8 research outputs found
Acute Complication Due to Impella 2.5 Device (Superficial Femoral Artery Thrombosis): Managed Successfully with Novel Aspiration Thrombectomy Catheter (Pronto V3)
The Impella recover LP 2.5 is a percutaneous left ventricular assist device (LVAD) recently approved for use in patients undergoing high risk percutaneous coronary intervention (PCI) and also in cases of cardiogenic shock. There is limited evidence available in literature about its safety, especially with regards to the incidence of local vascular complications, their management and long-term implications. We report here the first case of a serious local vascular complication—superficial femoral artery thrombus formation during Impella recover LP 2.5 use in a high risk PCI which was managed successfully with novel aspiration thrombectomy catheter (Pronto V3), which in itself is the first reported use of Pronto V3 in such a vascular complication
Isolated Left Ventricular Noncompaction Cardiomyopathy diagnosed by Transesophageal Echocardiography
Isolated noncompaction of the ventricular myocardium has often been misdiagnosed as other cardiomyopathies because it is a relatively recently described cardiomyopathy with literature limited to case reports and case series and little awareness among physicians. We are reporting a case of isolated left ventricular noncompaction cardiomyopathy that was misdiagnosed for over two decades
Long-term myocardial recovery after mitral valve replacement in noncompaction cardiomyopathy
Isolated noncompaction of the left ventricle is a congenital cardiomyopathy, which has been described recently, with literature limited to case reports and case series. Even though various complications have been reported with noncompaction cardiomyopathy, among them severe mitral regurgitation has been reported recently in a few cases. There is no great evidence in the literature about its management, apart from some cases of mitral valve repair and replacement in young patients. We are reporting a case of an elderly lady with isolated left ventricular noncompaction cardiomyopathy associated with severe mitral regurgitation treated with mitral valve replacement with one and half year of follow up demonstrating significant myocardial recovery
Electromagnetic Interference with Implantable Cardioverter Defibrillators Causing Inadvertent Shock: Case Report and Review of Current Literature
As the number of patients having implantable cardioverter defibrillator (ICD) devices is increasing, it is important for the physicians and patients to be aware of situations and conditions that can result in interference with normal functioning of these devices. There are multiple cases of malfunction of ICDs reported in literature and it may be of great significance to have an overview of these incidents for appropriate recognition and future prevention. Here we are reviewing the available literature as well as reporting an interesting case of electromagnetic interference (EMI) resulting from leak of current in pool water causing firing of ICD