constraints of conventional origami. Here, a novel folding strategy is presented to fold flat sheets into topologically complex cellular materials based on triply periodic minimal surfaces (TPMS), which are attractive geometries for many applications. The approach differs from traditional origami by employing material stretching to accommodate non-developability. Our method leverages the inherent hyperbolic symmetries of TPMS to assemble complex 3D structures from a net of self-foldable patches. We also demonstrate that attaching 3D-printed foldable frames to pre-strained elastomer sheets enables self-folding and self-guided minimal surface shape adaption upon release of the pre-strain. This approach effectively bridges the Euclidean nature of origami with the hyperbolic nature of TPMS, offering novel avenues in the 2D-to-3D fabrication paradigm and the design of architected materials with enhanced functionality.Biomaterials & Tissue Biomechanic
Comparison in clinical performance of surgical guides for mandibular surgery and temporomandibular joint implants fabricated by additive manufacturing techniques
Additive manufacturing (AM) offers great design freedom that enables objects with desired unique and complex geometry and topology to be readily and cost-effectively fabricated. The overall benefits of AM are well known, such as increased material and resource efficiency, enhanced design and production flexibility, the ability to create porous structures and on-demand manufacturing. When AM is applied to medical devices, these benefits are naturally assumed. However, hard clinical evidence collected from clinical trials and studies seems to be lacking and, as a result, systematic assessment is yet difficult. In the present work, we have reviewed 23 studies on the clinical use of AM patient-specific surgical guides (PSGs) for the mandible surgeries (n = 17) and temporomandibular joint (TMJ) patient-specific implants (PSIs) (n = 6) with respect to expected clinical outcomes. It is concluded that the data published on these AM medical devices are often lacking in comprehensive evaluation of clinical outcomes. A complete set of clinical data, including those on time management, costs, clinical outcomes, range of motion, accuracy of the placement with respect to the pre-operative planning, and extra complications, as well as manufacturing data are needed to demonstrate the real benefits gained from applying AM to these medical devices and to satisfy regulatory requirements.Biomaterials & Tissue Biomechanic
Typical shape differences in the subtalar joint bones between subjects with chronic ankle instability and controls
Bone shapes, particularly those defining the subtalar joint (STJ), have not received much attention yet as a risk factor for developing chronic ankle instability (CAI) after sustaining a lateral ankle sprain (LAS). This study aimed to compare three-dimensional (3D) shape variations in the STJ bones within individuals with CAI and healthy controls. 3D statistical shape models (SSMs) of the STJ bones were built to describe the bone shape variations observed within a population consisting of 26 individuals with unilateral CAI and 26 healthy controls. Using the SSMs and analysis of covariance test, age- and gender-adjusted shape variations in the bones were compared within individuals with CAI and healthy controls. The mean age of the CAI patients (14 males and 12 females) and healthy controls (12 males and 14 females) was 29 (standard deviation [SD] = 11) and 36 years (SD = 11), respectively. Tali and calcanei did not significantly vary between ipsilateral CAI and their contralateral ankle. Two shape modes, one for the talus (p = 0.015, variations in the curvature of the talar lateral process and the inclination angle of the talar neck relative to the body) and one for the calcaneus (p = 0.003, variations in the medial and lateral tuberosities, and the contour of the anterior articular surface), described significant shape differences between the CAI patients and healthy controls. The CAI patients generally had flatter talar joint surfaces and a flattened calcaneal ground-contact surface. These findings suggest that specific bone shapes may increase the risk of developing CAI after sustaining a LAS.Biomaterials & Tissue Biomechanic
Three-dimensional registration of freehand-tracked ultrasound to CT Images of the Talocrural Joint
A rigid surface–volume registration scheme is presented in this study to register computed tomography (CT) and free-hand tracked ultrasound (US) images of the talocrural joint. Prior to registration, bone surfaces expected to be visible in US are extracted from the CT volume and bone contours in 2D US data are enhanced based on monogenic signal representation of 2D US images. A 3D monogenic signal data is reconstructed from the 2D data using the position of the US probe recorded with an optical tracking system. When registering the surface extracted from the CT scan to the monogenic signal feature volume, six transformation parameters are estimated so as to optimize the sum of monogenic signal features over the transformed surface. The robustness of the registration algorithm was tested on a dataset collected from 12 cadaveric ankles. The proposed method was used in a clinical case study to investigate the potential of US imaging for pre-operative planning of arthroscopic access to talar (osteo)chondral defects (OCDs). The results suggest that registrations with a registration error of 2 mm and less is achievable, and US has the potential to be used in assessment of an OCD’ arthroscopic accessibility, given the fact that 51% of the talar surface could be visualizedBiomaterials & Tissue BiomechanicsImPhys/Quantitative Imagin
Fatigue and quasi-static mechanical behavior of bio-degradable porous biomaterials based on magnesium alloys
Magnesium and its alloys have the intrinsic capability of degrading over time in vivo without leaving toxic degradation products. They are therefore suitable for use as biodegradable scaffolds that are replaced by the regenerated tissues. One of the main concerns for such applications, particularly in load-bearing areas, is the sufficient mechanical integrity of the scaffold before sufficient volumes of de novo tissue is generated. In the majority of the previous studies on the effects of biodegradation on the mechanical properties of porous biomaterials, the change in the elastic modulus has been studied. In this study, variations in the static and fatigue mechanical behavior of porous structures made of two different Mg alloys (AZ63 and M2) over different dissolution times ( 6, 12, and 24 h) have been investigated. The results showed an increase in the mechanical properties obtained from stress-strain curve (elastic modulus, yield stress, plateau stress, and energy absorption) after 6-12 h and a sharp decrease after 24 h. The initial increase in the mechanical properties may be attributed to the accumulation of corrosion products in the pores of the porous structure before degradation has considerably proceeded. The effects of mineral deposition was more pronounced for the elastic modulus as compared to other mechanical properties. That may be due to insufficient integration of the deposited particles in the structure of the magnesium alloys. While the bonding of the parts being combined in a composite-like material is of great importance in determining its yield stress, the effects of bonding strength of both parts is much lower in determining the elastic modulus. The results of the current study also showed that the dissolution rates of the studied Mg alloys were too high for direct use in human body.Biomaterials & Tissue Biomechanics(OLD) MSE-5BT/Biocatalysi
In-silico quest for bactericidal but non-cytotoxic nanopatterns
Nanopillar arrays that are bactericidal but not cytotoxic against the host cells could be used in implantable medical devices to prevent implant-associated infections. It is, however, unclear what heights, widths, interspacing, and shape should be used for the nanopillars to achieve the desired antibacterial effects while not hampering the integration of the device in the body. Here, we present an in-silico approach based on finite element modeling of the interactions between Staphylococcus aureus and nanopatterns on the one hand and osteoblasts and nanopatterns on the other hand to find the best design parameters. We found that while the height of the nanopillars seems to have little impact on the bactericidal behavior, shorter widths and larger interspacings substantially increase the bactericidal effects. The same combination of parameters could, however, also cause cytotoxicity. Our results suggest that a specific combination of height (120 nm), width (50 nm), and interspacing (300 nm) offers the bactericidal effects without cytotoxicity.Accepted Author ManuscriptBiomaterials & Tissue Biomechanic
Extrusion-based additive manufacturing of Mg-Zn alloy scaffolds
Porous biodegradable Mg and its alloys are considered to have a great potential to serve as ideal bone substitutes. The recent progress in additive manufacturing (AM) has prompted its application to fabricate Mg scaffolds with geometrically ordered porous structures. Extrusion-based AM, followed by debinding and sintering, has been recently demonstrated as a powerful approach to fabricating such Mg scaffolds, which can avoid some crucial problems encountered when applying powder bed fusion AM techniques. However, such pure Mg scaffolds exhibit a too high rate of in vitro biodegradation. In the present research, alloying through a pre-alloyed Mg-Zn powder was ultilized to enhance the corrosion resistance and mechanical properties of AM geometrically ordered Mg-Zn scaffolds simultaneously. The in vitro biodegradation behavior, mechanical properties, and electrochemical response of the fabricated Mg-Zn scaffolds were evaluated. Moreover, the response of preosteoblasts to these scaffolds was systematically evaluated and compared with their response to pure Mg scaffolds. The Mg-Zn scaffolds with a porosity of 50.3% and strut density of 93.1% were composed of the Mg matrix and MgZn2 second phase particles. The in vitro biodegradation rate of the Mg-Zn scaffolds decreased by 81% at day 1, as compared to pure Mg scaffolds. Over 28 days of static immersion in modified simulated body fluid, the corrosion rate of the Mg-Zn scaffolds decreased from 2.3 ± 0.9 mm/y to 0.7 ± 0.1 mm/y. The yield strength and Young's modulus of the Mg-Zn scaffolds were about 3 times as high as those of pure Mg scaffolds and remained within the range of those of trabecular bone throughout the biodegradation tests. Indirect culture of MC3T3-E1 preosteoblasts in Mg-Zn extracts indicated favorable cytocompatibility. In direct cell culture, some cells could spread and form filopodia on the surface of the Mg-Zn scaffolds. Overall, this study demonstrates the great potential of the extrusion-based AM Mg-Zn scaffolds to be further developed as biodegradable bone-substituting biomaterials.Biomaterials & Tissue BiomechanicsTeam Peyman TaheriTeam Arjan Mo
Controlled metal crumpling as an alternative to folding for the fabrication of nanopatterned meta-biomaterials
We designed and fabricated a simple setup for the controlled crumpling of nanopatterned, surface-porous flat metallic sheets for the fabrication of volume-porous biomaterials and showed that crumpling can be considered as an efficient alternative to origami-inspired folding. Before crumpling, laser cutting was used to introduce pores to the sheets. We then fabricated titanium (Ti) nanopatterns through reactive ion etching on the polished Ti sheets. Thereafter, nanopatterned porous Ti sheets were crumpled at two deformation velocities (i.e., 2 and 100 mm/min). The compression tests of the scaffolds indicated that the elastic modulus of the specimens vary in the range of 11.8–13.9 MPa. Micro-computed tomography scans and computational simulations of crumpled scaffolds were performed to study the morphological properties of the resulting meta-biomaterials. The porosity and pore size of the scaffolds remained within the range of those reported for trabecular bone. Finally, the in vitro cell preosteoblasts culture demonstrated the cytocompatibility of the nanopatterned scaffolds. Moreover, the aspect ratio of the cells residing on the nanopatterned surfaces was found to be significantly higher than those cultured on the control scaffolds, indicating that the nanopatterned surface may have a higher potential for inducing the osteogenic differentiation of the preosteoblasts.Biomaterials & Tissue BiomechanicsSupport Biomechanical Engineerin