30 research outputs found

    Changes of Radial Diffusivity and Fractional Anisotopy in the Optic Nerve and Optic Radiation of Glaucoma Patients

    Get PDF
    Purpose of this study was to evaluate with diffusion-tensor imaging (DTI) changes of radial diffusivity (RD) and fractional anisotropy (FA) in the optic nerve (ON) and optic radiation (OR) in glaucoma and to determine whether changes in RD and FA correlate with disease severity. Therefore, glaucoma patients and controls were examined using 3T. Regions of interest were positioned on RD and FA maps, and mean values were calculated for ON and OR and correlated with optic nerve atrophy and reduced spatial-temporal contrast sensitivity (STCS) of the retina. We found, that RD in glaucoma patients was significantly higher in the ON (0.74 ± 0.21 versus 0.58 ± 0.17·10−3 mm2 s−1; P < 0.05) and OR (0.79 ± 0.23 versus 0.62 ± 0.14·10−3 mm2 s−1; P < 0.05) compared to controls. Aside, FA was significantly decreased (0.48 ± 0.15 versus 0.66 ± 0.12 and 0.50 ± 0.20 versus 0.66 ± 0.11; P < 0.05). Hereby, correlation between changes in RD/FA and optic nerve atrophy/STCS was observed (r > 0.77). In conclusion, DTI at 3 Tesla allows robust RD and FA measurements in the ON and OR. Hereby, the extent of RD increase and FA decrease in glaucoma correlate with established ophthalmological examinations

    Superficial siderosis as a rare cause of visual and auditory pseudohallucinations: a case report

    No full text
    Background!#!Superficial siderosis is a rare disease involving hemosiderin deposits on the surface of brain or spinal cord that are thought to cause clinical symptoms, which usually consist of cranial nerve dysfunction, cerebellar ataxia, or myelopathy. Pseudohallucinations have been described as the patient being aware of the nonreality of hallucination-like phenomena. Data on pseudohallucinations of cerebral somatic origin are sparse. We present a case of auditory and visual pseudohallucinations due to superficial siderosis. Siderosis was diagnosed using cerebrospinal fluid analysis and magnetic resonance imaging as part of the clinical routine for newly emerged psychiatric symptoms.!##!Case presentation!#!An 84-year-old white/european female presented to our hospital with no prior history of psychiatric or neurological disease and no history of trauma. She reported seeing things and hearing voices singing to her for some days. She was aware these phenomena were not real (pseudohallucinations). On examination, no relevant abnormalities were detected. Cerebrospinal fluid analysis showed elevated ferritin. Magnetic resonance imaging with susceptibility-weighted sequences revealed diffuse superficial siderosis in several parts of the brain, among other occipital and temporal gyri. The pseudohallucinations resolved with a risperidone regime. The patient was treated with rivaroxaban because of atrial fibrillation. Potentially elevating the risk of further hemorrhage, this therapy was discontinued, and an atrial appendage occlusion device was implanted.!##!Conclusion!#!We report the first case of pseudohallucinations in superficial siderosis. The risk of missing this diagnosis can be reduced by applying a standardized diagnostic pathway for patients presenting with the first episode of psychiatric symptoms. Somatic and potentially treatable causes should not be missed because they might lead to unnecessary treatments, stigmatization, and legal restrictions of self-determination, especially for elderly people

    Irreversible brain damage caused by methamphetamine

    Get PDF
    Methamphetamine is an addictive scene substance usage of which is increasing rapidly. While methamphetamine often causes neuropsychiatric symptoms like anxiety, psychosis and hallucinations, reports of structural ongoing cerebral alterations are rare. We here report a case of this kind of damage caused through methamphetamine use

    Influence of different reconstruction parameters in the visualization of intracranial stents using C-arm flat panel CT angiography: experience in an animal model

    No full text
    Background C-arm flat panel computed tomography angiography (CA-CTA) is a relatively new imaging modality. Consequently, knowledge about postprocessing parameters and their influence on image quality is still limited, especially for the visualization of implanted microstents. Purpose To optimize reconstruction parameters by evaluating the influence of these different parameters for CA-CTA visualization of microstents in an animal model. Material and Methods Eleven microstents were implanted within the left common carotid artery of 11 New Zealand white rabbits. Both CA-CTA, using intra-venous delivery of contrast material, and conventional digital subtraction angiography (DSA) was performed. CA-CTA datasets were reconstructed using three different image characteristics (normal, sharp, smooth). Two experienced neuroradiologists evaluated the image quality and performed measurements of inner and outer stent diameters as well as measurements of the lumen area. Results Stent deployment was performed successfully in all animals. Inter-observer correlation coefficient for all measurements was high (r = 0.87–0.92). Lumen area and inner stent diameter were significantly smaller in image characteristic “smooth” (P < 0.01) than in “sharp” and “normal”. Outer stent diameter was larger in “smooth” than in “sharp” and “normal” (P < 0.01). Stent strut size was significantly wider using image characteristic “smooth”. “Sharp” and “normal” compared best to DSA, with “sharp” providing the closest match to DSA measurements, with the trade-off of significantly more noise than in the “normal” reconstructions. Conclusion The use of different image characteristics in the postprocessing of CA-CTA datasets has an influence on the visualization of implanted stents. Image characteristic “sharp” and “normal” compared best to DSA

    Flat-detector computed tomography evaluation in an experimental animal aneurysm model after endovascular treatment: A pilot study

    No full text
    We compared flat-detector computed tomography angiography (FD-CTA) to multislice computed tomography (MS-CTA) and digital subtracted angiography (DSA) for the visualization of experimental aneurysms treated with stents, coils or a combination of both. In 20 rabbits, aneurysms were created using the rabbit elastase aneurysm model. Seven aneurysms were treated with coils, seven with coils and stents, and six with self-expandable stents alone. Imaging was performed by DSA, MS-CTA and FD-CTA immediately after treatment. Multiplanar reconstruction (MPR) was performed and two experienced reviewers compared aneurysm/coil package size, aneurysm occlusion, stent diameters and artifacts for each modality. In aneurysms treated with stents alone, the visualization of the aneurysms was identical in all three imaging modalities. Residual aneurysm perfusion was present in two cases and visible in DSA and FD-CTA but not in MS-CTA. The diameter of coil-packages was overestimated in MS-CT by 56% and only by 16% in FD-CTA compared to DSA (p < 0.05). The diameter of stents was identical for DSA and FD-CTA and was significantly overestimated in MS-CTA (p < 0.05). Beam/metal hardening artifacts impaired image quality more severely in MS-CTA compared to FD-CTA. MS-CTA is impaired by blooming and beam/metal hardening artifacts in the visualization of implanted devices. There was no significant difference between measurements made with noninvasive FD-CTA compared to gold standard of DSA after stenting and after coiling/stent-assisted coiling of aneurysms. FD-CTA may be considered as a non-invasive alternative to the gold standard 2D DSA in selected patients that require follow up imaging after stenting

    Optimized Flat-Detector CT in Stroke Imaging: Ready for First-Line Use?

    No full text
    Background: Using flat-detector CT (FD-CT) for stroke imaging has the advantage that both diagnostic imaging and endovascular therapy can be performed directly within the Angio Suite without any patient transfer and time delay. Thus, stroke management could be speeded up significantly, and patient outcome might be improved. But as precondition for using FD-CT as primary imaging modality, a reliable exclusion of intracranial hemorrhage (ICH) has to be possible. This study aimed to investigate whether optimized native FD-CT, using a newly implemented reconstruction algorithm, may reliably detect ICH in stroke patients. Additionally, the potential to identify ischemic changes was evaluated. Methods: Cranial FD-CT scans were obtained in 102 patients presenting with acute ischemic stroke (n = 32), ICH (n = 45) or transient ischemic attack (n = 25). All scans were reconstructed with a newly implemented half-scan cone-beam algorithm. Two experienced neuroradiologists, unaware of clinical findings, evaluated independently the FD-CTs screening for hemorrhage or ischemic signs. The findings were correlated to CT, and rater and inter-rater agreement was assessed. Results: FD-CT demonstrated high sensitivity (95-100%) and specificity (100%) in detecting intracerebral and intraventricular hemorrhage (IVH). Overall, interobserver agreement (κ = 0.92) was almost perfect and rater agreement to CT highly significant (r = 0.81). One infratentorial ICH and 10 or 11 of 22 subarachnoid hemorrhages (SAHs) were missed of whom 7 were perimesencephalic. The sensitivity for detecting acute ischemic signs was poor in blinded readings (0 or 25%, respectively). Conclusions: Optimized FD-CT, using a newly implemented reconstruction algorithm, turned out as a reliable tool for detecting supratentorial ICH and IVH. However, detection of infratentorial ICH and perimesencephalic SAH is limited. The potential of FD-CT in detecting ischemic changes is poor in blinded readings. Thus, plain FD-CT seems insufficient as a standalone modality in acute stroke, but within a multimodal imaging approach primarily using the FD technology, native FD-CT seems capable to exclude reliably supratentorial hemorrhage. Currently, FD-CT imaging seems not yet ready for wide adoption, replacing regular CT, and should be reserved for selected patients. Furthermore, prospective evaluations are necessary to validate this approach in the clinical setting

    Flow-diverting stents allow efficient treatment of unruptured, intradural dissecting aneurysms of the vertebral artery: An explanatory approach using in vivo flow analysis

    No full text
    Object Our study aimed to evaluate the efficiency of flow-diverting stents (FDS) in treating unruptured, intradural dissecting aneurysms of the vertebral artery (VADAs). Additionally, the effect of FDS on the aneurysmal flow pattern was investigated by performing in vivo flow analysis using parametric color coding (PCC). Methods We evaluated 11 patients with unruptured, intradural VADAs, treated with FDS. Pre- and postinterventional DSA-series were postprocessed by PCC, and time-density curves were calculated. The parameters aneurysmal inflow-velocity, outflow-velocity and relative time-to-peak (rTTP) were calculated. Pre- and postinterventional values were compared and correlated with the occlusion rate after six months. Results Follow-up DSA detected 10 aneurysms occluded, meaning an occlusion rate of 91%. No procedure-related morbidity and mortality was found. Flow analyses revealed a significant reduction of aneurysmal inflow- velocity and prolongation of rTTP after FDS deployment. Concerning aneurysm occlusion, the postinterventional outflow-velocity turned out to be a marginally statistically significant predictor. A definite threshold value (–0.7 density change/s) could be determined for the outflow-velocity that allows prediction of complete aneurysm occlusion with high sensitivity and specificity (100%). Conclusions Using FDS can be considered an efficient and safe therapy option in treating unruptured, intradural VADA. From in vivo flow analyses the postinterventional aneurysmal outflow-velocity turned out to be a potential predictor for later complete aneurysm occlusion. Here, it might be possible to determine a threshold value that allows prediction of aneurysm occlusion with high specificity and sensitivity. As fast, applicable and easy-to-handle tool, PCC could be used for procedural monitoring and might contribute to further treatment optimization

    Stent-Assisted Coiling Using Leo+ Baby Stent

    No full text
    Background!#!Stent-assisted coiling is well-established for treatment of cerebral aneurysms. The technique enables treatment of wide-neck, bifurcation and recurrent aneurysms with high packing rates. While described in extenso for laser cut stents, the results of patients treated with the Leo+ Baby (Balt, Montmorency, France) braided microstent are presented.!##!Material and methods!#!Patients were included if treated with a Leo+ Baby and with digital subtraction angiography (DSA) follow-up available of at least 6 months. Data were evaluated for successful deployment, aneurysm occlusion according to the modified Raymond-Roy classification (MRRC), stent patency and procedure-related morbidity and mortality.!##!Results!#!A total of 81 patients were included and Leo+ Baby deployment was successful in all cases. Coils were used in 80 cases. In 1 case 2 stents were used stent-in-stent without additional coiling. Initial aneurysm occlusion rates were MRRC!##!Conclusion!#!The results confirm that stent-assisted coiling with the Leo+ Baby stent is safe and efficient for treatment of wide neck or recurrent cerebral aneurysms. Spontaneous progressive aneurysm occlusion over 6 months supports the theory of considerable flow-modulating effects of Leo+ Baby
    corecore