15 research outputs found

    Kaposiform hemangioendothelioma in tonsil of a child associated with cervical lymphangioma: a rare case report

    Get PDF
    Kaposiform hemangioendothelioma (KHE) is an uncommon vascular tumor of intermediate malignant potential, usually occurs in the extremities and retroperitoneum of infants and is characterized by its association with lymphangiomatosis and Kasabach-Merritt phenomenenon (KMP) in certain cases. It has rarely been observed in the head and neck region and at times, can present without KMP. Herein, we present an extremely uncommon case of KHE occurring in tonsil of a child, associated with a neck swelling, but unassociated with KMP. A 2-year-old male child referred to us with history of sore throat, dyspnoea and right-sided neck swelling off and on, since birth, was clinicoradiologically diagnosed with recurrent tonsillitis, including right sided peritonsillar abscess, for which he underwent right-sided tonsillectomy, elsewhere. Histopathological sections from the excised tonsillar mass were reviewed and showed a tumor composed of irregular, infiltrating lobules of spindle cells arranged in kaposiform architecture with slit-like, crescentic vessels. The cells displayed focal lumen formation containing red blood cells (RBCs), along with platelet thrombi and eosinophilic hyaline bodies. In addition, there were discrete foci of several dilated lymphatic vessels containing lymph and lymphocytes. On immunohistochemistry (IHC), spindle cells were diffusely positive for CD34, focally for CD31 and smooth muscle actin (SMA), the latter marker was mostly expressed around the blood vessels. Immunostaining for HHV8 was negative and Ki-67 (proliferation marker) displayed focal positivity. Diagnosis of KHE was made. Platelet count was towards lower side of range. Postoperative imaging showed discrete, multiple fluid containing lesions in the right neck that were high on T2-weighed sequences, on magnetic resonance imaging (MRI) and ipsilateral intraoral mucosal growth. Fine needle aspiration cytology (FNAC) smears from neck swelling showed blood, fluid and lymphocytes. Possibility of a coexisting lymphangioma was considered. The patient was offered sclerotherapy and is on follow-up. This case forms the second documented case of KHE at this site, along with its unique association with neck lymphangioma. KHE has distinct histopathological features and can be sorted out from its other differentials like juvenile hemangioma and Kaposi's sarcoma. IHC stains are useful in substantiating a definite diagnosis

    Needle(s) in the Haystack – Synchronous Multifocal Tumor Induced Osteomalacia

    Get PDF
    This is the author accepted manuscript. The final version is available from Endocrine Society via http://dx.doi.org/10.1210/jc.2015-3854MG is supported by the NIHR Cambridge Biomedical Research Centre

    Microwave ablation: How we do it?

    No full text
    Minimally invasive techniques such as Image guided thermal ablation are now widely used in the treatment of tumors. Microwave ablation (MWA) is one of the newer modality of thermal ablation and has proven its safety and efficacy in the management of the tumors amenable for ablation for primary and metastatic diseases. It is used in the treatment of primary and secondary liver malignancies, primary and secondary lung malignancies, renal and adrenal tumors and bone metastases. We wanted to share our initial experience with this newer modality. In this article we will describe the mechanism and technique of MWA, comparison done with RFA, advantages and disadvantages of MWA along with pre procedure workup, post procedure follow-up and review of literature

    Pictorial essay: Vascular interventions in extra cranial head and neck

    No full text
    Medicine is an ever changing field and interventional radiology (IR) procedures are becoming increasingly popular because of high efficacy and its minimally invasive nature of the procedure. Management of disease processes in the extra cranial head and neck (ECHN) has always been a challenge due to the complex anatomy of the region. Cross sectional imaging of the ECHN has grown and evolved tremendously and occupies a pivotal and integral position in the clinical management of variety of head and neck pathologies. Advances in angiographic technologies including flat panel detector systems, biplane, and 3-dimensional rotational angiography have consolidated and expanded the role of IR in the management of various ECHN pathologies. The ECHN is at cross roads between the origins of great vessels and the cerebral vasculature. Thorough knowledge of functional and technical aspects of neuroangiography is essential before embarking on head and neck vascular interventions. The vessels of the head and neck can be involved by infectious and inflammatory conditions, get irradiated during radiotherapy and injured due to trauma or iatrogenic cause. The ECHN is also a common site for various hypervascular neoplasms and vascular malformations, which can be treated with endovascular and percutaneous embolization. This pictorial essay provides a review of variety of ECHN pathologies which were managed by various IR procedures using different approaches

    Percutaneous repair of iatrogenic subclavian artery injury by suture-mediated closure device

    No full text
    Central venous catheterization through internal jugular vein is done routinely in intensive care units. It is generally safe, more so when the procedure is performed under ultrasound guidance. However, there could be inadvertent puncture of other vessels in the neck when the procedure is not performed under real-time sonographic guidance. Closure of this vessel opening can pose a challenge if it is an artery, in a location difficult to compress, and is further complicated by deranged coagulation profile. Here, we discuss the removal of an inadvertently placed catheter from subclavian artery with closure of arteriotomy percutaneously using arterial suture-mediated closure device

    CT-guided radiofrequency ablation in osteoid osteoma: Result from a tertiary cancer centre in India

    No full text
    Aims: The aim of this study is to evaluate the clinical efficacy of computed tomography (CT)-guided radiofrequency (RF) ablation as a minimally invasive therapy for osteoid osteoma. Materials and Methods: This is a retrospective analysis of prospectively maintained data of 43 symptomatic osteoid osteoma patients who were treated by radiofrequency ablation (RFA). Forty out of 43 patients were naive cases and underwent primary treatment for osteoid osteoma with RFA, whereas 3 patients included in the study underwent RFA for local recurrence after having undergone surgical treatment. Diagnosis was based on clinical and characteristic imaging findings, and biopsy was done for cases with atypical presentation. Pre and post procedure Visual Analog Score (VAS) was documented in all cases. Monopolar RFA system was used in all patients, and the electrode was placed within the lesion nidus under CT guidance coaxially through 11G introducer needle. Ablation was performed at 90° C for 5 min. Results: Technical success rate of intranidal placement of electrode was 100%. The primary clinical success in our study was 97.7% (42 of 43), and the secondary clinical success was 100%.Pre and postprocedure VAS score in our study group was 7.8 and 0.4, respectively. Mean follow-up period in our study was 48 months (Range: 4–129 months).One patient had recurrence of pain 4 years after treatment and was treated successfully by a second session. Minor complications were seen in 3 patients with two cases of RF pad burns and one case of skin burn at the treatment site, and these were managed conservatively. No patients developed temporary/permanent neurological deficits, and no procedure-related mortality was seen in our study. Conclusion: CT-guided percutaneous RFA is a simple, safe, minimally invasive, and highly effective treatment option for osteoid osteoma with good long-term pain control and potentially low disease recurrence

    Impact of the activity calculation method used in transarterial radioembolization:a dosimetric comparison between 90Y-SIRSphere and 90Y-TheraSphere therapy

    No full text
    PURPOSE: Transarterial radioembolization is used to treat primary and secondary liver malignancies. Two commercially available drugs are utilized for the purpose. The aim of our study is to compare the radiation dose delivered to the tumor by these drugs.MATERIALS AND METHODS: This study included 86 patients (M : F - 7.6 : 1, median age=50.5 years), 46 patients were treated by Y-TheraSphere and 42 patients were treated by Y-SIRSphere. Activity administered in Y-TheraSphere and Y-SIRSphere was calculated using a modified partition model and a modified body surface area model, respectively. The radiation dose delivered by two drugs was calculated and compared in our study.RESULT: Activity administered in Y-TheraSphere was significantly higher than that of Y-SIRSphere. Hence, the radiation dose delivered to the tumor by Y-SIRSphere was significantly lower (58.4%) than that of Y-TheraSphere (P=0.000).CONCLUSION: As the radiation dose delivered by Y-SIRSphere was lower than Y-TheraSphere, we believe that the formula for Y-SIRSphere activity calculation needs to be modified so that the optimal dose can be delivered to the tumor.</p

    Software development for hepatopulmonary shunt estimation by gamma camera method in transarterial radioembolization

    Get PDF
    Trans-arterial radioembolization (TARE) is an established treatment for inoperable hepatocellular carcinoma and liver metastases from Carcinoma of gastrointestinal tract. Radiation-induced toxicity to the lung parenchyma is the dose-limiting factor in TARE. Pretreatment hepatopulmonary shunt (HPS) is estimated by gamma camera method by transarterial administration of 370MBq 99mTc macro aggregated albumin. We have developed HPS software on XELERIS-1.123 workstation, GE medical systems, Milwaukee, USA, for accurate calculation of HPS. This software has also been tested on a higher version of XELERIS workstation, and it has been found to work well in all versions.</p
    corecore