46 research outputs found
Rare association of Turner syndrome and Mayer-Rokitansky-Kuster Hauser syndrome
Turner syndrome and Mayer-Rokitansky-Kuster-Hauser (MRKH) syndrome is a rare association. The incidences of Turner and MRKH syndromes are estimated at 1/2000 and 1/4500 female births respectively. This is a 23-year-old patient, born of a consanguineous marriage, who was referred to us for exploration of primary amenorrhoea. The karyotype, performed three times, from peripheral blood lymphocytes was 45X0. The diagnosis of Turner syndrome associated with MRKH syndrome was retained
Right-heart infective endocarditis: apropos of 10 cases
The prevalence and characteristics of right heart endocarditis in Africa are not well known. The aim of this study was to describe the epidemiological, clinical and laboratory profiles of patients with right-heart infective endocarditis. This was a 10-year retrospective study conducted in 2 cardiology departments in Dakar, Senegal. All patients who met the diagnosis of right heart infective endocarditis according to the Duke's criteria were included. We studied the epidemiological, clinical as well as their laboratory profiles. There were 10 cases of right-heart infective endocarditis representing 3.04% of cases of infective endocarditis. There was a valvulopathy in 3 patients, an atrial septal defect in 1 patient, parturiency in 2 patients and the presence of a pacemaker in one patient. Anaemia was present in 9 patients whilst leukocytosis in 6 patients. The port of entry was found to be oral in three cases, ENT in one case and urogenital in two cases. Apart from one patient with vegetations in the tricuspid and pulmonary valves, the rest had localized vegetation only at the tricuspid valve. However, blood culture was positive in only three patients. There was a favorable outcome after antibiotic treatment in 4 patients with others having complications; three cases of renal impairment, two cases of heart failure and one case of pulmonary embolism. There was one mortality. Right heart infective endocarditis is rare but associated with potentially fatal complications.Pan African Medical Journal 2015; 2
Influence du taux d’hémoglobine sur la réponse à la radiothérapie des cancers du col de l’utérus : Étude rétrospective de 31 cas au CHU de Dakar
Le cancer du col de l’utérus est actuellement le deuxième cancer gynécologique après celui de l’endomètre. Près de 50% des cas diagnostiqués à travers le monde pourraient profiter de la radiothérapie dont l’efficacité dépend en partie du taux d’hémoglobine. Ainsi, nous avons entrepris d’évaluer l’influence du taux d’hémoglobine sur la réponse à la radiothérapie des cancers du col de l’utérus. Il s’agit d’une étuderétrospective de janvier 2006 à janvier 2009 portant sur 31 dossiers de patientes admises pour un cancer du col de l’utérus et ayant bénéficié d’une radiothérapie exclusive. L’âge moyen des patientes était de 53 ans. Les tranches d’âge les plus représentées étaient celles de 44 à 55 ans et de 55 à 66 ans avec respectivement 16 et 12 patientes. Plus de la moitié des patientes 61,29% étaient anémiées en début de traitement. Des doses élevées de radiations étaient retrouvées chez les patientes anémiées. En effet, certains auteurs ont montré que les patientes anémiées avant de subir une radiothérapie développaient une radiorésistance tumorale liée à l’hypoxie tissulaire expliquant ces doses élevées. Ces résultats suggèrent une collaboration entre radiothérapeutes et biologistes pour un diagnostic précoce (clinique, biologique) de l’anémie et un suivi biologique des patientes pendant leur traitement afin d’éviter les radiorésistances tumorales et les effets radio-induits tardifs.Mots clés : Anémie, cancer, col utérin, radiothérapie
Systèmes à libération contrôlée pH-dépendants de principes actifs hydrophobes à partir d’oléogels
Les rhumatismes inflammatoires chroniques sont une cause importante d'invalidité dans le monde entier. De ce fait, les affections rhumatismales chroniques font peser une lourde charge sociale et économique sur toutes les sociétés, pas seulement sur celles où l’espérance de vie est élevée. L’objectif principal de ce travail était d’étudier le profil de libération pH-dépendante de principes actifs hydrophobes à partir d’oléogels oraux et/ou cutanés. La formulation des oléogels a été réalisée selon une méthode sol-gel, reproductible à grande échelle. La caractérisation et le suivi dans le temps ont montré une bonne stabilité des oléogels. Les valeurs de pH des oléogels étaient globalement acides (entre 4,3 et 5,8) et dépendaient de la quantité de gélifiant utilisée. Les études de libération du kétoprofène, principe actif hydrophobe, en fonction du pH des milieux de dissolution ont montré des profils de libération d’une cinétique du premier ordre d’équation =+. avec des coefficients de détermination proches de 1 (milieux à pH égal à 1,2 et 5,5). Une meilleure libération du kétoprofène a été obtenue dans un milieu intestinal simulé (pH égal à 6,8) pour les formulations qui présentaient déjà une saturation en milieu gastrique simulé (pH égal à 1,2). Cette étude qui a permis de formuler, d’évaluer et de modéliser le profil de libération du kétoprofène à partir d’oléogels peut constituer une étape importante dans un objectif de souveraineté thérapeutique des pays d’Afrique subsaharienne notamment le Sénégal.Mots clés : Oléogels, rhumatismes inflammatoires chroniques, kétoprofène, libération contrôlée, pH-dépendant.
English Title: pH-dependent controlled release systems of hydrophobic active pharmaceutical ingredients from oleogels
Chronic inflammatory rheumatism is a major cause of disability around the world. As a result, chronic rheumatic diseases place a heavy social and economic burden on all societies, not just those with high life expectancy. The main objective of this work was to control the pH-dependent release of hydrophobic active pharmaceutical ingredients from oral and / or skin oleogels. The formulation of the oleogels was carried out using a sol-gel large-scale reproducible method. Characterization and monitoring over time have shown good stability of the oleogels. The pH values of the oleogels were overall acid (between 4.3 and 5.8) and depended on the amount of gelling agent used. The release studies of ketoprofen, a hydrophobic active pharmaceutical ingredient, as a function of the pH of the dissolution media have shown release profiles of first-order kinetics of equation =+. with coefficients of determination close to 1 (media at pH equal to 1.2 and 5.5). Better release of ketoprofen was obtained in simulated intestinal medium (pH equal to 6.8) for formulations which already exhibited saturation in simulated gastric medium (pH equal to 1.2). This study, which made it possible to formulate, evaluate and model the release profile of ketoprofen from oleogels, may constitute an important step in an objective of therapeutic sovereignty of the countries of sub-Saharan Africa, particularly Senegal.Keywords: oleogels - chronic inflammatory rheumatism - ketoprofen - controlled release – pH-dependent
Analyse physico-chimique de l’eau de l’unité d’hémodialyse du chr de Saint- Louis (Sénégal)
L’insuffisance rénale chronique est un des problèmes majeurs de la santé publique dans le monde. Au Sénégal, une étude récente réalisée dans la population générale adulte avait retrouvé une prévalence de l’ordre de 6,1%. «L’eau pour dilution de concentrées d’hémodialyse» est produite en continue et utilisée en grande quantité chez l’hémodialysé chronique, donc il apparaît primordial de veiller à sa bonne qualité. Au Sénégal, aucune étude n’a été faite à ce jour pour évaluer l’efficacité du système de traitement de l’eau pour dilution des concentrés de dialyse dans les différents centres de dialyse du pays. L’objectif de ce travail est de contrôler l’efficacité du système de traitement de l’eau pour dilution de concentrées d’hémodialyse afin de s’assurer de son innocuité. Les prélèvements ont été effectués au niveau de trois points clés du circuit de traitement de l’eau pour hémodialyse. A l’entrée et à la sortie de l’osmoseur, à la sortie de la boucle de distribution. Les analyses ont été effectuées à l’aide d’électrodes spécifiques. Les valeurs de potentiels ont permis de tracer les courbes d’étalonnage. La détermination par régression des pentes et des ordonnées à l’origine de la relation de Nernst donne E(mV ) = B - A Log Cm avec des coefficients de corrélation variant entre 0,988 et 0,999 prouvant que 98% au moins des variations de tensions mesurées (E) sont attribuables à la concentration. L’analyse physico-chimique des teneurs en chlorures, nitrates et fluorures révèle des teneurs plus élevées à l’entrée de l’osmoseur qu’à la sortie. Ces basses valeurs découlent du rôle de l’osmoseur qui filtre une grande partie des électrolytes. Par contre, à la sortie de la boucle de distribution les teneurs en électrolytes des différents échantillons étaient plus importantes que celles à la sortie de l’osmoseur. Cette forte concentration en électrolytes atteste d’une pollution par la boucle de distribution de l’eau déjà filtrée par l’osmoseur. L’intérêt de cette étude réside dans le fait qu’elle met en lumière l’importance du contrôle de la qualité de l’eau pour l’hémodialyse et la nécessité d’un bon planning de maintenance préventive efficace de l’ensemble de la boucle de traitement d’eau au sein de chaque centre.© 2016 International Formulae Group. All rights reserved.Mots clés: Hémodialyse, eau, chlorures, fluorures, nitrates, électrodes spécifiquesEnglish Title: Physicochemical analysis of Saint–Louis regional hospital’s hemodialysis unit’s water (Senegal)English AbstractChronic kidney disease is a major public health problem worldwide. In Senegal, a recent study in the general adult population found a prevalence of about 6,1%. "Water for diluting concentrated hemodialysis" is produced and used continuously at high levels in hemodialysis chronic. It is therefore essential to ensure its quality. In Senegal, no study has been done to assess the effectiveness of water treatment system for dialysis concentrates dilution in different dialysis centers of the country. The objective of this work is to monitor the effectiveness of the water treatment system for hemodialysis concentrated dilution to ensure its safety. The samples were taken on key issues of hemodialysis water’s treatment circuit. Three levels of sampling were selected. At the entrance and at the outlet of the reverse osmosis unit at the outlet of the distribution loop. Analyses were performed using specific electrodes. Potential values allowed us to map the calibration curves. Determination by regression of slopes and intercepts of the Nernst relation gives with correlation coefficients ranging from 0.988 to 0.999 showing that at least 98% of the measured voltages fluctuations (E) are attributable to the concentration. Physicochemical analysis of the levels of chlorides, nitrates and fluorides reveals higher levels at the entrance of the reverse osmosis unit than at the outlet. These low values resulting of the role of reverse osmosis which filter much of the electrolytes. For against, at the outlet of the distribution loop the electrolyte content of the different samples were greater than those at the outlet of the reverse osmosis unit. This high electrolyte concentration attests to pollution of the water distribution loop already filtered by reverse osmosis. The interest of this study lies in the fact that it highlights the importance of monitoring the quality of water for hemodialysis and the need for good planning for effective preventive maintenance throughout the water treatment loop within each center.© 2016 International Formulae Group. All rights reserved.Keywords: Hemodialysis, water, nitrates, fluoride, chloride, specific electrode
PERSISTANCE DU VITRE PRIMITIF, A PROPOS DE DEUX CAS FAMILIAUX
BUT  Rapporter deux cas familiaux de persistance du vitré primitif (PVP) bilatéral et d’évoquer la problématique de la prise en charge.OBSERVATIONS Il s’agissait de deux frères ( Cas 1 âgé de 09 ans  et Cas 2 âgé de 11 ans), issus d’un mariage consanguin de premier degré. Ils présentaient une malvoyance depuis la naissance. L’examen ophtalmologique montrait:pour le Cas1, une acuité visuelle limitée à « compte les doigts à 3m » à droite et une perception lumineuse à gauche; un nystagmus horizontal bilatéral , un cordon fibroglial vasculaire, une séclusion pupillaire et une leucocorie, aux deux yeux. L’échographie oculaire mode B 10 Hertz montrait un reliquat hyaloïdien postérieur à l’oeil droit. et un cordon papillo-capsulaire dense à  l’oeil gauche; et pour le Cas 2, une acuité visuelle chiffrée à une perception lumineuse à droite et « compte les doigts à 1m » à gauche. Aux deux yeux, nous retrouvions un nystagmus pendulaire, un strabisme, et au fond d’œil : un cordon fibro-vasculaire et des calcifications. L’échographie mode B avait permis d’objectiver un cordon allant de la papille à la face postérieure du cristallin aux deux yeux.La prise en charge chez nos deux Cas consistait en une rééducation basse vision ainsi qu’un conseil génétique.CONCLUSIONLa persistance du vitré primitif, pathologie rare, avec un pronostic fonctionnel souvent réservé. La prévention de l’amblyopie et le conseil génétique sont une part importante de la prise charge.Mots clés : vitré, nystagmus, rééducation, génétique