122 research outputs found

    Ketogenic diet-induced weight loss is associated with an increase in vitamin d levels in obese adults

    Get PDF
    Vitamin D is an important micronutrient involved in several processes. Evidence has shown a strong association between hypovitaminosis D and cardio-metabolic diseases, including obesity. A ketogenic diet has proven to be very effective for weight loss, especially in reducing fat mass while preserving fat-free mass. The aim of this study was to investigate the effect of a ketogenic diet-induced weight loss on vitamin D status in a population of obese adults. We enrolled 56 obese outpatients, prescribed with either traditional standard hypocaloric Mediterranean diet (SHMD) or very low-calorie ketogenic diet (VLCKD). Serum 25(OH)D concentrations were measured by chemiluminescence. The mean value of serum 25-hydroxyvitamin D (25(OH)D) concentrations in the whole population at baseline was 17.8 +/- 5.6 ng/mL, without differences between groups. After 12 months of dietetic treatment, in VLCKD patients serum 25(OH)D concentrations increased from 18.4 +/- 5.9 to 29.3 +/- 6.8 ng/mL (p < 0.0001), vs 17.5 +/- 6.1 to 21.3 +/- 7.6 ng/mL (p = 0.067) in the SHMD group (for each kilogram of weight loss, 25(OH)D concentration increased 0.39 and 0.13 ng/mL in the VLCKD and in the SHMD groups, respectively). In the VLCKD group, the increase in serum 25(OH)D concentrations was strongly associated with body mass index, waist circumference, and fatty mass variation. In a multiple regression analysis, fatty mass was the strongest independent predictor of serum 25(OH)D concentration, explaining 15.6%, 3.3%, and 9.4% of its variation in the whole population, in SHMD, and VLCKD groups, respectively. We also observed a greater reduction of inflammation (evaluated by high-sensitivity C reactive protein (hsCRP) values) and a greater improvement in glucose homeostasis, confirmed by a reduction of HOMA values, in the VLCKD versus the SHMD group. Taken together, all these data suggest that a dietetic regimen, which implies a great reduction of fat mass, can improve vitamin D status in the obese

    Immunity, Inflammation and Heart Failure: Their Role on Cardiac Function and Iron Status

    Get PDF
    Aims: Heart failure is a clinical syndrome characterized by subclinical systemic inflammation and immune system activation associated with iron deficiency. No data exist on the various activations of immune-mediated mechanisms of inflammation in heart failure patients with reduced/preserved ejection fraction. We aimed to (1) investigate possible differences in inflammatory parameters and oxidative stress, and (2) detect a different iron status between groups. Materials and Methods: We enrolled 50 consecutive Caucasian outpatients with heart failure. All patients underwent echocardiographic measurements, laboratory determinations, evaluation of iron status and Toll-like receptors, and NF-κB expression in peripheral blood mononuclear cells, as well as pro-inflammatory cytokines. All statistical calculations were made using SPSS for Mac version 21.0. Results: Patients with reduced ejection fraction showed significantly lower hemoglobin levels (12.3 ± 1.4 vs. 13.6 ± 1.4 g/dl), serum iron (61.4 ± 18.3 vs. 93.7 ± 33.7 mcg/dl), transferrin iron binding capacity (20.7 ± 8.4 vs. 31.1 ± 15.6 %), and e-GFR values (78.1 ± 36.1 vs. 118.1 ± 33.9 ml/min/1.73 m2) in comparison to patients with preserved ejection fraction, while unsaturated iron binding capacity (272.6 ± 74.9 vs. 221.7 ± 61.4 mcg/dl), hepcidin (4.61 ± 0.89 vs. 3.28 ± 0.69 ng/ml), and creatinine (1.34 ± 0.55 vs. 1.03 ± 0.25 mg/dl) were significantly higher in the same group. When considering inflammatory parameters, patients with reduced ejection fraction showed significantly higher expression of both Toll-like receptors-2 (1.90 ± 0.97 vs. 1.25 ± 0.76 MFI) and Toll-like receptors-4 (4.54 ± 1.32 vs. 3.38 ± 1.62 MFI), respectively, as well as a significantly higher activity of NF-κB (2.67 ± 0.60 vs. 1.07 ± 0.30). Furthermore, pro-inflammatory cytokines, interleukin-1, and interleukin-6, was significantly higher in patients with reduced ejection fraction, while the protective cytokine interleukin-10 was significantly lower in the same group. Correlational analyses demonstrated a significant and inverse relationship between left ventricular function and inflammatory parameters in patients with reduced ejection fraction, as well as a direct correlation between ferritin and inflammatory parameters. Conclusions: Our data demonstrate a different immune-mediated inflammatory burden in heart failure patients with reduced or preserved ejection fraction, as well as significant differences in iron status. These data contribute to further elucidate pathophysiologic mechanisms leading to cardiac dysfunction

    Endothelial dysfunction and C-reactive protein predict the incidence of heart failure in hypertensive patients

    Get PDF
    Aims: Endothelial dysfunction and heart failure are associated, but no prospective studies demonstrated that impaired endothelium-dependent vasodilation predicts incident heart failure. We designed this study to test whether endothelial dysfunction is associated with incident heart failure in a group of hypertensives. Methods and results: We enrolled 735 White never-treated hypertensive outpatients free from heart failure, diabetes, chronic kidney disease, and previous cardiovascular events. Endothelium-dependent vasodilation was investigated by intra-arterial infusion of acetylcholine, and laboratory determinations were obtained by standard procedures. During the follow-up [median 114 months (range 26–206)], there were 208 new cases of heart failure (3.1 events/100 patient-years). Dividing the study population in progressors and non-progressors, we observed that progressors were older, showed a higher prevalence of being female, and had a higher baseline heart rate, glucose, insulin, Homeostatic Model Assessment (HOMA), creatinine, and high-sensitivity C-reactive protein (hs-CRP) mean values, while estimated glomerular filtration rate and maximal acetylcholine-stimulated forearm blood flow were lower. In the multiple Cox regression analysis, female gender [hazard ratio (HR) = 1.454, 95% CI = 1.067–1.981], fasting glucose (HR = 1.186, 95% CI = 1.038–1.357), hs-CRP (HR = 1.162, 95% CI = 1.072–1.259), HOMA (HR = 1.124, 95% CI = 1.037–1.219), acetylcholine-stimulated forearm blood flow (HR = 0.779, 95% CI = 0.695–0.874), and estimated glomerular filtration rate (HR = 0.767, 95% CI = 0.693–0.849) maintained an independent association with the outcome. Successively, testing the interaction between forearm blood flow and hs-CRP, we observed that patients who have hs-CRP values above the median and forearm blood flow under the median show a higher risk of developing heart failure (HR = 7.699, 95% CI = 4.407–13.451). Conclusions: The present data demonstrate that an impaired endothelium-dependent vasodilation and hs-CRP predict development of incident heart failure in hypertensives

    COPD significantly increases cerebral and cardiovascular events in hypertensives

    Get PDF
    Essential hypertension and chronic obstructive pulmonary disease often coexist in the same patient. The aim of this study was to evaluate whether the addition of chronic obstructive pulmonary disease modifies the risk of cardiovascular events in hypertensives. We enrolled 1728 hypertensives. Study outcomes included fatal and non-fatal cardiovascular stroke and myocardial infarction, and cardiovascular death. During a mean follow-up of 57 months there were 205 major adverse cardiovascular events (2.47 per 100 pts/yr): cardiac (n117; 1.41 per 100 pts/yr) and cerebrovascular (n = 77; 0.93 per 100 pts/yr). In hypertensives with chronic obstructive pulmonary disease we observed a greater number of cardiovascular events than in hypertensives without respiratory disease (133 [5.55 per 100 pts/yr) vs 72 [1.22 per 100 pts/yr], respectively. The addition of chronic obstructive pulmonary disease to hypertension increased the incidence of total and non-fatal stroke of more than nine- (2.42 vs 0.32 per 100 pts/yr) and 11-fold (2.09 vs 0.22 per 100 pts/yr), respectively. The same trend was observed for total (2.88 vs 0.81 per 100 pts/yr) and non-fatal (2.67 vs 0.79 per 100 pts/y) myocardial infarction. The presence of chronic obstructive pulmonary disease in hypertensives significantly increases the risk of stroke, myocardial infarction and major adverse cardiovascular events

    Outcome of the Commissioning of the Readout and Actuation Channels for the Cryogenics of the LHC

    Get PDF
    The LHC is the largest cryogenic installation ever built. For its operation more than 14 000 sensors and actuators are required. The 27 km circumference of the accelerator is divided into 8 sectors: like for the rest of the hardware and in particular the cryogenics, the commissioning of the cryogenics instrumentation has been performed sector by secto

    Instrumentation, Field Network and Process Automation for the Cryogenic System of the LHC Test String

    Get PDF
    CERN is now setting up String 2, a full-size prototype of a regular cell of the LHC arc. It is composed of two quadrupole, six dipole magnets, and a separate cryogenic distribution line (QRL) for the supply and recovery of the cryogen. An electrical feed box (DFB), with up to 38 High Temperature Superconducting (HTS) leads, powers the magnets. About 700 sensors and actuators are distributed along four Profibus DP and two Profibus PA field buses. The process automation is handled by two controllers, running 126 Closed Control Loops (CCL). This paper describes the cryogenic control system, associated instrumentation, and their commissioning

    The Cryogenic System for the LHC Test String 2: Design, Commissioning and Operation

    Get PDF
    A 107-m long superconducting magnet string representing a full-cell of the LHC machine was designed for assembly and commissioning at CERN in order to validate the final design choices. This new facility, thereafter called Test String 2, and its cryogenic infrastructure cons ist of feed and return boxes coupled via transfer lines to a 6 kW @ 4.5 K refrigerator and to a low pressure pumping group, a separate cryogenic distribution line, an electrical feed box with HTS current leads, 2 quadrupole and 6 dipole prototype and pre-series superconducting magnets

    Sexual and functional outcomes of prostate artery embolisation. A prospective long-term follow-up, large cohort study.

    Get PDF
    Among minimally invasive procedures for treating benign prostate hyperplasia (BPH) prostate artery embolisation (PAE) is described as safe and effective. Aim of this study is to report our results, focusing on sexual outcomes (erectile and ejaculatory functions sparing) of PAE in patients suffering from bladder outlet obstruction (BOO) secondary to BPH

    Sexual function after pelic organ prolapse surgery. Trocarless Transvaginal Mesh (TTMS) vs. laparoscopic transperitoneal pelvic organ prolapse suspension

    Get PDF
    Stress urinary incontinence (SUI) and low urinary tract symptoms related to pelvic organs prolapse represent a common condition that negatively impacts on female sexuality (FS). The repair of this anatomical/functional condition could affect female sexual function. Laparoscopic approach known as “pelvic organ prolapse surgery” (POPs) or the anterior repair with a trocar-less trans-vaginal mesh (TTMs) represent two different surgical techniques to reach functional and sexual improvements. This study aimed to compare the results of minimally invasive approach (POPs) with open trans-vaginal mesh tape repair for the correction of SUI and to evaluate the different outcomes on sexual activity and urinary symptoms

    First Experience with the LHC Cryogenic Instrumentation

    Get PDF
    The LHC under commissioning at CERN will be the world's largest superconducting accelerator and therefore makes extensive use of cryogenic instruments. These instruments are installed in the tunnel and therefore have to withstand the LHC environment that imposes radiation-tolerant design and construction. Most of the instruments require individual calibration; some of them exhibit several variants as concerns measuring span; all relevant data are therefore stored in an Oracle® database. Those data are used for the various quality assurance procedures defined for installation and commissioning, as well as for generating tables used by the control system to configure automatically the input/output channels. This paper describes the commissioning of the sensors and the corresponding electronics, the first measurement results during the cool-down of one machine sector; it discusses the different encountered problems and their corresponding solutions
    • …
    corecore