241 research outputs found

    Comparative study of assay of free radical damage in in vivo, in vitro and ex vivo conditions

    Get PDF
    Background: Interception of free radical events and damage in clinical situation remain arbitrary with poor understanding on antioxidant pharmacology. Methods: Experiments on in vitro per-oxidation insult as well as assumed free radical damage situation in ischemia reperfusion are examined for profile of malondialdehyde rise and effect of Gikgobiloba treatment by different schedule.Results: Effect of Ginkgobiloba was seen on ischemia reperfusion induced, hydrogen peroxide induced and ferric chloride induced methods. Antioxidant effect of Ginkgobiloba was consistent in all techniques.Conclusions: Results reveal the significance of complementary experiment to elaborate issue of antioxidants

    RESEARCH AND REVIEWS: JOURNAL OF PHARMACOLOGY AND TOXICOLOGICAL STUDIES Effect of Ginkgo biloba on Renal Ischemia-Reperfusion Induced Oxidant Stress in Rats

    Get PDF
    ABSTRACT Ginkgo biloba extract was evaluated for prophylactic value against renal ischemia-reperfusion induced oxidant stress in rat subjected to transient unilateral renal artery ligation. Oral Ginkgo biloba treatment (2mg/kg) was administered by different schedule before experimental induction of ischemia-reperfusion injury. Malondialdehyde has been taken as indicator for free radical damage produced by ischemia-reperfusion injury. Three hour pretreatment by the drug has most prominent inhibitory effect on consequent tissue and plasma malondialdehyde level of lipid peroxidation. Further, the relative inhibition of malondialdehyde level in tissue and plasma allow to infer drug effect on generation, but not the clearance of malondialdehyde. No significant difference of outcome from 1, 2 and 3 days treatment indicate no cumulation and thus safety in that respect. Ginkgo biloba treatment appears both effective and safe for prophylaxis of reperfusion injury following ischemia catastrophies

    A comparative study on patient specific absolute dosimetry using slab phantom, acrylic body phantom and goat head phantom

    Get PDF
    Purpose: To compare the results of patient specific absolute dosimetry using slab phantom, acrylic body phantom and goat head phantom. Methods: Fifteen intensity modulated radiotherapy (IMRT) plans already planned on treatment planning system (TPS) for head-and-neck cancer patients were exported on all three kinds of phantoms viz. slab phantom, acrylic body phantom and goat head phantom, and dose was calculated using anisotropic analytic algorithm (AAA). All the gantry angles were set to zero in case of slab phantom while set to as it is in actual plan in case of other two phantoms. All the plans were delivered by linear accelerator (LA) and dose for each plan was measured by 0.13 cc ion chamber. The percentage (%) variations between planned and measured doses were calculated and analyzed. Results: The mean % variations between planned and measured doses of all IMRT quality assurance (QA) plans were as 0.65 (Standard deviation (SD): 0.38) with confidence limit (CL) 1.39, 1.16 (SD: 0.61) with CL 2.36 and 2.40 (SD: 0.86) with CL 4.09 for slab phantom, acrylic head phantom and goat head phantom respectively. Conclusion: Higher dose variations found in case of real tissue phantom compare to results in case of slab and acrylic body phantoms. The algorithm AAA does not calculate doses in heterogeneous medium as accurate as it calculates in homogeneous medium. Therefore the patient specific absolute dosimetry should be done using heterogeneous phantom mimicking density wise as well as design wise to the actual human body.

    A comparative study on patient specific absolute dosimetry using slab phantom, acrylic body phantom and goat head phantom

    Get PDF
    Purpose: To compare the results of patient specific absolute dosimetry using slab phantom, acrylic body phantom and goat head phantom. Methods: Fifteen intensity modulated radiotherapy (IMRT) plans already planned on treatment planning system (TPS) for head-and-neck cancer patients were exported on all three kinds of phantoms viz. slab phantom, acrylic body phantom and goat head phantom, and dose was calculated using anisotropic analytic algorithm (AAA). All the gantry angles were set to zero in case of slab phantom while set to as it is in actual plan in case of other two phantoms. All the plans were delivered by linear accelerator (LA) and dose for each plan was measured by 0.13 cc ion chamber. The percentage (%) variations between planned and measured doses were calculated and analyzed. Results: The mean % variations between planned and measured doses of all IMRT quality assurance (QA) plans were as 0.65 (Standard deviation (SD): 0.38) with confidence limit (CL) 1.39, 1.16 (SD: 0.61) with CL 2.36 and 2.40 (SD: 0.86) with CL 4.09 for slab phantom, acrylic head phantom and goat head phantom respectively. Conclusion: Higher dose variations found in case of real tissue phantom compare to results in case of slab and acrylic body phantoms. The algorithm AAA does not calculate doses in heterogeneous medium as accurate as it calculates in homogeneous medium. Therefore the patient specific absolute dosimetry should be done using heterogeneous phantom mimicking density wise as well as design wise to the actual human body.  </p

    Plastic Surgery—Myths and Realities in Developing Countries: Experience from Eastern Nepal

    Get PDF
    B.P. Koirala Institute of Health Sciences, Dharan, Nepal, is the only tertiary care referral centre in the eastern region of Nepal. This paper discusses the author's experience of starting a plastic surgery unit in eastern Nepal regarding need and present status of plastic surgery care in Nepal. Methods. We analyzed the data of patients treated in Plastic surgery unit from July 2007 to February 2009. We did evaluation regarding type of patients, procedures, and their outcome. We also evaluated the limitations and their possible solutions to overcome the barriers to establish effective plastic surgical centers in developing countries. Results. Plastic surgery services were started as a unit in general surgery by single plastic surgeon and one general surgery resident on rotation. Total 848 patients were treated for different plastic-surgery-related conditions, which included 307 acute burn patients 541 general plastic surgery patients. Trauma constituted the major bulk 22%, followed by tumors 20%, while aesthetic surgery operations were only 10.1%. Conclusions. In developing countries, aesthetic procedures constitute very small part of plastic surgery interventions and plastic surgery units are primarily required for reconstructive needs for optimum management of patients

    Evaluating the Performance of Hybrid Capture 2 Test as a Primary Screening Test from Studies Conducted in Low and Middle-Income Country Settings-Special Focus India

    Get PDF
    Among the screening tests for cervical cancer, advantages of screening with second generation molecular Hybrid Capture 2 (HC2) test is the high sensitivity and negative predictive value that makes it easy to implement as a cervical cancer screening policy necessitating less screening rounds. High income countries are now implementing HC2 test in their national cervical cancer screening program. Since the acceptance of any screening test depends on the sensitivity of the test, the current study was carried out to evaluate the sensitivity of HC2 test reported from Low- and Middle-income countries (LMIC) which share major burden of cervical cancer globally and to establish if HC2 test could be used as a primary screening test in India. Materials and methods: The population based cross sectional studies from LMICs which evaluated HC2 test as a primary screening modality to diagnose Cervical intraepithelial neoplasm grade 2 and above (CIN2+) lesions were included. Results: A total of 18 studies from LMIC involving 1,13,086 women were reviewed for sensitivity of HC2 as a primary screening test. The overall average sensitivity and specificity to diagnose CIN2+ lesions were 79.84% (95% CI-71.01,86.73) and 85.63% (95% CI- 84.37,86.92) respectively. India demonstrated an average sensitivity and specificity of 65% (95% CI 57,77) and 93% (95% CI- 92,94) respectively. Conclusion: Results from LMIC demonstrate a comparably low sensitivity of HC2 test to diagnose CIN2+ lesions as compared to that reported from High income countries. Sensitivity of HC2 was substantially low for India. The current study discusses issues of HC2 assay and the role of untreated Reproductive tract infections as probable causes for low sensitivity of the test. This needs further research in an attempt to improve the sensitivity of the test in an era of self-sampling and low-cost HPV test on horizon to improve the coverage for cervical cancer

    Evaluating the Performance of Hybrid Capture 2 Test as a Primary Screening Test from Studies Conducted in Low and Middle-Income Country Settings-Special Focus India

    Get PDF
    Among the screening tests for cervical cancer, advantages of screening with second generation molecular Hybrid Capture 2 (HC2) test is the high sensitivity and negative predictive value that makes it easy to implement as a cervical cancer screening policy necessitating less screening rounds. High income countries are now implementing HC2 test in their national cervical cancer screening program. Since the acceptance of any screening test depends on the sensitivity of the test, the current study was carried out to evaluate the sensitivity of HC2 test reported from Low- and Middle-income countries (LMIC) which share major burden of cervical cancer globally and to establish if HC2 test could be used as a primary screening test in India. Materials and methods: The population based cross sectional studies from LMICs which evaluated HC2 test as a primary screening modality to diagnose Cervical intraepithelial neoplasm grade 2 and above (CIN2+) lesions were included. Results: A total of 18 studies from LMIC involving 1,13,086 women were reviewed for sensitivity of HC2 as a primary screening test. The overall average sensitivity and specificity to diagnose CIN2+ lesions were 79.84% (95% CI-71.01,86.73) and 85.63% (95% CI- 84.37,86.92) respectively. India demonstrated an average sensitivity and specificity of 65% (95% CI 57,77) and 93% (95% CI- 92,94) respectively. Conclusion: Results from LMIC demonstrate a comparably low sensitivity of HC2 test to diagnose CIN2+ lesions as compared to that reported from High income countries. Sensitivity of HC2 was substantially low for India. The current study discusses issues of HC2 assay and the role of untreated Reproductive tract infections as probable causes for low sensitivity of the test. This needs further research in an attempt to improve the sensitivity of the test in an era of self-sampling and low-cost HPV test on horizon to improve the coverage for cervical cancer
    • …
    corecore