323 research outputs found

    Latent Painter

    Full text link
    Latent diffusers revolutionized the generative AI and inspired creative art. When denoising the latent, the predicted original image at each step collectively animates the formation. However, the animation is limited by the denoising nature of the diffuser, and only renders a sharpening process. This work presents Latent Painter, which uses the latent as the canvas, and the diffuser predictions as the plan, to generate painting animation. Latent Painter also transits one generated image to another, which can happen between images from two different sets of checkpoints

    Topic Grids for Homogeneous Data Visualization

    Full text link
    We propose the topic grids to detect anomaly and analyze the behavior based on the access log content. Content-based behavioral risk is quantified in the high dimensional space where the topics are generated from the log. The topics are being projected homogeneously into a space that is perception- and interaction-friendly to the human experts

    Delayed versus immediate inoculation of sputum media for diagnosis of pneumonia

    Get PDF

    Preparation, characterization, and application of titanium nano-tube array in dye-sensitized solar cells

    Get PDF
    The vertically orientated TiO2 nanotube array (TNA) decorated with TiO2 nano-particles was successfully fabricated by electrochemically anodizing titanium (Ti) foils followed by Ti-precursor post-treatment and annealing process. The TNA morphology characterized by SEM and TEM was found to be filled with TiO2 nano-particles interior and exterior of the TiO2 nano-tubes after titanium (IV) n-butoxide (TnB) treatment, whereas TiO2 nano-particles were only found inside of TiO2 nano-tubes upon titanium tetrachloride (TiCl4) treatment. The efficiency in TNA-based DSSCs was improved by both TnB and TiCl4 treatment presumably due to the increase of dye adsorption

    Clinical application of tumor volume in advanced nasopharyngeal carcinoma to predict outcome

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Current staging systems have limited ability to adjust optimal therapy in advanced nasopharyngeal carcinoma (NPC). This study aimed to delineate the correlation between tumor volume, treatment outcome and chemotherapy cycles in advanced NPC.</p> <p>Methods</p> <p>A retrospective review of 110 patients with stage III-IV NPC was performed. All patients were treated first with neoadjuvant chemotherapy, then concurrent chemoradiation, and followed by adjuvant chemotherapy as being the definitive therapy. Gross tumor volume of primary tumor plus retropharyngeal nodes (GTVprn) was calculated to be an index of treatment outcome.</p> <p>Results</p> <p>GTVprn had a close relationship with survival and recurrence in advanced NPC. Large GTVprn (≧13 ml) was associated with a significantly poorer local control, lower distant metastasis-free rate, and poorer survival. In patients with GTVprn ≧ 13 ml, overall survival was better after ≧4 cycles of chemotherapy than after less than 4 cycles.</p> <p>Conclusions</p> <p>The incorporation of GTVprn can provide more information to adjust treatment strategy.</p

    Survival rate in nasopharyngeal carcinoma improved by high caseload volume: a nationwide population-based study in Taiwan

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Positive correlation between caseload and outcome has previously been validated for several procedures and cancer treatments. However, there is no information linking caseload and outcome of nasopharyngeal carcinoma (NPC) treatment. We used nationwide population-based data to examine the association between physician case volume and survival rates of patients with NPC.</p> <p>Methods</p> <p>Between 1998 and 2000, a total of 1225 patients were identified from the Taiwan National Health Insurance Research Database. Survival analysis, the Cox proportional hazards model, and propensity score were used to assess the relationship between 10-year survival rates and physician caseloads.</p> <p>Results</p> <p>As the caseload of individual physicians increased, unadjusted 10-year survival rates increased (<it>p </it>< 0.001). Using a Cox proportional hazard model, patients with NPC treated by high-volume physicians (caseload ≥ 35) had better survival rates (<it>p </it>= 0.001) after adjusting for comorbidities, hospital, and treatment modality. When analyzed by propensity score, the adjusted 10-year survival rate differed significantly between patients treated by high-volume physicians and patients treated by low/medium-volume physicians (75% <it>vs</it>. 61%; <it>p </it>< 0.001).</p> <p>Conclusions</p> <p>Our data confirm a positive volume-outcome relationship for NPC. After adjusting for differences in the case mix, our analysis found treatment of NPC by high-volume physicians improved 10-year survival rate.</p

    In Situ Measurement of the Junction Temperature of Light Emitting Diodes Using a Flexible Micro Temperature Sensor

    Get PDF
    This investigation aimed to fabricate a flexible micro resistive temperature sensor to measure the junction temperature of a light emitting diode (LED). The junction temperature is typically measured using a thermal resistance measurement approach. This approach is limited in that no standard regulates the timing of data capture. This work presents a micro temperature sensor that can measure temperature stably and continuously, and has the advantages of being lightweight and able to monitor junction temperatures in real time. Micro-electro-mechanical-systems (MEMS) technologies are employed to minimize the size of a temperature sensor that is constructed on a stainless steel foil substrate (SS-304 with 30 μm thickness). A flexible micro resistive temperature sensor can be fixed between the LED chip and the frame. The junction temperature of the LED can be measured from the linear relationship between the temperature and the resistance. The sensitivity of the micro temperature sensor is 0.059 ± 0.004 Ω/°C. The temperature of the commercial CREE® EZ1000 chip is 119.97 °C when it is thermally stable, as measured using the micro temperature sensor; however, it was 126.9 °C, when measured by thermal resistance measurement. The micro temperature sensor can be used to replace thermal resistance measurement and performs reliably
    corecore