521 research outputs found

    Ru-Catalyzed, cis-Selective Living Ring-Opening Metathesis Polymerization of Various Monomers, Including a Dendronized Macromonomer, and Implications to Enhanced Shear Stability

    Get PDF
    An unsaturated polymer’s cis/trans-olefin content has a significant influence on its properties. For polymers obtained by ring-opening metathesis polymerization (ROMP), the cis/trans-olefin content can be tuned by using specific catalysts. However, cis-selective ROMP has suffered from narrow monomer scope and lack of control over the polymerization (giving polymers with broad molecular weight distributions and prohibiting the synthesis of block copolymers). Herein, we report the versatile cis-selective controlled living ROMP of various endo-tricyclo[4.2.2.0^(2,5)]deca-3,9-diene and various norbornene derivatives using a fast-initiating dithiolate-chelated Ru catalyst. Polymers with cis-olefin content as high as 99% could be obtained with high molecular weight (up to M_n of 105.1 kDa) and narrow dispersity (<1.4). The living nature of the polymerization was also exploited to prepare block copolymers with high cis-olefin content for the first time. Furthermore, owing to the successful control over the stereochemistry and narrow dispersity, we could compare cis- and trans-rich polynorbornene and found the former to have enhanced resistance to shear degradation

    Deep Seawater flow Characteristics Around the Manganese Nodule Collecting Device

    Get PDF
    AbstractFlow field characteristics with outflow discharge from a collecting device in deep seawater while gathering manganese nodules have been analyzed by CFD. Numerical model is used for the analysis with CFD program of FLUENT. It is assumed that the collecting device is 4.5×5.4×6.7m with outflow speed = 1.75 m/s and the current speed = 0.1m/s.Overall seawater flow field characteristics are largely influenced by the outflow discharge from the collecting device and manganese nodule particle behavior. The outflow discharge effect reaches to about few times of the collecting device in back. As simulation results, flow velocity and streamline distributions are compared including turbulence kinetic energyvariation. This study will be useful for optimal design for manganese nodule collecting device system in deep sea

    나이에 따른 얕은 수면에서의 정수리 파형의 특징

    Get PDF
    The significance of sleep disorders is underestimated in our society. The number of sleep disorders is over 80 in recent classifications of sleep disorders. And the incidence and prevalence of sleep disorders are very high compared to other medical illnesses. The consequences of sleep disorders such as medical illness, surgical illness, and accident may cause serious burden not only to our individual health but also to our society both medically and socioeconomically. By reviewing economical cost of sleep disorders, we can see the seriousness of this condition and can find out what to do for the improvement to better condition.OAIID:oai:osos.snu.ac.kr:snu2012-01/102/2014017262/12SEQ:12PERF_CD:SNU2012-01EVAL_ITEM_CD:102USER_ID:2014017262ADJUST_YN:NEMP_ID:A079623DEPT_CD:801CITE_RATE:0DEPT_NM:의학과SCOPUS_YN:NCONFIRM:

    The impact of sequential versus single anastomoses on flow characteristics and mid-term patency of saphenous vein grafts in coronary bypass grafting

    Get PDF
    ObjectiveTo assess the influence of bypass grafting technique on the flow characteristics and mid-term patency of saphenous vein coronary bypass grafts.MethodsIn the present study, 309 patients who underwent either sequential (group A, N = 84 grafts) or individual (group B, N = 244 grafts) saphenous vein coronary bypass grafting between February 2002 and September 2007 were investigated. Individual bypassing only was performed in 212 patients, and sequential bypassing only was performed in 78 patients. The remaining 19 patients received both. A total of 436 distal anastomoses were performed with 328 saphenous vein grafts. The intraoperative flow characteristics and the graft patency were assessed with the transit time flow meter and serial multi-detector computed tomography coronary angiograms, respectively.ResultsGroup A showed a higher mean flow compared with group B at 49.4 ± 27.4 mL/min versus 37.1 ± 20.1 mL/min, respectively (P = .001). The mean flow increased linearly as the number of anastomoses increased per graft (P < .001). Graft patency at 3 years was 93.3% ± 3.4% in group A and 86.5% ± 3.1% in group B (P = .048). After adjustment for baseline characteristics, group A showed a tendency for superior mid-term patency than group B (hazard ratio 0.362; 95% confidence interval, 0.129–1.017; P = .0538).ConclusionsSequential bypass grafts were associated with higher mean flows and superior mid-term patency compared with individual grafts. These findings suggest the more favorable results of sequential bypass grafting to be attributed to the enhanced flow hemodynamics

    Evaluation of Early Bone Response to Fluoride-Modified and Anodically Oxidized Titanium Implants Through Continuous Removal Torque Analysis

    Get PDF
    PURPOSE: To compare between a bioactive and a bioinert implant with different geometries by continuous measurement of the removal torque and calculation of the angular momentum of each surfaced implant.MATERIALS AND METHODS: Six New Zealand white rabbits were used in the study. Each rabbit received 2 implants. A bioactive fluoride-modified implant with a conical connection and microthread design was inserted into one tibia, and a bioinert anodically oxidized implant with an external connection design was inserted into the other. After 2 weeks of implant insertion, the removal torque values were continuously measured according to time. Using the time-torque curve resulting from the measurements, the maximum values were determined, and the angular momenta were calculated.RESULTS: The anodically oxidized implant had significantly higher peak removal torque and angular momentum values than the fluoride-modified implant (P < 0.05).CONCLUSIONS: The impact of the fluoride-modified bioactive implant on early bone response remains unclear. Considering the angular momentum of dental implants may assist in the elucidation of the effect of implant geometry on bone response.OAIID:oai:osos.snu.ac.kr:snu2012-01/102/2008003883/3SEQ:3PERF_CD:SNU2012-01EVAL_ITEM_CD:102USER_ID:2008003883ADJUST_YN:NEMP_ID:A078517DEPT_CD:861CITE_RATE:1.05FILENAME:Implant Dent 201210 21(5) 427-32.pdfDEPT_NM:치의학과EMAIL:[email protected]_YN:YCONFIRM:

    Kinematics Characteristic of Lower Extremity during Simulated Skiing Exercise

    Get PDF
    We analyze the kinematic factors of sectional and total movements in healthy participants to providing group dependent information during simulated exercise. Participants in this study's experiment were 26 male adults, the elapsed times in each phase, the difference in the lower extremity angles, and muscle activity were computed through analysis of kinematic factors. We revealed that motions of the experts took shorter to perform than non-experts, and showed larger variation of lower limb joint angle in most events during simulated skiing. There were also significant group dependent differences in the peak and mean EMG values during simulated skiing. Referring to these results, such a non-expert's posture leads to enhance muscle activity to keep the lower body in balance. Non-experts should maintain appropriate ROM with lower-intensity exercise to improve muscle endurance initially, and it can be useful in providing preliminary data for future training and rehabilitation studies, as well as improvements in muscle strength

    Identification of a bioactive core sequence from human laminin and its applicability to tissue engineering

    Get PDF
    Finding bioactive short peptides derived from proteins is a critical step to the advancement of tissue engineering and regenerative medicine, because the former maintains the functions of the latter without immunogenicity in biological systems. Here, we discovered a bioactive core nonapeptide sequence, PPFEGCIWN (residues 2678e2686; Ln2-LG3-P2-DN3), from the human laminin a2 chain, and investigated the role of this peptide in binding to transmembrane proteins to promote intracellular events leading to cell functions. This minimum bioactive sequence had neither secondary nor tertiary structures in a computational structure prediction. Nonetheless, Ln2-LG3-P2-DN3 bound to various cell types as actively as laminin in cell adhesion assays. The in vivo healing tests using rats revealed that Ln2-LG3-P2-DN3 promoted bone formation without any recognizable antigenic activity. Ln2-LG3-P2-DN3-treated titanium (Ti) discs and Ti implant surfaces caused the enhancement of bone cell functions in vitro and induced faster osseointegration in vivo, respectively. These findings established a minimum bioactive sequence within human laminin, and its potential application value for regenerative medicine, especially for bone tissue engineering.OAIID:oai:osos.snu.ac.kr:snu2015-01/102/2008003883/7ADJUST_YN:YEMP_ID:A078517DEPT_CD:861CITE_RATE:8.557FILENAME:044-biomaterials 201512 73() 96-109.pdfDEPT_NM:치의학과SCOPUS_YN:YCONFIRM:

    Epidermal Growth Factor Receptor Mutation and Pathologic-Radiologic Correlation Between Multiple Lung Nodules with Ground-Glass Opacity Differentiates Multicentric Origin from Intrapulmonary Spread

    Get PDF
    IntroductionNo standard guidelines detailing recommendations for the selection and treatment for multiple lung nodules with ground-glass opacity (GGO) have been established. For treatment decision, we analyzed epidermal growth factor receptor (EGFR)/K-ras somatic aberrations and pathologic-radiologic correlation in multiple lung nodules presented as GGO to differentiate multifocal lesions from intrapulmonary spread.MethodsTwenty-four patients with multiple lung nodules presented as GGO were identified to investigate somatic mutations of EGFR (exon 18–21) and K-ras (codons 2, 13, and 61). This series included 18 atypical adenomatous hyperplasias (AAH), 15 bronchioloalveolar carcinomas (BAC), and 23 adenocarcinomas (ADC) obtained from 24 patients.ResultsHigh frequency of discordant EGFR mutations (17 of 24, 70.8%) could discriminate tumor clonality (18 of 24, 75%) of multiple lung neoplastic nodules presented as GGO. EGFR mutations were common in AAH (38.9%), BAC (46.7%), and ADC (39.1%). In case 4, AAH and BAC had different mutational changes, and in case 10, the BAC lesion contains EGFR mutation that is not in the invasive ADC. In case 17, the BAC had more mutational changes than the carcinoma. The pure GGO appearance in the radiologic examination corresponded preinvasive pathologic change.ConclusionsThis study showed that synchronous BAC and/or ADC can have different EGFR or K-ras mutational profiles suggesting these lesions arise as independent events rather than intrapulmonary spread or systemic metastasis. This has significant implication in staging and treatment. These findings might be a clue to establish guidelines of the multiple neoplastic lung nodules with GGO
    corecore