28 research outputs found
Validation of a 3D CT method for measurement of linear wear of acetabular cups: A hip simulator study
Background We evaluated the accuracy and repeatability of a 3D method for polyethylene acetabular cup wear measurements using computed tomography (CT). We propose that the method be used for clinical in vivo assessment of wear in acetabular cups. Material and methods Ultra-high molecular weight polyethylene cups with a titanium mesh molded on the outside were subjected to wear using a hip simulator. Before and after wear, they were (1) imaged with a CT scanner using a phantom model device, (2) measured using a coordinate measurement machine (CMM), and (3) weighed. CMM was used as the reference method for measurement of femoral head penetration into the cup and for comparison with CT, and gravimetric measurements were used as a reference for both CT and CMM. Femoral head penetration and wear vector angle were studied. The head diameters were also measured with both CMM and CT. The repeatability of the method proposed was evaluated with two repeated measurements using different positions of the phantom in the CT scanner. Results The accuracy of the 3D CT method for evaluation of linear wear was 0.51 mm and the repeatability was 0.39 mm. Repeatability for wear vector angle was 17?. Interpretation This study of metal-meshed hip-simulated acetabular cups shows that CT has the capacity for reliable measurement of linear wear of acetabular cups at a clinically relevant level of accuracy
Alumina-on-Polyethylene Bearing Surfaces in Total Hip Arthroplasty
The long-term durability of polyethylene lining total hip arthroplasty (THA) mainly depends on periprosthetic osteolysis due to wear particles, especially in young active patients. In hip simulator study, reports revealed significant wear reduction of the alumina ceramic-on-polyethylene articulation of THA compared with metal-on-polyethylene bearing surfaces. However, medium to long-term clinical studies of THA using the alumina ceramic-on-polyethylene are few and the reported wear rate of this articulation is variable. We reviewed the advantages and disadvantages of ceramicon- polyethylene articulation in THA, hip simulator study and retrieval study for polyethylene wear, in vivo clinical results of THA using alumina ceramic-on-polyethylene bearing surfaces in the literature, and new trial alumina ceramic-onhighly cross linked polyethylene bearing surfaces
Periprosthetic DXA after total hip arthroplasty with short vs. ultra-short custom-made femoral stems
Background and purpose Dual-energy X-ray absorptiometry (DXA) analysis of the 7 periprosthetic Gruen zones is the most commonly used protocol to evaluate bone remodeling after the implantation of conventional femoral stems. We assessed the value of DXA after cementless primary total hip arthroplasty (THA) by comparing the effect of progressive shortening of the stem of two femoral implants on periprosthetic bone remodeling using a specifically developed protocol of analysis with 5 periprosthetic regions of interest (ROIs)
Alteration of the Amount and Morphology of Wear Particles by the Addition of Loading Profile Transitions During Artificial Hip Wear Testing
Current validation tests of total hip arthroplasty endo-prostheses capture only a single activity performed by patients: continuous walking. A more representative test that includes transitions from a static loaded position to dynamic motion would simulate common motions by patients in which they change from standing to walking. The introduction of such transitions into a traditional test protocol could provide insight into actual wear behaviours and more realistic wear particle properties such as size and shape. First, the introduction of transitions will increase the measured wear rate. Second, the amount of wear will be positively correlated to the number of transitions per day. Finally, the size and shape of polyethylene particle produced via testing with transitions will differ from those of a conventional continuous walking test. Three identical sets of four cobalt chromium femoral heads and sterilized acetabular cups sterilized in ethylene oxide were tested in 30 per cent bovine serum under three conditions: continuous walking (0 transitions/day), 10 transitions/day, and 100 transitions/day. A day was defined as 2500 steps. The static and peak dynamic loads were 260 N and 1.9 kN respectively. A testing duration of 106 cycles was completed for each of the three tests. The wear rate was found to be inversely related to the number of transitions. Particle analysis showed that the particle size decreased as the number of transitions increased. Particles from the 100 transitions/day test were more fibular and produced more particles of the size known to promote an immune reactive response. Contrary to our hypothesis, as the number of transitions performed by patients increased, the wear rate and accumulated wear decreased. In addition, as the number of transitions increased, a larger percentage of wear particles were in the submicron size range. Consequently, despite a decrease in wear due to the presence of loading profile transitions, there is a potentially greater risk of osteolysis owing to the increased production of immunoreactive particles
Clinical and radiographic results and wear performance in different generations of a cementless porous-coated acetabular cup
We compared clinical results and wear performance in two different generations of a cementless porous-coated cup, analysing the long-term results of 83 uncemented Harris-Galante I cups (32-mm femoral head) and 93 uncemented Harris-Galante II cups (28-mm femoral head). All polyethylene liners were gamma irradiated in air. Polyethylene linear wear was estimated using a software package. The minimum follow-up was 10 years. Nine Harris-Galante I cups and two Harris-Galante II cups were revised due to aseptic loosening or polyethylene problems. The mean femoral head penetration at 6 weeks after surgery was 0.15 ± 0.05 mm for the Harris-Galante I cups and 0.12 ± 0.03 for the Harris-Galante II cups (p < 0.001);but mean wear was 0.13 ± 0.23 mm per year for the Harris-Galante I cups and 0.11 ± 0.10 for the Harris-Galante II cups (p = 0.740). Most of the metallic shells in both groups showed stable fixation. The so-called second-generation cups had lower initial polyethylene wear that resulted in less polyethylene wear at the latest the follow-up, but the overall wear rate was similar in both groups despite the different femoral head sizes and the improved locking mechanism